David McIntyre

David McIntyre

Auto-generated profile, based on publicly available information

David McIntyre

Department of Biomedical Engineering, Boston University, Boston, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
ALAli Lashkaripour
Ali Lashkaripour
CRChristopher Rodriguez
Christopher Rodriguez
NMNoushin Mehdipour
Noushin Mehdipour
RMRizki Mardian
Rizki Mardian
DMDavid McIntyre
David McIntyre
DDDouglas Densmore
Douglas Densmore
Droplet-based microfluidic devices hold immense potential in becoming inexpensive alternatives to existing screening platforms across life science applications, such as enzyme discovery and early cancer detection. However, the lack of a predictive understanding of droplet generation makes engineering a droplet-based platform an iterative and resource-intensive process. We present a web-based tool, DAFD, that predicts the performance and enables design automation of flow-focusing droplet generators. We capitalize on machine learning algorithms to predict the droplet diameter and rate with a mean absolute error of less than 10 μm and 20 Hz. This tool delivers a user-specified performance within 4.2% and 11.5% of the desired diameter and rate. We demonstrate that DAFD can be extended by the community to support additional fluid combinations, without requiring extensive machine learning knowledge or large-scale data-sets. This tool will reduce the need for microfluidic expertise and design iterations and facilitate adoption of microfluidics in life sciences.

29 July 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
DMDavid McIntyre
David McIntyre
ALAli Lashkaripour
Ali Lashkaripour
PFPolly Fordyce
Polly Fordyce
DDDouglas Densmore
Douglas Densmore
In this review article, we surveyed the applications of machine learning in microfluidic design and microfluidic control.

2 January 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
ALAli Lashkaripour
Ali Lashkaripour
DMDavid P. McIntyre
David P. McIntyre
SCSuzanne G. K. Calhoun
Suzanne G. K. Calhoun
KKKarl Krauth
Karl Krauth
DDDouglas M. Densmore
Douglas M. Densmore
PFPolly Fordyce
Polly Fordyce
Droplet microfluidics enables kHz screening of picoliter samples at a fraction of the cost of other high-throughput approaches. However, generating stable droplets with desired characteristics typically requires labor-intensive empirical optimization of device designs and flow conditions that limit adoption to specialist labs. Here, we compile a comprehensive droplet dataset and use it to train machine learning models capable of accurately predicting device geometries and flow conditions required to generate stable aqueous-in-oil and oil-in-aqueous single and double emulsions from 15 to 250 μm at rates up to 12000 Hz for different fluids commonly used in life sciences. Blind predictions by our models for as-yet-unseen fluids, geometries, and device materials yield accurate results, establishing their generalizability. Finally, we generate an easy-to-use design automation tool that yield droplets within 3 μm (<8%) of the desired diameter, facilitating tailored droplet-based platforms and accelerating their utility in life sciences.

1 September 2020 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DMDavid McIntyre
David McIntyre
ALAli Lashkaripour
Ali Lashkaripour
DDDouglas Densmore
Douglas Densmore
Electrode integration with off-the-shelf conductive ink provides a rapid and cost-effective method to develop sophisticated microfluidic prototypes in thermoplastics.

17 June 2022 in SLAS Technology
Verified
Journal Article
Open access
LLLena Landaverde
Lena Landaverde
DMDavid McIntyre
David McIntyre
JRJames Robson
James Robson
DFDany Fu
Dany Fu
LOLuis Ortiz
Luis Ortiz
CKCatherine Klapperich
Catherine Klapperich
In 2019, the first cases of SARS-CoV-2 were detected in Wuhan, China, and by early 2020 the first cases were identified in the United States. SARS-CoV-2 infections increased in the US causing many states to implement stay-at-home orders and additional safety precautions to mitigate potential outbreaks. As policies changed throughout the pandemic and restrictions lifted, there was an increase in demand for COVID-19 testing which was costly, difficult to obtain, or had long turn-around times. Some academic institutions, including Boston University (BU), created an on-campus COVID-19 screening protocol as part of a plan for the safe return of students, faculty, and staff to campus with the option for in-person classes. At BU, we put together an automated high-throughput clinical testing laboratory with the capacity to run 45,000 individual tests weekly by Fall of 2020, with a purpose-built clinical testing laboratory, a multiplexed reverse transcription PCR (RT-qPCR) test, robotic instrumentation, and trained staff. There were many challenges including supply chain issues for personal protective equipment and testing materials in addition to equipment that were in high demand. The BU Clinical Testing Laboratory (CTL) was operational at the start of Fall 2020 and performed over 1 million SARS-CoV-2 PCR tests during the 2020-2021 academic year.

26 October 2023 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DMDavid McIntyre
David McIntyre
ALAli Lashkaripour
Ali Lashkaripour
DADiana Arguijo
Diana Arguijo
PFPolly Fordyce
Polly Fordyce
DDDouglas Densmore
Douglas Densmore
Droplet generation is a fundamental component of droplet microfluidics, compartmentalizing biological or chemical systems within a water-in-oil emulsion. As adoption of droplet microfluidics expands beyond expert labs or integrated devices, quality metrics are needed to contextualize the performance capabilities, improving the reproducibility and efficiency of operation. Here, we present two quality metrics for droplet generation: performance versatility, the operating range of a single device, and stability, the distance of a single operating point from a regime change. Both metrics were characterized in silico and validated experimentally using machine learning and rapid prototyping. These metrics were integrated into a design automation workflow, DAFD 2.0, which provides users with droplet generators of a desired performance that are versatile or flow stable. Versatile droplet generators with stable operating points accelerate the development of sophisticated devices by facilitating integration of other microfluidic components and improving the accuracy of design automation tools.