13 December 2012 in Magnetic Resonance in Medicine
Purpose: This study aimed to quantitatively investigate two main magnetization transfer effects at low B1: the nuclear Overhauser enhancement (NOE) and amide proton transfer in the human brain at 7 T.Methods: The magnetization transfer effects in the human brain were characterized using a four‐pool proton model, which consisted of bulk water, macromolecules, an amide group of mobile proteins and peptides, and NOE‐related protons resonating upfield. The pool sizes, exchange rates, and relaxation times of these proton pools were investigated quantitatively by fitting, and the net signals of amide proton transfer and NOE were simulated based on the fitted parameters.Results: The results showed that the four‐pool model fitted the experimental data quite well, and the NOE effects in human brain at 7 T had a broad spectrum distribution. The NOE effects peaked at a B1 of ∼ 1–1.4 μT and were significantly stronger in the white matter than in the gray matter, corresponding to a pool‐size ratio ∼ 2:1. As the amide proton transfer effect was relatively small compared with the NOE effects, magnetization transfer asymmetry analysis yielded an NOE‐dominated contrast in the healthy human brain in this range of B1.Conclusion: These findings are important to identify the source of NOE effects and to quantify amide proton transfer effects in human brain at 7 T. Magn Reson Med, 70:1070–1081, 2013.
1 November 2015 in NeuroImage
12 July 2022 in Magnetic Resonance in Medicine
TGthe ISMRMPerfusion Study Group
the ISMRMPerfusion Study Group
+10
This review article provides an overview of the current status of velocity‐selective arterial spin labeling (VSASL) perfusion MRI and is part of a wider effort arising from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. Since publication of the 2015 consensus paper on arterial spin labeling (ASL) for cerebral perfusion imaging, important advancements have been made in the field. The ASL community has, therefore, decided to provide an extended perspective on various aspects of technical development and application. Because VSASL has the potential to become a principal ASL method because of its unique advantages over traditional approaches, an in‐depth discussion was warranted. VSASL labels blood based on its velocity and creates a magnetic bolus immediately proximal to the microvasculature within the imaging volume. VSASL is, therefore, insensitive to transit delay effects, in contrast to spatially selective pulsed and (pseudo‐) continuous ASL approaches. Recent technical developments have improved the robustness and the labeling efficiency of VSASL, making it a potentially more favorable ASL approach in a wide range of applications where transit delay effects are of concern. In this review article, we (1) describe the concepts and theoretical basis of VSASL; (2) describe different variants of VSASL and their implementation; (3) provide recommended parameters and practices for clinical adoption; (4) describe challenges in developing and implementing VSASL; and (5) describe its current applications. As VSASL continues to undergo rapid development, the focus of this review is to summarize the fundamental concepts of VSASL, describe existing VSASL techniques and applications, and provide recommendations to help the clinical community adopt VSASL.
14 November 2017 in Journal of Magnetic Resonance Imaging
4 November 2019 in Journal of Magnetic Resonance Imaging
8 February 2019 in Magnetic Resonance in Medicine