Laboratory of FMRI Technology (LOFT), USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Ave, Los Angeles, CA 90033, USA
Dr. Xingfeng Shao
Laboratory of FMRI Technology (LOFT), USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Ave, Los Angeles, CA 90033, USA
Purpose: To present a pulse sequence and mathematical models for quantification of blood–brain barrier water exchange and permeability.Methods: Motion‐compensated diffusion‐weighted (MCDW) gradient‐and‐spin echo (GRASE) pseudo‐continuous arterial spin labeling (pCASL) sequence was proposed to acquire intravascular/extravascular perfusion signals from five postlabeling delays (PLDs, 1590–2790 ms). Experiments were performed on 11 healthy subjects at 3 T. A comprehensive set of perfusion and permeability parameters including cerebral blood flow (CBF), capillary transit time (τc), and water exchange rate (kw) were quantified, and permeability surface area product (PSw), total extraction fraction (Ew), and capillary volume (Vc) were derived simultaneously by a three‐compartment single‐pass approximation (SPA) model on group‐averaged data. With information (i.e., Vc and τc) obtained from three‐compartment SPA modeling, a simplified linear regression of logarithm (LRL) approach was proposed for individual kw quantification, and Ew and PSw can be estimated from long PLD (2490/2790 ms) signals. MCDW‐pCASL was compared with a previously developed diffusion‐prepared (DP) pCASL sequence, which calculates kw by a two‐compartment SPA model from PLD = 1800 ms signals, to evaluate the improvements.Results: Using three‐compartment SPA modeling, group‐averaged CBF = 51.5/36.8 ml/100 g/min, kw = 126.3/106.7 min−1, PSw = 151.6/93.8 ml/100 g/min, Ew = 94.7/92.2%, τc = 1409.2/1431.8 ms, and Vc = 1.2/0.9 ml/100 g in gray/white matter, respectively. Temporal SNR of MCDW‐pCASL perfusion signals increased 3‐fold, and individual kw maps calculated by the LRL method achieved higher spatial resolution (3.5 mm3 isotropic) as compared with DP pCASL (3.5 × 3.5 × 8 mm3).Conclusion: MCDW‐pCASL allows visualization of intravascular/extravascular ASL signals across multiple PLDs. The three‐compartment SPA model provides a comprehensive measurement of blood–brain barrier water dynamics from group‐averaged data, and a simplified LRL method was proposed for individual kw quantification.
4 November 2019 in Journal of Magnetic Resonance Imaging
Purpose: To optimize pseudo‐continuous arterial spin labeling (pCASL) for 7 T, and to further improve the labeling efficiency with parallel RF transmission transmit B1 () shimming.Methods: pCASL parameters were optimized based on field distributions at 7 T with simulation. To increase labeling efficiency, the amplitude at inflowing arteries was increased with parallel RF transmission shimming. The “indv‐shim” with shimming weights calculated for each individual subject, and the “univ‐shim” with universal weights calculated on a group of 12 subjects, were compared with circular polarized (CP) shim. The optimized pCASL sequences with three shimming modes (indv‐shim, univ‐shim, and CP‐shim) were evaluated in 6 subjects who underwent two repeated scans 24 hours apart, along with a pulsed ASL sequence. Quantitative metrics including mean amplitude, perfusion, and intraclass correlation coefficient were calculated. The optimized 7T pCASL was compared with standard 3T pCASL on 5 subjects, using spatial SNR and temporal SNR.Results: The optimal pCASL parameter set (RF duration/gap = 300/250 us, ) achieved robust perfusion measurement in the presence of inhomogeneities. Both indv‐shim and univ‐shim significantly increased amplitude compared with CP‐shim in simulation and in vivo experiment (P < .01). Compared with CP‐shim, perfusion signal was increased by 9.5% with indv‐shim (P < .05) and by 5.3% with univ‐shim (P = .35). All three pCASL sequences achieved fair to good repeatability (intraclass correlation coefficient ≥ 0.5). Compared with 3T pCASL, the optimized 7T pCASL achieved 78.3% higher spatial SNR and 200% higher temporal SNR.Conclusion: The optimized pCASL achieved robust perfusion imaging at 7 T, while both indv‐shim and univ‐shim further increased labeling efficiency.
The blood-brain barrier (BBB) plays a pivotal role in protecting the central nervous system (CNS), and shielding it from potential harmful entities. A natural decline of BBB function with aging has been reported in both animal and human studies, which may contribute to cognitive decline and neurodegenerative disorders. Limited data also suggest that being female may be associated with protective effects on BBB function. Here, we investigated age and sex-dependent trajectories of perfusion and BBB water exchange rate (kw) across the lifespan in 186 cognitively normal participants spanning the ages of 8–92 years old, using a non-invasive diffusion-prepared pseudo-continuous arterial spin labeling (DP-pCASL) MRI technique. We found that the pattern of BBB kw decline with aging varies across brain regions. Moreover, results from our DP-pCASL technique revealed a remarkable decline in BBB kw beginning in the early 60 s, which was more pronounced in males. In addition, we observed sex differences in parietal and temporal regions. Our findings provide in vivo results demonstrating sex differences in the decline of BBB function with aging, which may serve as a foundation for future investigations into perfusion and BBB function in neurodegenerative and other brain disorders.