Cao Van Hiep

Cao Van Hiep

Auto-generated profile, based on publicly available information

Cao Van Hiep

Military Institute of Chemical and Environmental Engineering (MICEE), Hanoi, Vietnam

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
VCVan Hiep Cao
Van Hiep Cao
TDTien Hung Dinh
Tien Hung Dinh
TNThi Thoa Nguyen
Thi Thoa Nguyen
KNKhanh Hung Nguyen
Khanh Hung Nguyen
DPDinh Khang Pham
Dinh Khang Pham
Tien-Anh NguyenTien-Anh Nguyen
Tien-Anh Nguyen

11 May 2022 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CHCao Van Hiep
Cao Van Hiep
DHDinh Tien Hung
Dinh Tien Hung
NNNgoc Anh Nguyen
Ngoc Anh Nguyen
NGNguyen Ninh Giang
Nguyen Ninh Giang
PKPham Dinh Khang
Pham Dinh Khang
PCPhan Van Chuan
Phan Van Chuan
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.

11 November 2021 in Journal of Military Science and Technology
Verified
Journal Article
Closed access
CHCao Van Hiep
Cao Van Hiep
This paper presents the characteristics determination process of the large-size Polyvinyl Toluene (PVT) scintillation detectors using MCNP5 simulation code. The energy spectra using a 137Cs calibration source, absolute efficiency in the energy range of 50 ÷ 3000 keV, and the angular response of the EJ-200 50×50×5 cm3 and 25×25×5cm3 are investigated. The simulated energy spectra are in good agreement with the experimental spectra. The results of determining the absolute efficiency show that the EJ-200 50×50×5 cm3 and 25×25×5cm3 plastic detectors have detection efficiencies of 16,3% and 9,2%, respectively, at 10cm source-to-detector distance, and down to 0,6% and 0,17% at 100 cm source-to-detector distance. The angular responses of the detectors show that the detection efficiency value reached ≥ 90% of the maximum value with the incident angle less than 5π/6. The results can be applied in the process of design optimization of plastic-based radiation portal monitors.