Dinh Tien Hung

Dinh Tien Hung

Auto-generated profile, based on publicly available information

Dinh Tien Hung

Military Institute of Chemical and Environmental Engineering (MICEE), Hanoi, Vietnam

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
VCVan Hiep Cao
Van Hiep Cao
TDTien Hung Dinh
Tien Hung Dinh
TNThi Thoa Nguyen
Thi Thoa Nguyen
KNKhanh Hung Nguyen
Khanh Hung Nguyen
DPDinh Khang Pham
Dinh Khang Pham
Tien-Anh NguyenTien-Anh Nguyen
Tien-Anh Nguyen

11 May 2022 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CHCao Van Hiep
Cao Van Hiep
DHDinh Tien Hung
Dinh Tien Hung
NNNgoc Anh Nguyen
Ngoc Anh Nguyen
NGNguyen Ninh Giang
Nguyen Ninh Giang
PKPham Dinh Khang
Pham Dinh Khang
PCPhan Van Chuan
Phan Van Chuan
This article proposes a multi-label classification model using an artificial neural network (ANN) to identify both an individual and a mixture of radionuclides in gamma spectra obtained from a $250\times 250\times 50$ -mm 3 EJ-200 plastic scintillation detector. This model is evaluated under the scenario applied to pedestrian radiation portal monitors (RPMs) to judge how well it works in practice. The simulated and measured gamma of 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ radioactive sources and background are used to generate the training dataset. Measurement data with varying source-to-detector distances, shielding thicknesses, and incidence angles are also taken into account. The experimental results show that the mean value of the accuracy can be achieved at about 98.8% and 94.9% for single- and multi-isotope identification, respectively. In addition, the model can well precisely recognize radionuclides in the gamma spectrum whose gain shift is up to 10%. The dependence of the true positive (TP) rate on the count quality factors of individual radionuclides, which was defined as the ratio between the net count rate and its associated uncertainty, is examined. The detection sensitivities, defined as the minimum count quality factor to obtain a TP rate of 95%, for 241 Am, 133 Ba, 137 Cs, 60 Co, 152 Eu, and $^{131}\text{I}$ are 8.90, 11.86, 8.96, 8.21, 12.54, and 11.89, respectively. With such encouraging results, the proposed model should be a useful technique for radionuclide recognition.

2 March 2020 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
DHDinh Tien Hung
Dinh Tien Hung
CHCao Van Hiep
Cao Van Hiep
PKPham Dinh Khang
Pham Dinh Khang
NHNguyen Xuan Hai
Nguyen Xuan Hai
NNNgoc Anh Nguyen
Ngoc Anh Nguyen
VPV. Pham
V. Pham
Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

27 August 2020 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
DHDinh Tien Hung
Dinh Tien Hung
CHCao Van Hiep
Cao Van Hiep
PKPham Dinh Khang
Pham Dinh Khang
NHNguyen Xuan Hai
Nguyen Xuan Hai
DTDuc-Tan Tran
Duc-Tan Tran
Tien-Anh NguyenTien-Anh Nguyen
Tien-Anh Nguyen
This work presents a high-resolution, high-confidence, and high-temperature-stabilization prototype environmental radiation monitoring system (ERMS) with integrated digital filter, peak-finding algorithms, and real-time analyses. Through measuring 137Cs and 60Co radiation sources with the same NaI(Tl) detector, the features of the digital multi-channel analyzer (DMCA) in our system, including throughput, energy resolution, and peak shape, were compared with those of a commercial instrument, namely, the DSPEC jr 2.0 from ORTEC, USA. The results indicate that the FWHM and peak heights obtained with our DMCA are better than those obtained with the DSPEC jr 2.0 up to 12%. The ERMS also integrates a solar power supply, multimodal data transmission, and a weather channel, thus facilitating its deployment in boundary areas or far islands for monitoring and forecasting radioactive propagation. Therefore, the proposed configuration system is highly promising in terms of performance and low cost of maintenance.

29 January 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
VQVu Thi Thanh Quy
Vu Thi Thanh Quy
PCPhan Van Chuan
Phan Van Chuan
NNNgoc Anh Nguyen
Ngoc Anh Nguyen
NHNguyen Quang Hung
Nguyen Quang Hung
DHDinh Tien Hung
Dinh Tien Hung
NHNguyen Xuan Hai
Nguyen Xuan Hai
An end-to-end simulation and experimental validation framework is presented for compact neutron detectors based on EJ-276 plastic scintillators coupled to silicon photomultipliers. The workflow combines Geant4 optical-photon transport with a physics-based signal-formation model to predict preamplifier-level voltage waveforms. Benchmarking with a cobalt-60 source demonstrates close waveform agreement after baseline subtraction and peak-time alignment, with high similarity over 100-500 ns (correlation r = 0.997 and normalized root mean square error nRMSE= 2.8%). The model preserves key pulse observables, including peak amplitude (0.5% difference), peak timing (about 1 ns), and pulse integral (0.34% difference), while the residual mismatch is mainly confined to fast/tail dynamics (slightly faster rise and a shorter effective decay constant in simulation). The validated model is then applied to eight geometries to quantify trade-offs between neutron detection efficiency and neutron–gamma separation. Using figure of merit, intrinsic detection efficiency, and misclassification rate, we identify that designs near Ø50 mm × 50 mm balance discrimination and efficiency for compact, field-deployable instruments. The proposed approach enables predictive optimization of pulse-shape discrimination capable plastic-scintillator detectors without iterative prototyping, and is readily extensible to other silicon photomultipliers based systems.