Sergei Vostrikov

Sergei Vostrikov

Auto-generated profile, based on publicly available information

Sergei Vostrikov

Department of Information Technology and Electrical Engineering (D-ITET), ETH Zrich, Zrich, Switzerland

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Applied Energy
Verified
Journal Article
Closed access
SVSergei Vostrikov
Sergei Vostrikov
ASAndrey Somov
Andrey Somov
PGPavel Gotovtsev
Pavel Gotovtsev

12 November 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SVSergei Vostrikov
Sergei Vostrikov
JTJosquin Tille
Josquin Tille
LBLuca Benini
Luca Benini
ACAndrea Cossettini
Andrea Cossettini
The need for continuous monitoring of cardiorespiratory activity, blood pressure, bladder, muscle motion analysis, and more, is pushing for research and development of wearable ultrasound devices. In this context, there is a critical need for highly configurable, energy-efficient wearable ultrasound systems with wireless access to raw data and long battery life. Previous exploratory works have primarily relied on bulky commercial research systems or custom-built prototypes with limited and narrowly-focused field applicability. This paper presents TINYPROBE, a novel multi-modal wearable ultrasound platform. TINYPROBE integrates a 32-channel ultrasound RX/TX frontend, including TX beamforming (64 V pp excitations, 16 delay profiles) and analog-to-digital conversion (up to 30 Msps, 10 bit), with a WiFi link (21.6 Mbps, UDP), for wireless raw data access, all in a compact (57 × 35 × 20 mm) and lightweight (35 g) design. Employing advanced power-saving techniques and optimized electronics design, TINYPROBE achieves a power consumption of < 1W for imaging modes (32 ch., 33 Hz) and < 1.3W for high-PRF Doppler mode (2 ch., 1400 Hz). This results in a state-of-the-art power efficiency of 44.9 mW/Mbps for wireless US systems, ensuring multi-hour operation with a compact 500 mAh Li-Po battery. We validate TINYPROBE as a versatile, general-purpose wearable platform in multiple in-vivo imaging scenarios, including muscle and bladder imaging, and blood flow velocity measurements.

1 July 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SVSergei Vostrikov
Sergei Vostrikov
MAMatteo Anderegg
Matteo Anderegg
LBLuca Benini
Luca Benini
ACAndrea Cossettini
Andrea Cossettini
Wearable ultrasound is a novel sensing approach that shows promise in multiple application domains, and specifically in hand gesture recognition. In fact, ultrasound enables to collect information from deep musculoskeletal structures at high spatiotemporal resolution and high signal-to-noise ratio, making it a perfect candidate to complement surface electromyography for improved accuracy performance and on-the-edge classification. However, existing wearable solutions for ultrasound-based gesture recognition are not sufficiently low-power for continuous, long-term operation. On top of that, practical hardware limitations of wearable ultrasound devices (limited power budget, reduced wireless throughput, restricted computational power) set the need for the compressed size of models for feature extraction and classification. To overcome these limitations, this paper presents a novel end-to-end approach for feature extraction from raw musculoskeletal ultrasound data suited for edge-computing, coupled with an armband for hand gesture recognition based on a truly wearable (12 cm2, 9 g), ultra-low power (16 mW) ultrasound probe. The proposed approach uses a 1D convolutional autoencoder to compress raw ultrasound data by 20× while preserving the main amplitude features of the envelope signal. The latent features of the autoencoder are used to train an XGBoost classifier for hand gesture recognition on datasets collected with a custom US armband, considering armband removal/repositioning in between sessions. Our approach achieves a classification accuracy of 96%. Furthermore, the proposed unsupervised feature extraction approach offers generalization capabilities for inter-subject use, as demonstrated by testing the pre-trained Encoder on a different subject and conducting post-training analysis, revealing that the operations performed by the Encoder are subject-independent. The autoencoder is also quantized to 8-bit integers and deployed on an ultra-low-power wearable ultrasound probe along with the XGBoost classifier, allowing for a gesture recognition rate ≥ 25 Hz and leading to 21% lower power consumption (at 30 FPS) compared to the conventional approach (raw data transmission and remote processing).

28 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SVSergei Vostrikov
Sergei Vostrikov
TIThorir Mar Ingolfsson
Thorir Mar Ingolfsson
SHSoley Hafthorsdottir
Soley Hafthorsdottir
CLChristoph Leitner
Christoph Leitner
Michele MagnoMichele Magno
Michele Magno
ACAndrea Cossettini
Andrea Cossettini
Measurement of muscle activity via wearable instrumentation is of great interest for medical and sport science applications: examples include the control of prostheses, robotics, or therapy and training. This article focuses on the measurement of pennation angles in lateral gastrocnemius (LG) muscles directly from raw ultrasound (US) data. We rely on a reduced number of channels (32) to demonstrate accurate and real-time-compatible predictions of pennation angles for low-power wearable US devices. B-mode images are reconstructed by means of a delay-and-sum beamformer, and an automated computer vision tool (AEPUS) is employed to perform annotations. The labels are then used as ground truth for training an XGBoost regressor based on statistical features extracted from raw US data. Feature importance analyses and deployment-oriented XGBoost model design allow reducing the memory footprint down to only 11 kB. Experimental verification demonstrates a root-mean-square error (RMSE) of 1.6°, comparable to manual annotations by experts. To evaluate the performance on a low-power embedded processor, the complete algorithm is implemented on a recently released RISC-V-based parallel low-power processor (GAP9, from Greenwaves Technologies). Experimental measurements show an inference time and energy consumption as low as 1.31 ms and 43.32 $\mu \text{J}$ , respectively, with an average power envelope of 33.14 mW and a peak power of only 44 mW. The achieved accuracy, low memory footprint, and low power demonstrate the feasibility of pennation angle measurements directly on the probe for resource-constrained smart wearable US devices with a small number of channels.

23 September 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
GSGiusy Spacone
Giusy Spacone
SVSergei Vostrikov
Sergei Vostrikov
VKVictor Kartsch
Victor Kartsch
SBSimone Benatti
Simone Benatti
LBLuca Benini
Luca Benini
ACAndrea Cossettini
Andrea Cossettini
Ultrasound-based Hand Gesture Recognition has gained significant attention in recent years. While static gesture recognition has been extensively explored, only a few works have tackled the task of movement regression for real-time tracking, despite its importance for the development of natural and smooth interaction strategies. In this paper, we demonstrate the regression of 3 hand-wrist Degrees of Freedom (DoFs) using a lightweight, A-mode-based, truly wearable US armband featuring four transducers and WULPUS, an ultra-low-power acquisition device. We collect US data, synchronized with an optical motion capture system to establish a ground truth, from 5 subjects. We achieve state-of-the-art performance with an average root-mean-squared-error (RMSE) of 7.32◦ ± 1.97◦ and mean-absolute-error (MAE) of 5.31◦ ± 1.42◦. Additionally, we demonstrate, for the first time, robustness with respect to transducer repositioning between acquisition sessions, achieving an average RMSE value of 11.11◦ ± 4.14◦ and a MAE of 8.46◦ ± 3.58◦. Finally, we deploy our pipeline on a real-time low-power microcontroller, showcasing the first instance of multi-DoF regression based on A-mode US data on an embedded device, with a power consumption lower than 30mW and end-to-end latency of ≈ 80 ms.

1 January 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
SVSergei Vostrikov
Sergei Vostrikov
FVFederico Villani
Federico Villani
CHCedric Hirschi
Cedric Hirschi
JLJinhao Lu
Jinhao Lu
JWJonas Welsch
Jonas Welsch
LBLuca Benini
Luca Benini