Jing Chen

Jing Chen

Auto-generated profile, based on publicly available information

Jing Chen

School of Control Science and Engineering, Dalian University of Technology, Dalian, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZLZhaolin Li
Zhaolin Li
PSPengcheng Sun
Pengcheng Sun
HHHui Huang
Hui Huang
WCWeicheng Cai
Weicheng Cai
XJXiaozheng Jiang
Xiaozheng Jiang
Huolin HuangHuolin Huang
Huolin Huang
Due to the frequent occurrence of marine oil spill accidents and related ecological pollution, online detection of oil-slick thickness is important. Fluorescence detection of oil slick has the advantages of high sensitivity and no need of reagent. Herein, a compact and sensitive fluorometer consisted of two metal capillary (MC), a UV LED and a linear variable filter (LVF), was developed for oil slick detection in a non-contact way. The two MCs are used to transmit UV light and collect fluorescence above the oil slick, respectively, and the angle between them is 45 degrees (V-shaped MCs). By employing MCs, the detection signal-to-noise ratio (SNR) can be improved by 34.5 times, and the limit of detection (LOD) of oil slick thickness is as low as 0.035 µm. The relationship between the fluorescence signal and the oil slick thickness features good linearity (R2 = 0.998) in a range of 0.035 ~ 20 µm. The spectrometer would be suitable for online monitoring marine oil spill.

22 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SZShuang Zeng
Shuang Zeng
JZJun-Hao Zhao
Jun-Hao Zhao
HHHui Huang
Hui Huang
WCWei-Cheng Cai
Wei-Cheng Cai
TSTao Sun
Tao Sun
JCJing Chen
Jing Chen
Currently, for fiber optic vibration sensors (FOVS), realizing high sensitivity (sub-μg) and high speed (~ kHz) simultaneously is still a challenge. Herein, a high speed and highly sensitive FOVS was demonstrated by using the liquid mass block (silicone oil), which can transmit the inertial force to all the direction inside the FOVS for omnidirectional sensing. Owing to the liquid nature of oil, the inertial force can be uniformly applied on the diaphragm without deteriorating its mechanical properties. The response magnitude of FOVS can be enhanced ~48 dB by employing the liquid mass block. Moreover, because without using any optical interference effect, precise control on the light wavelength and cavity length is no longer needed, which simplifies sensor fabrication and demodulation system for compact and low cost. An omnidirectional detection limit of 0.1 μg, a sensitivity of 3.2 V/g, and a resonance frequency of 2.7 kHz was realized for the FOVS.