Nandha Kumar

Nandha Kumar

Auto-generated profile, based on publicly available information

Nandha Kumar

Department of Electrical and Electronics Engineering PSNA College of Engineering & Technology, Dindigul TamilNadu, India

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2015 in Journal of Experimental & Theoretical Artificial Intelligence
Verified
Journal Article
Closed access
KJK. Arul Jeyaraj
K. Arul Jeyaraj
VRV. Rajasekaran
V. Rajasekaran
SKS.K. Nandha Kumar
S.K. Nandha Kumar
KCK. Chandrasekaran
K. Chandrasekaran
This paper presents Multi-objective Optimal Placement of Phasor measurement units (MOPP) to improve the performance of power system monitoring and control. It is proposed for achieving complete observability with a minimal number of phasor measurement units (PMUs) and maximising the voltage stability level of the system, simultaneously. As the above mentioned objectives are conflicting in nature, a fuzzified binary artificial bee colony algorithm is considered to solve the MOPP problem to offer a good tradeoff solution between the competing objectives. Here, fuzzy membership for each objective function is designed and proposed to decide the best solution of MOPP problem. Initially, weak buses are identified using the fast voltage stability index calculation for their close and reliable monitoring. This is done in order to prevent the outage of these buses. The conventional rule is used to minimise the number of PMUs and a new rule is proposed to maximise both the observability and voltage stability levels of the system. The efficiency of the artificial bee colony method is validated on IEEE 14, 30 and 57 bus test systems and it is verified by comparing the performance of proposed method with earlier works.

1 March 2015 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
KJK. Arul Jeyaraj
K. Arul Jeyaraj
VRV. Rajasekaran
V. Rajasekaran
SKS.K. Nandha Kumar
S.K. Nandha Kumar
KCK. Chandrasekaran
K. Chandrasekaran

1 January 2014 in Advances in Electrical and Computer Engineering
Verified
Journal Article
Open access
AKA. Kulanthaisamy
A. Kulanthaisamy
RVR. Vairamani
R. Vairamani
NKN. K. Karunamurthi
N. K. Karunamurthi
CKC. Koodalsamy
C. Koodalsamy
This paper presents a Multi- objective Optimal Placement of Phasor Measurement Units (MOPP) method in large electric transmission systems. It is proposed for minimizing the number of Phasor Measurement Units (PMUs) for complete system observability and maximizing the measurement redundancy of the system, simultaneously. The measurement redundancy means that number of times a bus is able to monitor more than once by PMUs set. A higher level of measurement redundancy can maximize the total system observability and it is desirable for a reliable power system state estimation. Therefore, simultaneous optimization of the two conflicting objectives are performed using a binary coded Artificial Bee Colony (ABC) algorithm. The complete observability of the power system is first prepared and then, single line loss contingency condition is considered to the main model. The efficiency of the proposed method is validated on IEEE 14, 30, 57 and 118 bus test systems. The valuable approach of ABC algorithm is demonstrated in finding the optimal number of PMUs and their locations by comparing the performance with earlier works

1 March 2018
Verified
Conference Paper
Closed access
AKA. Kalaivani
A. Kalaivani
SKS. K. Nandha Kumar
S. K. Nandha Kumar
A novel modified SEPIC DC-DC converter has designed to solar panel PV system is endorsed on view of work. proposed configuration has been considered as unification of Boost and SEPIC DC-DC converter. The proposed configuration needs only one power semi-conductor switch, lessening the voltage stress in this converter switch but then again also delivered a continuous input current. Added to that, the topology amplifying the high gain while related to classical SEPIC converter. Modified SEPIC has been integrated with perturb and observe algorithm. Characteristics of designed converter is illustrated by simulation results.

20 January 2015 in Automatika
Verified
Journal Article
Closed access
PDF file
NKNandha Kumar
Nandha Kumar
MRMuthukumar Ramraj
Muthukumar Ramraj
Power distribution systems must be very effective in power delivery. Utilities are continuously looking for recent technologies to enhance power delivery performance. The control of power loss is one of the most important issues directly related to system efficiency. Distribution system reconfiguration and optimal capacitor placement are the two most popular techniques adapted for the control of power loss. The techniques not only concentrate on power loss control but also control volt/var of the distribution system, and at the same time improve the system reliability and security. Former method is the process of changing the topology of distribution system by altering the open/closed status of switches to find a radial operating structure that minimizes the system real power loss while satisfying operating constraints. Later is the identification of optimal location and size of the capacitors with the objective of minimizing the power loss. This paper combines both reconfiguration and optimal capacitor placement for the effective optimization. Furthermore, it utilizes Opposition based Differential Evolution algorithm for efficient searching for the optimal solution. The effectiveness of the proposed approach is demonstrated by employing the feeder switching operation scheme to IEEE-33 bus Power Distribution systems. The proposed algorithm reduces the transmission loss and controls volt/var while satisfying power flow constraints.

1 October 2010
Verified
Conference Paper
Closed access
SKS.K. Nandha Kumar
S.K. Nandha Kumar
PRP. Renuga
P. Renuga
This paper proposes an application of Fast Voltage Stability Index (FVSI) to Reactive Power Planning (RPP) using Evolutionary Programming (EP). FVSI is used to identify the weak buses for the RPP problem which involves experimental process of voltage stability analysis based on the load variation. The point at which FVSI close to unity indicates the maximum possible connected load and the bus with minimum connected load is identified as the weakest bus at the point of bifurcation. The proposed approach has been used in the IEEE 30-bus system. Simulation results show considerable reduction in system losses and improvement of voltage stability with the use of FVSI for the RPP problem.