Avik Mukherjee

Avik Mukherjee

Auto-generated profile, based on publicly available information

Avik Mukherjee

Harvard Medical School, Department of Systems Biology, Boston, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2020 in Nature
Verified
Journal Article
Closed access
PDF file
MBMarkus Basan
Markus Basan
THTomoya Honda
Tomoya Honda
DCDimitris Christodoulou
Dimitris Christodoulou
MHManuel Hörl
Manuel Hörl
YCYu-Fang Chang
Yu-Fang Chang
USUwe Sauer
Uwe Sauer

10 March 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
JAJeffrey Abbott
Jeffrey Abbott
AMAvik Mukherjee
Avik Mukherjee
WWWenxuan Wu
Wenxuan Wu
TYTianyang Ye
Tianyang Ye
HJHan Sae Jung
Han Sae Jung
HPHongkun Park
Hongkun Park
Electrode-based impedance and electrochemical measurements can provide cell-biology information that is difficult to obtain using optical-microscopy techniques. Such electrical methods are non-invasive, label-free, and continuous, eliminating the need for fluorescence reporters and overcoming optical imaging's throughput/temporal resolution limitations. Nonetheless, electrode-based techniques have not been heavily employed because devices typically contain few electrodes per well, resulting in noisy aggregate readouts. Complementary metal-oxide-semiconductor (CMOS) microelectrode arrays (MEAs) have sometimes been used for electrophysiological measurements with thousands of electrodes per well at sub-cellular pitches, but only basic impedance mappings of cell attachment have been performed outside of electrophysiology. Here, we report on new field-based impedance mapping and electrochemical mapping/patterning techniques to expand CMOS-MEA cell-biology applications. The methods enable accurate measurement of cell attachment, growth/wound healing, cell–cell adhesion, metabolic state, and redox properties with single-cell spatial resolution (20 μm electrode pitch). These measurements allow the quantification of adhesion and metabolic differences of cells expressing oncogenes versus wild-type controls. The multi-parametric, cell-population statistics captured by the chip-scale integrated device opens up new avenues for fully electronic high-throughput live-cell assays for phenotypic screening and drug discovery applications.

21 November 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
SCShalaka Chitale
Shalaka Chitale
WWWenxuan Wu
Wenxuan Wu
AMAvik Mukherjee
Avik Mukherjee
HLHerbert Lannon
Herbert Lannon
PSPooja Suresh
Pooja Suresh
JAJeffrey Abbott
Jeffrey Abbott
High-content imaging for compound and genetic profiling is popular for drug discovery but limited to endpoint images of fixed cells. Conversely, electronic-based devices offer label-free, live cell functional information but suffer from limited spatial resolution or throughput. Here, we introduce a semiconductor 96-microplate platform for high-resolution, real-time impedance imaging. Each well features 4096 electrodes at 25 µm spatial resolution and a miniaturized data interface allows 8× parallel plate operation (768 total wells) for increased throughput. Electric field impedance measurements capture >20 parameter images including cell barrier, attachment, flatness, and motility every 15 min during experiments. We apply this technology to characterize 16 cell types, from primary epithelial to suspension cells, and quantify heterogeneity in mixed co-cultures. Screening 904 compounds across 13 semiconductor microplates reveals 25 distinct responses, demonstrating the platform’s potential for mechanism of action profiling. The scalability and translatability of this semiconductor platform expands high-throughput mechanism of action profiling and phenotypic drug discovery applications.

23 May 2024 in Nature Physics
Verified
Journal Article
Closed access
PDF file
SSSeverin Schink
Severin Schink
MPMark Polk
Mark Polk
EAEdward Athaide
Edward Athaide
AMAvik Mukherjee
Avik Mukherjee
CAConstantin Ammar
Constantin Ammar
MBMarkus Basan
Markus Basan

26 June 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
AMAvik Mukherjee
Avik Mukherjee
JEJade Ealy
Jade Ealy
YHYanqing Huang
Yanqing Huang
NBNina Catherine Benites
Nina Catherine Benites
MPMark Polk
Mark Polk
MBMarkus Basan
Markus Basan
Evolution of complex communities of coexisting microbes remains poorly understood. The long-term evolution experiment on Escherichia coli (LTEE) revealed the spontaneous emergence of stable coexistence of multiple ecotypes, which persisted for more than 14,000 generations of continuous evolution. Here, using a combination of experiments and computer simulations, we show that the emergence and persistence of this phenomenon can be explained by the combination of two interacting trade-offs, rooted in biochemical constraints: First, faster growth is enabled by higher fermentation and obligate acetate excretion. Second, faster growth results in longer lag times when utilizing acetate after glucose is depleted. This combination creates an ecological niche for a slower-growing ecotype, specialized in switching to acetate. These findings demonstrate that trade-offs can give rise to surprisingly complex communities with evolutionarily stable coexistence of multiple variants in even the simplest environments.

1 August 2014 in Development
Verified
Journal Article
Open access
PDF file
EMEurico Morais-de-Sá
Eurico Morais-de-Sá
AMAvik Mukherjee
Avik Mukherjee
NLNick Lowe
Nick Lowe
DJDaniel St Johnston
Daniel St Johnston
The Drosophila anterior-posterior axis is specified when the posterior follicle cells signal to polarise the oocyte, leading to the anterior/lateral localisation of the Par-6/aPKC complex and the posterior recruitment of Par-1, which induces a microtubule reorganisation that localises bicoid and oskar mRNAs. Here we show that oocyte polarity requires Slmb, the substrate specificity subunit of the SCF E3 ubiquitin ligase that targets proteins for degradation. The Par-6/aPKC complex is ectopically localised to the posterior of slmb mutant oocytes, and Par-1 and oskar mRNA are mislocalised. Slmb appears to play a related role in epithelial follicle cells, as large slmb mutant clones disrupt epithelial organisation, whereas small clones show an expansion of the apical domain, with increased accumulation of apical polarity factors at the apical cortex. The levels of aPKC and Par-6 are significantly increased in slmb mutants, whereas Baz is slightly reduced. Thus, Slmb may induce the polarisation of the anterior-posterior axis of the oocyte by targeting the Par-6/aPKC complex for degradation at the oocyte posterior. Consistent with this, overexpression of the aPKC antagonist Lgl strongly rescues the polarity defects of slmb mutant germline clones. The role of Slmb in oocyte polarity raises an intriguing parallel with C. elegans axis formation, in which PAR-2 excludes the anterior PAR complex from the posterior cortex to induce polarity, but its function can be substituted by overexpressing Lgl.