23 March 2022 in IEEE Transactions on Instrumentation and Measurement
This study proposes an automatic image water-level measurement system using a single camera. The inverse perspective mapping (IPM) technology is used to rectify an image to improve deviations because the optical axis of the camera and staff gauge are not orthogonal, causing a perspective distortion in the real environment. The initial position of the current watermark is first determined from the staff gauge’s image by applying basic digital image-processing technology. The system uses the image histogram of staff gauge’s region of interest to provide a reference region for determining accurate water levels from the preliminary watermark position. Furthermore, the proposed system can correctly and automatically determine the current water-level elevation by establishing the control points to convert the pixel distance to the real-world distance as well as through the setting of the reference water-level elevation. The images are shifted because of camera vibration, which will also shift the waterline coordinates. To prevent the image shift due to camera vibration from interfering with the accuracy of water-level measurement, we used the normalized cross-correlation technology with the proposed camera-vibration calibration scheme for removing the impact. The proposed distance calibration module further optimizes the results of the images rectified using the IPM technology. The suggested automatic water-level measurement system can improve the traditional linear interpolation approach by >90%, and the deviation value of the real water level is <0.5 cm, which is ideal for water-level measurement in confined spaces according to experimental results.
1 August 2021 in Review of Scientific Instruments
To prevent flooding from threatening people’s lives and property, surveillance cameras have been extensively installed along rivers to monitor the water level. In this study, an automatic water-level measurement system based on a single camera is proposed. The system uses the images captured by the camera to verify the water levels of the rivers. The preliminary positions of the current water marks are first identified from the images of the staff gauges installed on site using the basic digital image processing technology. To establish the correct water levels from the preliminary water mark positions, the system uses the image histogram of the staff gauge region of interest to provide a reference for the water-level determination mechanism. The camera position typically results in a nonorthogonal angle between the camera’s optical axis and the on-site staff gauge plane because it causes perspective distortion that eventually leads to deviations. When the water level is low, the distance of the water line deviation from the orthogonal position becomes larger, and the actual distance represented by the pixel also becomes larger, resulting in greater deviations. To address this issue, this system adopts the inverse perspective mapping method to rectify the perspective distortion. By setting the reference water level and control points, this system can accurately calculate water levels. Experimental results demonstrate that the proposed automatic water-level measurement system as applied in confined spaces can reduce the image measurement error caused by the perspective distortion as well as verify and identify the current water levels.
31 October 2022 in IEEE Transactions on Instrumentation and Measurement
In the above article, we find that formula (11) has an error. It was introduced during the manuscript editing process and did not affect the results. We are sorry for this error and have corrected it.