A rapid and high-throughput fluorescence detection method for zearalenone (ZEN) based on a CuO nanoparticle (NP)-assisted signal amplification immunosensor was developed using an automated sample pretreatment and signal conversion system. CuO NPs with high stability and biocompatibility were used as carriers to immobilize anti-ZEN antibodies. The obtained CuO NP-anti-ZEN can maintain the ability to recognize target toxins and act as both a signal source and carrier to achieve signal conversion using automated equipment. In this process, target toxin detection is indirectly transformed to Cu2+ detection because of the large number of Cu2+ ions released from CuO NPs under acidic conditions. Finally, a simple and high-throughput fluorescence assay based on a fluorescent tripeptide molecule was employed to detect Cu2+, using a multifunctional microporous plate detector. A good linear relationship was observed between the fluorescence signal and the logarithm of ZEN concentration in the range of 16.0–1600.0 μg/kg. Additionally, excellent accuracy with a high recovery yield of 99.2–104.9% was obtained, which was concordant with the results obtained from LC-MS/MS of naturally contaminated samples. The CuO NP-based assay is a powerful and efficient screening tool for ZEN detection and can easily be modified to detect other mycotoxins.
A simple, rapid, sensitive, accurate, and automatic graphite furnace atomic absorption spectrometry (GFAAS) method for detecting Cd and Pb in cereals is presented. This method enables the simultaneous determination of Cd and Pb in cereals with a pre-treatment method of diluted acid extraction and a high-performance lead–cadmium composite hollow-cathode lamp (LCC-HCL), and it realizes automatic determination from sample weighing to result output through an automatic diluted acid extraction system. Under the optimization, Pb and Cd in cereals were simultaneously and automatically detected in up to 240 measurements in 8 h. The LOD and LOQ of this method were 0.012 and 0.040 mg·kg−1 for Pb, and 0.0014 and 0.0047 mg·kg−1 for Cd, respectively. The results of the four certified reference materials were satisfied; there was no significant difference compared with the ICP-MS method according to a t-test, and the RSDs were less than 5% for Cd and Pb. The recoveries of naturally contaminated samples compared with the ICP-MS method were favorable, with 80–110% in eight laboratories. The developed method is rapid, low-cost, and highly automated and may be a good choice for grain quality discrimination and rapid analysis of Cd and Pb in different institutions.
In response to the demand for reference material under the EU Maximum Levels for Nickel (Ni) limit in soybeans (15 mg/kg) in 2024, this study explored the technical difficulty of ensuring the homogeneity of Ni reference material in the soybean matrix. Multi-scale characterization (LA-ICP-MS, ICP-MS, FT-IR, etc.) verified that Ni was specifically enriched in embryo and the finer powder (mainly embryo). Based on this finding, we innovatively proposed the span [(D90 − D10)/D50] as a rapid predictor to evaluate homogeneity, offering a potential screening tool to optimize grinding conditions and reduce reliance on time-consuming traditional homogeneity assessments (Ni-RSD by ICP-MS). A positive correlation between span and homogeneity was observed, which was attributed to the inhomogeneous distribution of low-Ni tissue (seed coat). By optimizing the crushing process (hammer cyclone milling, room temperature: 20 °C, 15,000 r/min, ≤ 0.45 mm sieve), a homogeneity uncertainty of 1.00% was obtained. This finding helps in ensuring the homogeneity of reference materials from other high-fat oilseed matrixes.