Zhihong Xuan

Ms. Zhihong Xuan

assistant professor

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in Foods
Verified
Journal Article
Open access
PDF file
WSWenjie Shen
Wenjie Shen
ZXZhihong Xuan
Zhihong Xuan
HLHongmei Liu
Hongmei Liu
KHKai Huang
Kai Huang
XGXiao Guan
Xiao Guan
BGBaoyuan Guo
Baoyuan Guo
Lactoferrin (LF), an iron-binding glycoprotein with immunological properties and a high nutritional value, has emerged as a prominent research focus in the field of food nutrition. Lactoferrin is widely distributed in raw milk and milk that has undergone low-temperature heat treatment during pasteurization, making its rapid and accurate detection crucial for ensuring the quality control of dairy products. An enzyme-linked immunosorbent assay-based analytical protocol has often been referred to for the detection of LF in real samples. Signal amplification was accomplished using the streptavidin–biotin system. Here, an automated magnetic beads-based sandwich chemiluminescence enzyme immunoassay (MBs-sCLEIA) system was developed for the quantification of lactoferrin in pasteurized milk. The MBs-sCLEIA system consists of an automated chemiluminescence-based analyzer and a lactoferrin MBs-sCLEIA assay kit. Notably, our proposed method eliminates the need for pretreatment procedures and enables the direct addition of milk samples, allowing for the automatic quantitative detection of lactoferrin within a rapid 17 min timeframe for up to eight samples simultaneously. The MBs-sCLEIA was linear over the range of 7.24–800 ng/mL and displayed a limit of detection (LOD) of 2.85 ng/mL. As its good recovery and CV values indicate, the method exhibited high precision and accuracy. Furthermore, it was verified that it was selective towards five additional common milk proteins. A good correlation was observed between the results from the MBs-sCLEIA and heparin affinity column-HPLC (r2 = 0.99042), which proves to be a useful and practicable way of conducting an accurate analysis of lactoferrin in dairy products.

15 May 2023 in Toxins
Verified
Journal Article
Open access
PDF file
BNBaoxia Ni
Baoxia Ni
JYJIN YE
JIN YE
ZXZhihong Xuan
Zhihong Xuan
LLLi Li
Li Li
XWXiangrui Wen
Xiangrui Wen
SWSongxue Wang
Songxue Wang
Sample pretreatment is a vital step in the detection of mycotoxins, and traditional pretreatment methods are time-consuming, labor-intensive and generate much organic waste liquid. In this work, an automatic, high-throughput and environmentally friendly pretreatment method is proposed. Immunomagnetic beads technology and dispersive liquid–liquid microextraction technology are combined, and the zearalenone in corn oils is directly purified and concentrated under the solubilization effects of surfactant. The proposed pretreatment method allows for the batch pretreatment of samples without pre-extraction using organic reagents, and almost no organic waste liquid is produced. Coupled with UPLC-FLD, an effective and accurate quantitative detection method for zearalenone is established. The recovery of spiked zearalenone in corn oils at different concentrations ranges from 85.7 to 89.0%, and the relative standard deviation is below 2.9%. The proposed pretreatment method overcomes the shortcomings of traditional pretreatment methods and has broad application prospects.

25 January 2022 in Toxins
Verified
Journal Article
Open access
PDF file
HLHongmei Liu
Hongmei Liu
ZXZhihong Xuan
Zhihong Xuan
JYJIN YE
JIN YE
JCJinnan Chen
Jinnan Chen
MWMeng Wang
Meng Wang
SWSongxue Wang
Songxue Wang
An immunoaffinity magnetic beads (IMBs) based automatic pretreatment method was developed for the quantitative analysis of deoxynivalenol (DON) by ultra-performance liquid chromatography and ultraviolet detector (UPLC-UV). First, N-hydroxysuccinimide-terminated magnetic beads (NHS-MBs) with good magnetic responsivity and dispersibility were synthesized and characterized by optical microscopy, scanning electron microscopy (SEM), and laser diffraction-based particle size analyzer. Then, the amino groups of anti-DON monoclonal antibody (mAb) and the NHS groups of NHS-MBs were linked by covalent bonds to prepare IMB, without any activation reagent. The essential factors affecting the binding and elution of DON were meticulously tuned. Under optimal conditions, DON could be extracted from a real sample and eluted from IMB by water, enabling environmentally friendly and green analysis. Hence, there was no need for dilution or evaporation prior to UPLC-UV analysis. DON in 20 samples could be purified and concentrated within 30 min by the mycotoxin automated purification instrument (MAPI), allowing for automated, green, high-throughput and simple clean-up. Recoveries at four distinct spiking levels in corn and wheat ranged from 92.0% to 109.5% with good relative standard deviations (RSD, 2.1–7.0%). Comparing the test results of IAC and IMB in commercial samples demonstrated the reliability and superiority of IMB for quantitatively analyzing massive samples.

30 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ZXZhihong Xuan
Zhihong Xuan
YWYanxiang Wu
Yanxiang Wu
HLHongmei Liu
Hongmei Liu
LLLi Li
Li Li
JYJIN YE
JIN YE
SWSongxue Wang
Songxue Wang
A rapid and high-throughput fluorescence detection method for zearalenone (ZEN) based on a CuO nanoparticle (NP)-assisted signal amplification immunosensor was developed using an automated sample pretreatment and signal conversion system. CuO NPs with high stability and biocompatibility were used as carriers to immobilize anti-ZEN antibodies. The obtained CuO NP-anti-ZEN can maintain the ability to recognize target toxins and act as both a signal source and carrier to achieve signal conversion using automated equipment. In this process, target toxin detection is indirectly transformed to Cu2+ detection because of the large number of Cu2+ ions released from CuO NPs under acidic conditions. Finally, a simple and high-throughput fluorescence assay based on a fluorescent tripeptide molecule was employed to detect Cu2+, using a multifunctional microporous plate detector. A good linear relationship was observed between the fluorescence signal and the logarithm of ZEN concentration in the range of 16.0–1600.0 μg/kg. Additionally, excellent accuracy with a high recovery yield of 99.2–104.9% was obtained, which was concordant with the results obtained from LC-MS/MS of naturally contaminated samples. The CuO NP-based assay is a powerful and efficient screening tool for ZEN detection and can easily be modified to detect other mycotoxins.

1 July 2022 in Toxins
Verified
Journal Article
Open access
PDF file
JYJIN YE
JIN YE
MZMengyao Zheng
Mengyao Zheng
HMHai hua Ma
Hai hua Ma
ZXZhihong Xuan
Zhihong Xuan
WTWei Tian
Wei Tian
YZYuan Zhang
Yuan Zhang
A chromatography-free detection of aflatoxin B1 (AFB1) in cereals and oils through atomic absorption spectroscopy (AAS) has been developed using quantum dots and immunomagnetic beads. A magneto-controlled pretreatment platform for automatic purification, labeling, and digestion was constructed, and AFB1 detection through AAS was enabled. Under optimal conditions, this immunoassay exhibited high sensitivity for AFB1 detection, with limits of detection as low as 0.04 μg/kg and a linear dynamic range of 2.5–240 μg/kg. The recoveries for four different food matrices ranged from 92.6% to 108.7%, with intra- and inter-day standard deviations of 0.7–6.3% and 0.6–6.9%, respectively. The method was successfully applied to the detection of AFB1 in husked rice, maize, and polished rice samples, and the detection results were not significantly different from those of liquid chromatography-tandem mass spectrometry. The proposed method realized the detection of mycotoxins through AAS for the first time. It provides a new route for AFB1 detection, expands the application scope of AAS, and provides a reference for the simultaneous determination of multiple poisonous compounds (such as mycotoxins and heavy metals).