Ronald N. Fortunato

Ronald N. Fortunato

Auto-generated profile, based on publicly available information

Ronald N. Fortunato

Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15261, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
JTJames R. Thunes
James R. Thunes
SPSiladitya Pal
Siladitya Pal
RFRonald N. Fortunato
Ronald N. Fortunato
JPJulie A. Phillippi
Julie A. Phillippi
TGThomas G. Gleason
Thomas G. Gleason
SMSpandan Maiti
Spandan Maiti

4 April 2018 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
CSChao Sang
Chao Sang
SMSpandan Maiti
Spandan Maiti
RFRonald N. Fortunato
Ronald N. Fortunato
JKJulia Kofler
Julia Kofler
ARAnne M. Robertson
Anne M. Robertson
Although uniaxial tensile testing is commonly used to evaluate failure properties of vascular tissue, there is no established protocol for specimen shape or gripping method. Large percentages of specimens are reported to fail near the clamp and can potentially confound the studies, or, if discarded will result in sample waste. The objective of this study is to identify sample geometry and clamping conditions that can achieve consistent failure in the midregion of small arterial specimens, even for vessels from older individuals. Failure location was assessed in 17 dogbone specimens from human cerebral and sheep carotid arteries using soft inserts. For comparison with commonly used protocols, an additional 22 rectangular samples were tested using either sandpaper or foam tape inserts. Midsample failure was achieved in 94% of the dogbone specimens, while only 14% of the rectangular samples failed in the midregion, the other 86% failing close to the clamps. Additionally, we found midregion failure was more likely to be abrupt, caused by cracking or necking. In contrast, clamp failure was more likely to be gradual and included a delamination mode not seen in midregion failure. Hence, this work provides an approach that can be used to obtain consistent midspecimen failure, avoiding confounding clamp-related artifacts. Furthermore, with consistent midregion failure, studies can be designed to image the failure process in small vascular samples providing valuable quantitative information about changes to collagen and elastin structure during the failure process.

4 June 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
RFRonald N. Fortunato
Ronald N. Fortunato
ARAnne M. Robertson
Anne M. Robertson
CSChao Sang
Chao Sang
SMSpandan Maiti
Spandan Maiti

21 May 2018 in Soft Matter
Verified
Journal Article
Closed access
PDF file
RRRahul G. Ramachandran
Rahul G. Ramachandran
SHS. Hariharakrishnan
S. Hariharakrishnan
RFRonald Fortunato
Ronald Fortunato
SASteven D. Abramowitch
Steven D. Abramowitch
SMSpandan Maiti
Spandan Maiti
SVSachin S. Velankar
Sachin S. Velankar
Effect of bonding a rubber layer to a plastic layer that undergoes necking in tension.