Zhiyuan Jiang

Zhiyuan Jiang

Auto-generated profile, based on publicly available information

Zhiyuan Jiang

National Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University , Xi’an 710049

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2024 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
WWWei Wang
Wei Wang
JWJian Wu
Jian Wu
ZJZhiyuan Jiang
Zhiyuan Jiang
YLYuanbo Lu
Yuanbo Lu
ZWZhenyu Wang
Zhenyu Wang
AQAici Qiu
Aici Qiu
Measurement of plasma parameters during the ablation phase in the Z-pinch is crucial for investigating the dynamic behaviors. In this study, optical Thomson scattering was employed to measure the temperature and velocity of the ablation plasma in a double-wire Z-pinch. The scattering spectra profiles were fitted using a model that considered the velocity distribution. The experimental results revealed the energy evolution of ablation plasma, the establishment of the global magnetic field and the development of axial non-uniformities. The precursor plasma was found to play a key role in strengthening the global magnetic field. A resistive layer near the wire core with a size of 1.5 mm was observed in the ablation plasma after the precursor plasma column formed. The plasma underwent rapid heating in this layer, the electron temperature rises from 17 eV to 22 eV. Upon leaving this layer, electron the temperature is stable at around 22 eV. The radial distribution of the ablation rate increases and decreases, indicating the axial motion of the ablation plasma, which could be caused by the tilt motion of the stream and the secondary modulation of the natural wavelength.

20 June 2023 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
ZJZhiyuan Jiang
Zhiyuan Jiang
JWJian Wu
Jian Wu
ZWZhenyu Wang
Zhenyu Wang
ZCZiwei Chen
Ziwei Chen
WWWei Wang
Wei Wang
DZDaoyuan Zhang
Daoyuan Zhang
This paper investigates the two-dimensional magnetic field structure of a double-wire Z-pinch during the ablation stage using Faraday rotation diagnosis. The experimental results intuitively display the two-dimensional magnetic field distribution and reveal the process of the global magnetic field spreading towards the load axis as the ablation progresses. The radial current component is determined based on the axial non-uniformity of the magnetic field structure, which further confirms the two-dimensional current path within the ablation stream. Additionally, the significantly enhanced magnetic field intensity and opposing magnetic field direction on both sides of the precursor plasma column indicate the existence of magnetic reconnection and the current layer within the precursor. This process also explicitly reveals the current transfer process from the wire to the precursor column. Through this structured investigation, we facilitate experimental validation of existing simulation outcomes and offer a more intuitive demonstration.

1 January 2025 in Physics of Plasmas
Verified
Journal Article
Open access
PZPeizhou Zhang
Peizhou Zhang
HSHuantong Shi
Huantong Shi
DWDongsheng Wang
Dongsheng Wang
MXMing Xu
Ming Xu
TWTongquan Wang
Tongquan Wang
XLXingwen Li
Xingwen Li
The rod-pinch diode (RPD) is one of the most iconic load configurations for flash x-ray radiography, which offers advantages of simple structure and high-quality x-ray spot. While physical models have been well-developed for the classic vacuum RPD since the 1970s, research remains lacking for its low-impedance variant using a metal wire to pre-short the anode–cathode gap, particularly on the plasma dynamics following electrical wire explosion (EWE) in the diode. The wire-shorted RPD features an operating impedance of <1 Ω, which is desirable on a high-current low-impedance pulse driver for high x-ray dose conversion. This work investigates the joint phenomenology from the plasma diagnostics, electrical measurements, and radiation detections of a wire-shorted RPD, offering a novel perspective on its plasma behaviors. Results from both experiment and magneto-hydrodynamic simulation show that the wire trailing mass persists throughout the x-ray emission phase, with only fractional mass adjacent to the anode pushed toward the rod tip. Unlike the micro diode at rod tip in a plasma-prefilled RPD, the much denser EWE plasma in a wire-shorted RPD forms an extended current return path prior to x-ray burst, and the electrons pinched at the rod tip are emitted from a large cathode area.

24 August 2023 in Nuclear Fusion
Verified
Journal Article
Open access
PDF file
ZJZhiyuan Jiang
Zhiyuan Jiang
JWJian Wu
Jian Wu
WWWei Wang
Wei Wang
ZCZiwei Chen
Ziwei Chen
XZXinmiao Zhou
Xinmiao Zhou
XLXingwen Li
Xingwen Li
In this study, the effect and mechanism of a dynamic axial magnetic field on a preconditioned single-wire Z-pinch were investigated experimentally and theoretically. Optical diagnostic methods, including shadowgraphy, interferometry, Faraday rotation, and Thomson scattering, have been used to measure the parameters of magnetized plasmas. Compression of the azimuthal and axial magnetic fields was observed, and the suppression of the plasma instability was recorded and analyzed. The results showed that an external axial magnetic field could reduce the plasma instability and non-uniformity, but prolong the implosion time and weaken the compression ratio. In the implosion process with an axial magnetic field, the plasma rotated at a speed similar to that of imploding, which could be regarded as a stabilization method. A simplified model of the diffusion and compression processes of a dynamic axial magnetic field was developed to investigate the conditions for maximizing the amplitude of the axial magnetic field. Subsequently, the snowplow model was used to calculate the effect of axial magnetic fields on the implosion process and energy conversion.

1 September 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
YZYiming Zhao
Yiming Zhao
JWJian Wu
Jian Wu
ZJZhiyuan Jiang
Zhiyuan Jiang
WWWei Wang
Wei Wang
ZWZhenyu Wang
Zhenyu Wang
AQAici Qiu
Aici Qiu
Measuring the electron density of low-density plasma has long been a challenge, as traditional diagnostic techniques often lack sufficient sensitivity or spatial resolution. To address this, this paper presents an electron density diagnostic method for corona plasma generated by electrical wire explosion, based on a Shack–Hartmann wavefront sensor. The diagnostic system integrates an 8 ns, 532 nm nanosecond pulsed laser, a 400 mm focal length lens array, and a high-resolution charge-coupled device camera. By integrating the proposed neural network methods with micro-lens optical simulations, we achieved sub-pixel-level centroid localization of the focal spot, reducing shift errors by 21% compared to conventional convolutional neural network methods and achieving sub-pixel accuracy with an error of only 0.25 pixels. The theoretical sensitivity of the system reaches 2 × 1015 cm−2. In experiments using a silver-wire load under pre-pulse conditions, this diagnostic technique demonstrated strong agreement with laser interferometry results in high density regions. In low-density regions, the electron density measured at 4.4 mm from the wire axis reached a minimum of 2.2 × 1016 cm−2, offering a broader spatial range for plasma electron density diagnostics compared to laser interferometry. This method effectively captured the electron density distribution of the corona plasma formed under pre-pulse conditions. Future work will focus on further optimizing the experimental system to reduce sources of error and extending the application of this technique to large-scale pulsed power facilities for diagnosing the formation and parameter distribution of low-density electrode plasmas.

1 December 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
ZJZhiyuan Jiang
Zhiyuan Jiang
JWJian Wu
Jian Wu
WWWei Wang
Wei Wang
ZCZiwei Chen
Ziwei Chen
ZWZhenyu Wang
Zhenyu Wang
HSHuantong Shi
Huantong Shi
The radiation properties including size, intensity, and pulse width of the double-wire X-pinch were optimized using prepulse current. The optimization mechanism was investigated using optical diagnostics. The X-pinch driven by a current with a peak intensity of ∼250 kA and a rise rate of 0.95 kA/ns was difficult to produce strong radiation. The application of prepulse effectively enhances the current rise rate and intensity of the radiation source. The radiation source also exhibited reduced spatial dimensions and radiation duration, thereby improving spatial and temporal resolution while used in x-ray projection shadow radiography. The magnetic field and current distribution were measured using Faraday rotation. During the early stage, the current predominantly flows in the corona plasma at a larger radius generated by the prepulse current, consequently reducing the load inductance. As the time delay between the main and prepulse current increased, the intensity of the radiation source further increased. This study provides an approach for controlling radiation sources and enables different applications of X-pinches with adjustable prepulse current.