Yongyu Xie

Yongyu Xie

Auto-generated profile, based on publicly available information

Yongyu Xie

Georgia Institute of Technology

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2023 in IEEE Security & Privacy
Verified
Journal Article
Closed access
CDConstantine Doumanidis
Constantine Doumanidis
YXYongyu Xie
Yongyu Xie
PRPrashant H.N. Rajput
Prashant H.N. Rajput
RPRyan Pickren
Ryan Pickren
BSBurak Sahin
Burak Sahin
MMMichail Maniatakos
Michail Maniatakos
Industrial control system (ICS) platforms are increasingly relying on third-party software components forming an untrusted supply chain. In this work, we investigate components and their security in this supply chain, dissecting firmware from major international ICS vendors.

28 February 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
MTMuhammad Nabeel Tahir
Muhammad Nabeel Tahir
YXYongyu Xie
Yongyu Xie
MSMuhammad Ahsan Sami
Muhammad Ahsan Sami
RPRasika Punde
Rasika Punde
UHUmer Hassan
Umer Hassan
Fluorescence microscopes are widely used to detect fluore-scent objects in a biological sample. However, traditional benchtop fluorescence microscopes are limited to high cost and nonportability. Recently, smartphone-based fluorescence microscopes (SFMs) have been developed, which capture images using a smartphone camera with the help of an external optical device and serve as an inexpensive and portable alternative. However, to analyze the images and get the accurate count of bioparticles, external software and computational resources are required; moreover, the lack of single and clustered count capabilities in SFMs without relying on an image library limits the use of SFMs. Here, we present an automated method as a mobile application with the ability to provide the bioparticle counts at the point of care by imaging human leukocytes and fluorescent microparticles. The application employs efficient image processing techniques that result in faster automated counting and reduced computational cost while providing comparable counts to industrial and academic standards. Compared with counting results calculated by ImageJ, a correlation coefficient of ${{R}^2}$ > 0.99 was observed along with the average relative error of ∼0.5% on different kinds of fluorescent images.

24 July 2026
Verified
Book Chapter
Closed access
PDF file
YXYongyu Xie
Yongyu Xie
DKDaniel Khoshkhoo
Daniel Khoshkhoo
HLHithem Lamri
Hithem Lamri
CDConstantine Doumanidis
Constantine Doumanidis
BDBrian Davidson
Brian Davidson
SZSaman Zonouz
Saman Zonouz