David Pierson Bradway

David Pierson Bradway

Auto-generated profile, based on publicly available information

David Pierson Bradway

Duke University

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BFB J Fahey
B J Fahey
RNR C Nelson
R C Nelson
DBD P Bradway
D P Bradway
SHS J Hsu
S J Hsu
DDD M Dumont
D M Dumont
GTG E Trahey
G E Trahey
The utility of acoustic radiation force impulse (ARFI) imaging for real-time visualization of abdominal malignancies was investigated. Nine patients presenting with suspicious masses in the liver (n= 7) or kidney (n= 2) underwent combined sonography/ARFI imaging. Images were acquired of a total of 12 tumors in the nine patients. In all cases, boundary definition in ARFI images was improved or equivalent to boundary definition in B-mode images. Displacement contrast in ARFI images was superior to echo contrast in B-mode images for each tumor. The mean contrast for suspected hepatocellular carcinomas (HCCs) in B-mode images was 2.9 dB (range: 1.5–4.2) versus 7.5 dB (range: 3.1–11.9) in ARFI images, with all HCCs appearing more compliant than regional cirrhotic liver parenchyma. The mean contrast for metastases in B-mode images was 3.1 dB (range: 1.2–5.2) versus 9.3 dB (range: 5.7–13.9) in ARFI images, with all masses appearing less compliant than regional non-cirrhotic liver parenchyma. ARFI image contrast (10.4 dB) was superior to B-mode contrast (0.9 dB) for a renal mass. To our knowledge, we present the firstin vivoimages of abdominal malignancies in humans acquired with the ARFI method or any other technique of imaging tissue elasticity.

3 February 2016 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
NBNick Bottenus
Nick Bottenus
WLWill Long
Will Long
HZHaichong Zhang
Haichong Zhang
MJMarko Jakovljevic
Marko Jakovljevic
DBDavid P. Bradway
David P. Bradway
GTGregg E. Trahey
Gregg E. Trahey
Ultrasound image quality is often inherently limited by the physical dimensions of the imaging transducer. We hypothesize that, by collecting synthetic aperture data sets over a range of aperture positions while precisely tracking the position and orientation of the transducer, we can synthesize large effective apertures to produce images with improved resolution and target detectability. We analyze the two largest limiting factors for coherent signal summation: aberration and mechanical uncertainty. Using an excised canine abdominal wall as a model phase screen, we experimentally observed an effective arrival time error ranging from 18.3 ns to 58 ns (root-mean-square error) across the swept positions. Through this clutter-generating tissue, we observed a 72.9% improvement in resolution with only a 3.75 dB increase in side lobe amplitude compared to the control case. We present a simulation model to study the effect of calibration and mechanical jitter errors on the synthesized point spread function. The relative effects of these errors in each imaging dimension are explored, showing the importance of orientation relative to the point spread function. We present a prototype device for performing swept synthetic aperture imaging using a conventional 1-D array transducer and ultrasound research scanner. Point target reconstruction error for a 44.2 degree sweep shows a reconstruction precision of 82.8 $\mu {\rm m}$ and 17.8 $\mu {\rm m}$ in the lateral and axial dimensions respectively, within the acceptable performance bounds of the simulation model. Improvements in resolution, contrast and contrast-to-noise ratio are demonstrated in vivo and in a fetal phantom.

1 October 2008 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
BFBrian J. Fahey
Brian J. Fahey
RNRendon C. Nelson
Rendon C. Nelson
SHStephen J. Hsu
Stephen J. Hsu
DBDavid P. Bradway
David P. Bradway
DDDouglas M. Dumont
Douglas M. Dumont
GTGregg E. Trahey
Gregg E. Trahey

1 November 2012 in Heart Rhythm
Verified
Journal Article
Closed access
SEStephanie A. Eyerly
Stephanie A. Eyerly
TBTristram D. Bahnson
Tristram D. Bahnson
JKJason I. Koontz
Jason I. Koontz
DBDavid P. Bradway
David P. Bradway
DDDouglas M. Dumont
Douglas M. Dumont
PWPatrick D. Wolf
Patrick D. Wolf

23 November 2015 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
MPMichael Johannes Pihl
Michael Johannes Pihl
SHSimon Holbek
Simon Holbek
CHCarlos Armando Villagomez Hoyos
Carlos Armando Villagomez Hoyos
BTBorislav Gueorguiev Tomov
Borislav Gueorguiev Tomov
A method for rapid measurement of intensities (Ispta), mechanical index (MI), and probe surface temperature for any ultrasound scanning sequence is presented. It uses the scanner's sampling capability to give an accurate measurement of the whole imaging sequence for all emissions to yield the true distributions. The method is several orders of magnitude faster than approaches using an oscilloscope, and it also facilitates validating the emitted pressure field and the scanner's emission sequence software. It has been implemented using the experimental synthetic aperture real-time ultrasound system (SARUS) scanner and the Onda AIMS III intensity measurement system (Onda Corporation, Sunnyvale, CA, USA). Four different sequences have been measured: a fixed focus emission, a duplex sequence containing B-mode and flow emissions, a vector flow sequence with B-mode and flow emissions in 17 directions, and finally a SA duplex flow sequence. A BK8820e (BK Medical, Herlev, Denmark) convex array probe is used for the first three sequences and a BK8670 linear array probe for the SA sequence. The method is shown to give the same intensity values within 0.24% of the AIMS III Soniq 5.0 (Onda Corporation, Sunnyvale, CA, USA) commercial intensity measurement program. The approach can measure and store data for a full imaging sequence in 3.8-8.2 s per spatial position. Based on Ispta, MI, and probe surface temperature, the method gives the ability to determine whether a sequence is within U.S. FDA limits, or alternatively indicate how to scale it to be within limits.

2 August 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PHPeter Hollender
Peter Hollender
DBDavid Bradway
David Bradway
PWPatrick Wolf
Patrick Wolf
RGRobi Goswami
Robi Goswami
GTGregg Trahey
Gregg Trahey
Four pigs, three with focal infarctions in the apical intraventricular septum (IVS) and/or left ventricular free wall (LVFW), were imaged with an intracardiac echocardiography (ICE) transducer. Custom beam sequences were used to excite the myocardium with focused acoustic radiation force (ARF) impulses and image the subsequent tissue response. Tissue displacement in response to the ARF excitation was calculated with a phase-based estimator, and transverse wave magnitude and velocity were each estimated at every depth. The excitation sequence was repeated rapidly, either in the same location to generate 40 Hz M-modes at a single steering angle, or with a modulated steering angle to synthesize 2-D displacement magnitude and shear wave velocity images at 17 points in the cardiac cycle. Both types of images were acquired from various views in the right and left ventricles, in and out of infarcted regions. In all animals, acoustic radiation force impulse (ARFI) and shear wave elasticity imaging (SWEI) estimates indicated diastolic relaxation and systolic contraction in noninfarcted tissues. The M-mode sequences showed high beat-to-beat spatio-temporal repeatability of the measurements for each imaging plane. In views of noninfarcted tissue in the diseased animals, no significant elastic remodeling was indicated when compared with the control. Where available, views of infarcted tissue were compared with similar views from the control animal. In views of the LVFW, the infarcted tissue presented as stiff and non-contractile compared with the control. In a view of the IVS, no significant difference was seen between infarcted and healthy tissue, whereas in another view, a heterogeneous infarction was seen to be presenting itself as non-contractile in systole.