3 August 2022 in IEEE Transactions on Biomedical Engineering
Objective: The bidomain model and the finite element method are an established standard to mathematically describe cardiac electrophysiology, but are both suboptimal choices for fast and large-scale simulations due to high computational costs. We investigate to what extent simplified approaches for propagation models (monodomain, reaction-Eikonal and Eikonal) and forward calculation (boundary element and infinite volume conductor) deliver markedly accelerated, yet physiologically accurate simulation results in atrial electrophysiology. Methods: We compared action potential durations, local activation times (LATs), and electrocardiograms (ECGs) for sinus rhythm simulations on healthy and fibrotically infiltrated atrial models. Results: All simplified model solutions yielded LATs and P waves in accurate accordance with the bidomain results. Only for the Eikonal model with pre-computed action potential templates shifted in time to derive transmembrane voltages, repolarization behavior notably deviated from the bidomain results. ECGs calculated with the boundary element method were characterized by correlation coefficients $>$ 0.9 compared to the finite element method. The infinite volume conductor method led to lower correlation coefficients caused predominantly by systematic overestimations of P wave amplitudes in the precordial leads. Conclusion: Our results demonstrate that the Eikonal model yields accurate LATs and combined with the boundary element method precise ECGs compared to markedly more expensive full bidomain simulations. However, for an accurate representation of atrial repolarization dynamics, diffusion terms must be accounted for in simplified models. Significance: Simulations of atrial LATs and ECGs can be notably accelerated to clinically feasible time frames at high accuracy by resorting to the Eikonal and boundary element methods.
7 January 2025 in Engineering with Computers
Computer models for simulating cardiac electrophysiology are valuable tools for research and clinical applications. Traditional reaction–diffusion (RD) models used for these purposes are computationally expensive. While eikonal models offer a faster alternative, they are not well-suited to study cardiac arrhythmias driven by reentrant activity. The present work extends the diffusion–reaction eikonal alternant model (DREAM), incorporating conduction velocity (CV) restitution for simulating complex cardiac arrhythmias. The DREAM modifies the fast iterative method to model cyclical behavior, dynamic boundary conditions, and frequency-dependent anisotropic CV. Additionally, the model alternates with an approximated RD model, using a detailed ionic model for the reaction term and a triple-Gaussian to approximate the diffusion term. The DREAM and monodomain models were compared, simulating reentries in 2D manifolds with different resolutions. The DREAM produced similar results across all resolutions, while experiments with the monodomain model failed at lower resolutions. CV restitution curves obtained using the DREAM closely approximated those produced by the monodomain simulations. Reentry in 2D sheets yielded similar results in vulnerable window and mean reentry duration for low CV in both models. In the left atrium, most inducing points identified by the DREAM were also present in the high-resolution monodomain model. DREAM’s reentry simulations on meshes with an average edge length of $$1600\,\upmu \hbox {m}$$ were 87x faster than monodomain simulations at $$200\,\upmu \hbox {m}$$ . This work establishes the mathematical foundation for using the accelerated DREAM simulation method for cardiac electrophysiology. Cardiac research applications are enabled by a publicly available implementation in the openCARP simulator.
23 March 2025 in Computers in Biology and Medicine
Premature ventricular contractions (PVCs) represent a common and clinically significant cardiac arrhythmia, contributing to a spectrum of cardiovascular disorders. Accurate localization of the origin of PVCs is essential for devising targeted therapeutic strategies and refining our comprehension of ventricular arrhythmogenesis. Traditionally, the 12-lead ECG has been the go-to diagnostic tool for PVCs. However, individual anatomical differences and inter-patient electrophysiology variability limit its effectiveness. This study presents a new method that combines electrocardiographic imaging (ECGI) with the concept of cardiac digital twins (ECGI-DT) to improve the accuracy of pinpointing the source of PVCs. By simulating a database of PVCs, we developed an ECGI-DT capable of estimating the origins of PVCs with much greater precision than possible previously. This study shows a notable improvement in identifying the initial site of PVC origin using ECGI-DT compared to ECGI alone: the average localization error dropped from 30.69 ± 23.71 mm with standard ECGI to 7.81 ± 3.82 mm using the ECGI-DT method. This marked reduction in error highlights the potential of ECGI-DT in revolutionizing PVC diagnosis and treatment. With its ability to provide more accurate and reliable data, ECGI-DT could improve the planning of catheter ablation treatments, a preferred intervention for managing PVCs that face challenges such as high costs and in some cases long procedure times.
6 October 2026 in The Journal of Physiology
Left bundle branch block (LBBB) describes a disruption or delay in electrical conduction through the left bundle branch of the His‐Purkinje system (HPS). While new‐onset LBBB commonly emerges in individuals with a history of hypertension, cardiomegaly or coronary artery disease, it can also occur in the absence of other cardiovascular abnormalities. Whether LBBB is a cause or a consequence of heart failure remains unclear. In this work, we used six different electromechanical in silico heart models with an integrated HPS to simulate both a healthy control and a pure LBBB case for each geometry, affecting only the HPS in the absence of other cardiovascular pathologies. We compared electrophysiological, mechanical and haemodynamic metrics between both cases. Despite exhibiting a severe delay of up to 87 ms in left ventricular activation, all six virtual patients showed almost no acute change in ejection fraction (EF) due to LBBB. However, an absolute increase in septal flash of 1.4 mm to 2.7 mm indicated mechanical dyssynchrony. Furthermore, we observed a relative strain increase of 12.3–30% in the left ventricular free wall across all models. The load imbalance marked by the strain increase could drive LBBB‐induced remodelling, leading to a major reduction in EF over time. Regardless of variations in heart geometry, this study shows that electrical dyssynchrony immediately affects mechanics more than haemodynamics. In line with clinical data, our findings suggest that patients with LBBB might benefit from an earlier application of cardiac resynchronization therapy to prevent strain‐induced remodelling and preserve cardiac output. image Key points: Left bundle branch block (LBBB) describes an impairment of electrical conduction in the left bundle branch of the His‐Purkinje system, causing a delay in left ventricular activation. While LBBB has been discussed as a risk factor for the progression of heart failure, the exact relationship of acute and chronic effects of LBBB in heart failure is not fully understood. In this study, we simulated both a healthy and a pure and acute LBBB scenario in six different electromechanical in silico heart models. Pure LBBB induced mechanical dyssynchrony, increasing septal flash and left ventricular free wall strain, while the ejection fraction remained virtually unchanged. The strain‐induced load imbalance may cause long‐term remodelling, reducing ejection fraction over time. In line with clinical data, our results suggest an early application of cardiac resynchronization therapy in patients with LBBB to prevent remodelling and sustain cardiac output.