Ryohei Yamauchi

Ryohei Yamauchi

Auto-generated profile, based on publicly available information

Ryohei Yamauchi

Department of Radiation Oncology, St. Luke's International Hospital, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2020 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
RYRyohei Yamauchi
Ryohei Yamauchi
NMNorifumi Mizuno
Norifumi Mizuno
TITomoko Itazawa
Tomoko Itazawa
HSHidetoshi Saitoh
Hidetoshi Saitoh
JKJiro Kawamori
Jiro Kawamori
Deep inspiration breath hold (DIBH) is a common method used worldwide for reducing the radiation dose to the heart. However, few studies have reported on the relationship between dose reduction and patient-specific parameters. The aim of this study was to compare the reductions of heart dose and volume using DIBH with the dose/volume of free breathing (FB) for patients with left-sided breast cancer and to analyse patient-specific dose reduction parameters. A total of 85 Asian patients who underwent whole-breast radiotherapy after breast-conserving surgery were recruited. Treatment plans for FB and DIBH were retrospectively generated by using an automated breast planning tool with a two-field tangential intensity-modulated radiation therapy technique. The prescribed dose was 50 Gy in 25 fractions. The dosimetric parameters (e.g., mean dose and maximum dose) in heart and lung were extracted from the dose–volume histogram. The relationships between dose–volume data and patient-specific parameters, such as age, body mass index (BMI), and inspiratory volume, were analyzed. The mean heart doses for the FB and DIBH plans were 1.56 Gy and 0.75 Gy, respectively, a relative reduction of 47%. There were significant differences in all heart dosimetric parameters (p < 0.001). For patients with a high heart dose in the FB plan, a relative reduction of the mean heart dose correlated with inspiratory volume (r = 0.646). There was correlation between the relative reduction of mean heart dose and BMI (r = −0.248). We recommend considering the possible feasibility of DIBH in low BMI patients because the degree of benefit from DIBH varied with BMI.

1 December 2021 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
NMNorifumi Mizuno
Norifumi Mizuno
TITomoko Itazawa
Tomoko Itazawa
TMTomoyuki Masuda
Tomoyuki Masuda
SAShinobu Akiyama
Shinobu Akiyama
JKJiro Kawamori
Jiro Kawamori

6 December 2023 in Medical Dosimetry
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
TITomoko Itazawa
Tomoko Itazawa
TKTakako Kobayashi
Takako Kobayashi
SKShiho Kashiyama
Shiho Kashiyama
HAHiroyoshi Akimoto
Hiroyoshi Akimoto
JKJiro Kawamori
Jiro Kawamori

1 December 2020 in Physica Medica
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
NMNorifumi Mizuno
Norifumi Mizuno
TITomoko Itazawa
Tomoko Itazawa
JKJiro Kawamori
Jiro Kawamori

26 April 2024 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
RIRyoko Ito
Ryoko Ito
TITomoko Itazawa
Tomoko Itazawa
FTFumihiro Tomita
Fumihiro Tomita
JKJiro Kawamori
Jiro Kawamori

10 March 2025 in Journal of Radiation Research
Verified
Journal Article
Open access
RYRyohei Yamauchi
Ryohei Yamauchi
FTFumihiro Tomita
Fumihiro Tomita
SISatoshi Ishikura
Satoshi Ishikura
Accelerated partial breast irradiation (APBI) is an alternative treatment for early-stage breast cancer. This study aimed to evaluate the effectiveness of the virtual bolus (VB) method and robust planning against respiratory motion in volumetric modulated arc therapy (VMAT)-APBI. VMAT plans were generated with 30 Gy in 5 fractions for 16 patients. Four treatment plans were developed and compared: a standard optimization (SO) plan without robust methods, a pseudo-skin flash strategy using a 5 mm VB (with densities of 0.4 and 1.0 g/cm3, VB04 and VB10), and a robust optimization (RO) plan to minimize penalties in worst-case scenarios. The isocenter was shifted 1–5 mm in each translational direction in robust analysis, and perturbed dose calculations were performed. All dose constraints for the target in SO and VB plans were within acceptable limits, but the dose evaluation volume V95% in the RO plan was lower than in other plans (P < 0.05). The clinical target volume V95% of the RO plan was significantly higher than in VB04 and VB10 (P < 0.05). The RO plan showed the best performance for organs at risk, followed by SO and VB plans, which resulted in higher doses. The RO plan exhibited the smallest change (±2%) in dose distribution due to respiratory motion. By contrast, the SO plan lacked robustness owing to absence of sufficient fluence in the air surrounding the planning target volume outside of the skin surface. The RO plan offers superior target coverage, maximum dose, and robustness compared to SO and VB methods.