Norifumi Mizuno

Norifumi Mizuno

Auto-generated profile, based on publicly available information

Norifumi Mizuno

Department of Radiation Oncology, St. Luke's International Hospital, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
NMNorifumi Mizuno
Norifumi Mizuno
HTHaruna Takahashi
Haruna Takahashi
JKJiro Kawamori
Jiro Kawamori
NNNaoki Nakamura
Naoki Nakamura
MOMami Ogita
Mami Ogita
KSKenji Sekiguchi
Kenji Sekiguchi
Some patients undergoing breast reconstruction require post-mastectomy radiation therapy, but the metallic ports used in temporary tissue expanders attenuate the X-rays. In this study, we evaluated by the film method, the attenuation of 4 MV and 6 MV X-rays after passing through a metallic port, with the aim of identifying a useful method for determining the appropriate density to use in the radiation treatment planning system (RTPS), taking into account the distance between the metallic port and the targets. Radiochromic film was used to measure depth doses after the X-rays passed through the metallic port. The physical density allotted to the metal port portion was varied on the RTPS within the range 1–16 g/cm3, and the physical density values were calculated that best reproduced the depth–dose distribution extrapolated from the film method. When the metallic port was orientated perpendicularly, the attenuation of the X-rays peaked at ~7% at both 4 MV and 6 MV. In the parallel orientation, the X-rays were attenuated by up to ~40% at 4 MV and by up to ~30% at 6 MV. We estimated the optimum physical density to be 9.8 g/cm3, which yielded the best fit with the actual measurements. We demonstrated the most likely range for the target depth from the CT images of actual patients and, within this range, we identified the optimum physical density at which the measured and calculated values were most consistent with each other.

1 December 2021 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
NMNorifumi Mizuno
Norifumi Mizuno
TITomoko Itazawa
Tomoko Itazawa
TMTomoyuki Masuda
Tomoyuki Masuda
SAShinobu Akiyama
Shinobu Akiyama
JKJiro Kawamori
Jiro Kawamori

21 May 2019 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
NMNorifumi Mizuno
Norifumi Mizuno
RYRyouhei Yamauchi
Ryouhei Yamauchi
JKJiro Kawamori
Jiro Kawamori
TITomoko Itazawa
Tomoko Itazawa
MSMunefumi Shimbo
Munefumi Shimbo
TTTakeo Takahashi
Takeo Takahashi

6 December 2023 in Medical Dosimetry
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
TITomoko Itazawa
Tomoko Itazawa
TKTakako Kobayashi
Takako Kobayashi
SKShiho Kashiyama
Shiho Kashiyama
HAHiroyoshi Akimoto
Hiroyoshi Akimoto
JKJiro Kawamori
Jiro Kawamori

1 December 2020 in Physica Medica
Verified
Journal Article
Closed access
RYRyohei Yamauchi
Ryohei Yamauchi
NMNorifumi Mizuno
Norifumi Mizuno
TITomoko Itazawa
Tomoko Itazawa
JKJiro Kawamori
Jiro Kawamori