Jens Rothenberger

Jens Rothenberger

Auto-generated profile, based on publicly available information

Jens Rothenberger

Department of Plastic Surgery, AGAPLESION Markus Hospital, Frankfurt, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2013 in Microsurgery
Verified
Journal Article
Open access
PDF file
JRJens Rothenberger
Jens Rothenberger
AAAmro Amr
Amro Amr
HSHans‐Eberhard Schaller
Hans‐Eberhard Schaller
ARAfshin Rahmanian‐Schwarz
Afshin Rahmanian‐Schwarz
Background: Despite advances in the monitoring of free flaps, there is still a demand for new technology to detect ischemic complications at an early stage. The aim of the present study was to evaluate the reliability of the O2C‐device in terms of detecting flap failure in commonly used perforator flaps for breast reconstruction.Methods: A total of 34 patients undergoing breast reconstruction were involved in this study. The perfusion dynamics of 23 deep inferior epigastric perforator flaps and 11 superior gluteal arterial perforator flaps were assessed using the O2C‐device, which combines a laser light, to determine blood flow (flow), velocity, and white light to determine hemoglobin oxygenation (SO2) and relative amount of hemoglobin (rHB). Measurements were carried out intra‐operatively after clamping and declamping the perforator vessels. In the post‐operative period measurements were carried out every hour for the first 48 hours and from 3rd to 7th for every 2 hours. These dates were compared to findings of clinical assessment.Results: Several intra‐operative measurements, during the clamping and declamping the different perforator vessels, revealed a high correlation for all parameters: Flow (r = 0.89, P < 0. 05), Velo (r = 0.92, P < 0. 05), SO2 (r =0.84, P <0. 05), and rHB (r =0.83 P < 0.05). Vessel occlusion was detected in five cases, of which three were due to arterial thrombosis and two further cases were due to venous occlusion. Of the five cases, one flap loss caused by venous occlusion was noted.Conclusion: The O2C‐device seems to be a reliable, objective, and non‐invasive device for the monitoring of free flaps. Thus, it may improve flap survival rates by detecting vascular compromise at an early stage. © 2013 Wiley Periodicals, Inc. Microsurgery 33:350–357, 2013.

1 January 2013 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
JRJens Rothenberger
Jens Rothenberger
AAAmro Amr
Amro Amr
JSJennifer Lynn Schiefer
Jennifer Lynn Schiefer
HSHans-Eberhard Schaller
Hans-Eberhard Schaller
ARAfshin Rahmanian-Schwarz
Afshin Rahmanian-Schwarz

29 November 2018 in Microsurgery
Verified
Journal Article
Closed access
PDF file
JRJens Rothenberger
Jens Rothenberger
EREva Maria Ramms
Eva Maria Ramms
FMFabian Medved
Fabian Medved
JKJonas Kolbenschlag
Jonas Kolbenschlag
ADAdrien Daigeler
Adrien Daigeler
MHManuel Held
Manuel Held

8 December 2014 in Wound Repair and Regeneration
Verified
Journal Article
Closed access
PDF file
OLOliver Lotter
Oliver Lotter
MHManuel Held
Manuel Held
JSJennifer Lynn Schiefer
Jennifer Lynn Schiefer
OWOle Werner
Ole Werner
FMFabian Medved
Fabian Medved
JRJens Rothenberger
Jens Rothenberger

2 November 2016 in Wound Repair and Regeneration
Verified
Journal Article
Closed access
PDF file
JRJens Rothenberger
Jens Rothenberger
WPWiebke Petersen
Wiebke Petersen
HSHans‐Eberhard Schaller
Hans‐Eberhard Schaller
MHManuel Held
Manuel Held

18 October 2011 in Microsurgery
Verified
Journal Article
Closed access
PDF file
ARAfshin Rahmanian‐Schwarz
Afshin Rahmanian‐Schwarz
JSJennifer Lynn Schiefer
Jennifer Lynn Schiefer
AAAmro Amr
Amro Amr
JRJens Rothenberger
Jens Rothenberger
HSHans‐Eberhard Schaller
Hans‐Eberhard Schaller
BHBernhard Hirt
Bernhard Hirt