Yi Yin Yu

Yi Yin Yu

Auto-generated profile, based on publicly available information

Yi Yin Yu

Department of Information Display, Kyung Hee University , 26, Kyungdae-ro, Dongdaemun-gu, Seoul 02447, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2022 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
YYYi Yin Yu
Yi Yin Yu
KPKyu Chang Park
Kyu Chang Park
We report on the structural effects of a carbon nanotube based cold cathode electron beam (C-beam) module on focal spot sizes (FSSs) for high resolution x-ray imaging applications without additional focusing components. A simple combination of vertically aligned carbon nanotubes and gate mesh structure achieved FSS of 252 and 410 μm for longitudinal and transverse directions, respectively. As design parameters of the modules, gate offsets, gate hole pitch, and emitter area effects of C-beam modules on FSS were optimized. We expect that our simple but sophisticated C-beam module structure will pave next generation x-ray devices not only for high quality x-ray imaging but cost-effective ways for mass production.

1 March 2023 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
KBKetan Bhotkar
Ketan Bhotkar
YYYi Yin Yu
Yi Yin Yu
JSJaydip Sawant
Jaydip Sawant
RPRavindra Patil
Ravindra Patil
KPKyu Chang Park
Kyu Chang Park
This article discusses the development of a cold cathode electron beam (C-beam) based on vertically aligned carbon nanotubes (VACNTs) and the optimization of field emission (FE) from C-beam architecture design. The characteristics of the electron beam are typically required to match the applications of interest. To study the FE, five distinct multi-array emitter island designs, viz., 65 × 65, 75 × 75, 90 × 90, 100 × 100, and 240 × 240 μm2, were fabricated. The island 240 × 240 μm2 (single island) was divided into a group of four subislands each with dimensions 65 × 65, 75 × 75, 90 × 90, and 100 × 100 μm2. We explored the field-screening effect of these different island designs using experiments and modeling, and we discovered that the size of the island had a significant impact on the FE properties. Moreover, we found that the island’s size significantly affected its I–V properties, with a 75 × 75 μm2 island offering 0.7 mA anode current the best emission current among other islands. Additionally, tungsten cross wire (EN 12543-5), a typical resolution testing object, had its focal spot size (FSS) measured using x-ray imaging, and the lowest FSS of 0.45 and 0.49 mm in both vertical and horizontal directions was obtained. This innovative method has a great deal of promise for developing the next generation of VACNT-based electron sources.

1 March 2023 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
YYYi Yin Yu
Yi Yin Yu
KPKyu Chang Park
Kyu Chang Park
We fabricated a cold cathode-driven x-ray source with vertically aligned carbon nanotubes (VACNTs). Dose and spatial resolution characteristics are compared to commercially available portable x-ray sources, and our system outperformed its counterparts. At the same 1.0 mAs condition, our x-ray source represented a dose rate of 0.37 mGy/s, which is 7.8 and 2.4 times greater than that of the thermionic emitter and paste carbon nanotubes based commercial x-ray sources, respectively. In addition, our x-ray source represented better image resolution by achieving a nominal focal spot size of 0.35 mm. We believe that high quality x-ray properties were attained, thanks to the narrow electron beam divergence and high reduced brightness of the electrons from VACNTs, and that this will open up advanced x-ray applications.

1 December 2021 in Journal of Science: Advanced Materials and Devices
Verified
Journal Article
Open access
YWY.F. Wang
Y.F. Wang
YYY.Y. Yu
Y.Y. Yu
HBH. Belliveau
H. Belliveau
NDN.T.M. Duc
N.T.M. Duc
HSH.X. Shen
H.X. Shen
MPM.H. Phan
M.H. Phan

2 April 2024 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
JSJaydip Sawant
Jaydip Sawant
KBKetan Bhotkar
Ketan Bhotkar
YYYi Yin Yu
Yi Yin Yu
KPKyu Chang Park
Kyu Chang Park
In x-ray imaging, high resolution is essential, particularly in sectors such as medical and industries where the need for nondestructive defect detection is required. Previous research has shown that altering beam design and the number of gates offset holes has an impact on focal spot size (FSS). However, the specific effects of beam size and offset size were not thoroughly assessed. In the present study, the influence of beam size and gate offset size was evaluated by utilizing a cold cathode electron beam. Various beam sizes were employed to achieve a small FSS, and subsequently, the smallest beam was utilized to examine the impact of gate offset size. In doing so, the smallest FSS of 0.25 mm vertical and 0.33 mm horizontal was attained without the utilization of any additional focusing lens. This illustrates that by adjusting the beam size and gate offset size, it is possible to attain a small FSS, facilitating the development of an economically viable x-ray imaging beam.

16 February 2024 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
KBKetan Bhotkar
Ketan Bhotkar
YYYi Yin Yu
Yi Yin Yu
JSJaydip Sawant
Jaydip Sawant
KPKyu Chang Park
Kyu Chang Park
The adoption of vertically aligned carbon nanotubes (VACNTs) as electron emitters in x-ray generation has opened a new path for medical imaging technology advancement. With their outstanding electron emission capabilities, VACNTs provide a distinct advantage in miniaturizing and improving the performance of x-ray devices. This research focuses on the effect of electrical aging on x-ray imaging quality and the dose rate while using VACNTs as the electron source. The study includes a thorough examination of the electrical aging effects on VACNT-based x-ray systems, with an emphasis on changes in emission characteristics, beam stability, and the resulting variations in x-ray output. Experiment results show that electrical aging has a considerable impact on the performance of VACNT-based x-ray sources, with visible changes in electron emission parameters and subsequent consequences on x-ray imaging quality. Furthermore, the study investigates the relationship between electrical aging and the x-ray dose rate, providing vital insights into radiation exposure optimization in medical diagnostics.