A. Elsawy Khalil

A. Elsawy Khalil

Auto-generated profile, based on publicly available information

A. Elsawy Khalil

Electrical Power Engineering Department, Faculty of Engineering, Cairo University, Giza, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in IEEE Access
Verified
Journal Article
Open access
AKA. Elsawy Khalil
A. Elsawy Khalil
TBTarek A. Boghdady
Tarek A. Boghdady
MAM. H. Alham
M. H. Alham
DIDoaa Ibrahim
Doaa Ibrahim
Isolated microgrids (IMGs) power remote areas. However, IMG may lower the frequency stability and increase frequency excursions with low system inertia. Load frequency management ensures system stability. Thus, the paper proposes a novel multi-objective tuning strategy to improve IMG’s load frequency control (LFC) and take the microgrid controller’s control signals into account. Diesel engine generator, fuel cell, battery energy storage system, and renewable energy sources (RESs) like photovoltaic and wind systems make up the IMG. Conventional controllers such as proportional-integral (PI) and proportional integral derivative (PID) are classically tuned based on the standard error criteria as a traditional single-objective tuning approach. Due to the low inertia of the system and the stochastic nature of RES, they cannot act as required under different operating scenarios. Therefore, the PI and PID controllers are tuned using the proposed multi-objective-based tuning approach to reduce the frequency deviations. In addition, anti-windup is applied to the enhanced classic controllers to keep them distant from the nonlinear zone and beyond the source’s physical constraints. The proposed tuning process also considers the maximum practical generation rates for different sources. The recent Artificial Rabbits Optimization (ARO) algorithm is applied to simultaneously adjust the controller parameters for several controlled sources in IMG. Extensive simulations in MATLAB and Simulink confirm the effectiveness of the proposed approach to keep the system stable even when facing high levels of disturbances. In addition, accomplishing sensitivity analysis, severe ±25% changes to the system’s parameters guarantee that the proposed tuning strategy keeps the system stable.

22 September 2025 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
AKA. Elsawy Khalil
A. Elsawy Khalil
JSJoseph S. Sedky
Joseph S. Sedky
AIAhmed M. Ibrahim
Ahmed M. Ibrahim
TBTarek A. Boghdady
Tarek A. Boghdady

3 June 2026 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
SESroor M. Elnady
Sroor M. Elnady
JGJosep M. Guerrero
Josep M. Guerrero
KLKhalil Louassaa
Khalil Louassaa
Abdul AzeemAbdul Azeem
Abdul Azeem
XZXian Zhang
Xian Zhang
AKA. Elsawy Khalil
A. Elsawy Khalil

23 October 2026 in Energy Conversion and Economics
Verified
Journal Article
Open access
JMJing Ma
Jing Ma
XZXian Zhang
Xian Zhang
GWGuibin Wang
Guibin Wang
YYYujian Ye
Yujian Ye
FWFushuan Wen
Fushuan Wen
AKAbdelmonem Elsawy Khalil
Abdelmonem Elsawy Khalil
As active distribution networks (ADNs) become increasingly saturated with intermittent renewable energy sources, maintaining voltage within safe operational limits has become a critical and complex task, requiring advanced control methods beyond traditional rule‐based approaches. This paper proposes a novel voltage control framework that integrates a large language model (LLM) with the soft actor‐critic (SAC) algorithm to enhance the performance of deep reinforcement learning (DRL) in ADNs. The core idea is to leverage the LLM as an external knowledge source during the early stage of training to generate highly interpretable and physically meaningful control action suggestions for key voltage regulation devices. A dynamic action fusion mechanism is designed to combine the LLM‐guided actions with SAC policy outputs. As training progresses, the influence of the LLM gradually diminishes, ultimately yielding a fully autonomous SAC policy. Tests on modified IEEE 33‐ and 123‐bus distribution systems show that the proposed method outperforms the standard SAC in terms of convergence efficiency, voltage deviation reduction and control stability. It effectively mitigates policy oscillations during the early exploration phase and significantly reduces the switching frequency of mechanical devices under the learned policy, thereby contributing to longer equipment service life and higher operational reliability.