Leonardo Folmer Rodrigues da Silva

Leonardo Folmer Rodrigues da Silva

Auto-generated profile, based on publicly available information

Leonardo Folmer Rodrigues da Silva

Department of Biomaterials and Oral Biology School of Dentistry of University of São Paulo São Paulo Brazil

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2022 in Biomaterial Investigations in Dentistry
Verified
Journal Article
Open access
IGIvan Onone Gialain
Ivan Onone Gialain
LSLeonardo Folmer Rodrigues da Silva
Leonardo Folmer Rodrigues da Silva
MTMarlene Kasumi Gantier Takano
Marlene Kasumi Gantier Takano
RBRafael Yagüe Ballester
Rafael Yagüe Ballester
MRMarina G. Roscoe
Marina G. Roscoe
JMJosete Barbosa Cruz Meira
Josete Barbosa Cruz Meira
Statement of the problem: Narrow implants have been recommended in high esthetic demand regions to ensure greater buccal bone thickness (BBT) and minimize soft-tissue recession due to insufficient bone support. However, a limited area of bone-implant interface can increase the risk of peri-implant bone resorption due to occlusal forces. Purpose: This article encourages the use of evidence-based finite element analysis to optimize the aesthetic outcomes in maxillary lateral incisor single-supported implant crown by accurate biomechanical planning. This study aimed to analyze the best implant dimensions that would preserve the maximum BBT and avoid peri-implant bone resorption due to occlusal forces. Materials and methods: A maxilla segment was constructed based on anthropological measurements. Four implant diameters (Ø = 3.25; 3.50; 3.75 or 4.00 mm) and two lengths (L = 10 or 13 mm) were simulated. The occlusal force parameters were defined to simulate clinical conditions. The bone resorption risk analysis was based on Frost’s mechanostat theory altering the strain output to strain energy density (SED). The peri-implant bone resorption risk indexes (PIBRri) were calculated by dividing the average of the top ten SED elements of the cortical and trabecular buccal wall by the pathologic resorption limit for each bone. Results: For trabecular bone, only the model Ø4.00L13 exhibited a low PIBRri. For cortical bone, all models presented a low PIBRri, except for models Ø3.25. Conclusion: The selection of a 3.25 mm dental implant to preserve a 2 mm BBT should be avoided since it generates a high peri-implant bone resorption risk induced by occlusal overload.

20 December 2025 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
LSLeonardo Folmer Rodrigues da Silva
Leonardo Folmer Rodrigues da Silva
IGIvan Onone Gialain
Ivan Onone Gialain
MRMarina G. Roscoe
Marina G. Roscoe
OUOmar Melendres Ugarte
Omar Melendres Ugarte
PCPaolo M. Cattaneo
Paolo M. Cattaneo
JMJosete Barbosa Cruz Meira
Josete Barbosa Cruz Meira
Objective: The use of narrow‐diameter implants has emerged as a strategy to compensate for the reduced bone dimensions of maxillary lateral incisor agenesis (MLIA). This study integrates finite element analysis (FEA) and systematic review (SR) to assess the biomechanical and clinical viability of implant‐supported crowns in MLIA scenarios. Materials and Methods: Three‐dimensional FEA were built, comprising a control and an atrophic model representative of an MLIA case. Simulations were performed using implants with varying diameters and materials. The risk of implant and abutment mechanical failure and bone resorption were evaluated. The SR was designed to evaluate the consistency between in silico predictions and clinical outcomes. Results: Reduced implant diameter was associated with an increased risk of implant fracture and bone resorption. All implants and abutments in the simulated models exhibited stress values below the critical threshold for titanium and zirconia failure, indicating a low mechanical failure risk under simulated conditions. Additionally, among the 25 studies included in the SR, 19 reported successful outcomes for implant therapy, but no zirconia implants were identified. Conclusions: Titanium implants with regular diameter combined with hybrid abutments demonstrated favorable biomechanical behavior and seem a reliable option for MLIA rehabilitation, offering both structural integrity and esthetic benefits. Clinical Significance: The implant–prosthetic rehabilitation of MLIA has demonstrated high reliability and predictability in both esthetic and functional outcomes, especially when performed through a multidisciplinary approach involving orthodontics, periodontics, implantology, and prosthodontists. Long‐term studies are still necessary to validate the longevity and performance of zirconia implants in MLIA.