Ying Jiang

Ying Jiang

Auto-generated profile, based on publicly available information

Ying Jiang

Department of Electromechanical Engineering and Centre for Artificial Intelligence and Robotics University of Macau Macau China

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2023 in Nature
Verified
Journal Article
Closed access
PDF file
YJYing Jiang
Ying Jiang
SJShaobo Ji
Shaobo Ji
JSJing Sun
Jing Sun
JHJianping Huang
Jianping Huang
YLYuanheng Li
Yuanheng Li
XCXiaodong Chen
Xiaodong Chen

4 August 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
HJHaoran Jin
Haoran Jin
ZZZesheng Zheng
Zesheng Zheng
ZCZequn Cui
Zequn Cui
YJYing Jiang
Ying Jiang
GCGeng Chen
Geng Chen
Yuanjin ZhengYuanjin Zheng
Yuanjin Zheng
Quantitative and multiparametric blood analysis is of great clinical importance in cardiovascular disease diagnosis. Although there are various methods to extract blood information, they often require invasive procedures, lack continuity, involve bulky instruments, or have complicated testing procedures. Flexible sensors can realize on-skin assessment of several vital signals, but generally exhibit limited function to monitor blood characteristics. Here, we report a flexible optoacoustic blood ‘stethoscope’ for noninvasive, multiparametric, and continuous cardiovascular monitoring, without requiring complicated procedures. The optoacoustic blood ‘stethoscope’ features the light delivery elements to illuminate blood and the piezoelectric acoustic elements to capture light-induced acoustic waves. We show that the optoacoustic blood ‘stethoscope’ can adhere to the skin for continuous and non-invasive in-situ monitoring of multiple cardiovascular biomarkers, including hypoxia, intravascular exogenous agent concentration decay, and hemodynamics, which can be further visualized with a tailored 3D algorithm. Demonstrations on both in-vivo animal trials and human subjects highlight the optoacoustic blood ‘stethoscope’‘s potential for cardiovascular disease diagnosis and prediction.

4 May 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
PCPingqiang Cai
Pingqiang Cai
Changjin WanChangjin Wan
Changjin Wan
LPLiang Pan
Liang Pan
NMNaoji Matsuhisa
Naoji Matsuhisa
KHKe He
Ke He
XCXiaodong Chen
Xiaodong Chen
Coupling myoelectric and mechanical signals during voluntary muscle contraction is paramount in human–machine interactions. Spatiotemporal differences in the two signals intrinsically arise from the muscular excitation–contraction process; however, current methods fail to deliver local electromechanical coupling of the process. Here we present the locally coupled electromechanical interface based on a quadra-layered ionotronic hybrid (named as CoupOn) that mimics the transmembrane cytoadhesion architecture. CoupOn simultaneously monitors mechanical strains with a gauge factor of ~34 and surface electromyogram with a signal-to-noise ratio of 32.2 dB. The resolved excitation–contraction signatures of forearm flexor muscles can recognize flexions of different fingers, hand grips of varying strength, and nervous and metabolic muscle fatigue. The orthogonal correlation of hand grip strength with speed is further exploited to manipulate robotic hands for recapitulating corresponding gesture dynamics. It can be envisioned that such locally coupled electromechanical interfaces would endow cyber–human interactions with unprecedented robustness and dexterity.

3 October 2025 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
CZChuanzhen Zhao
Chuanzhen Zhao
JPJaeho Park
Jaeho Park
DMDesirée Maulà
Desirée Maulà
YYYujia Yuan
Yujia Yuan
DZDonglai Zhong
Donglai Zhong
ZBZhenan Bao
Zhenan Bao

24 May 2023 in Advanced Functional Materials
Verified
Journal Article
Closed access
DYDan Yang
Dan Yang
GTGongwei Tian
Gongwei Tian
CLCuiyuan Liang
Cuiyuan Liang
ZYZixu Yang
Zixu Yang
QZQinyi Zhao
Qinyi Zhao
Dianpeng QiDianpeng Qi
Dianpeng Qi

26 November 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
Feilong ZhangFeilong Zhang
Feilong Zhang
DLDong Li
Dong Li
CWChangxian Wang
Changxian Wang
ZLZhihua Liu
Zhihua Liu
MYMan Yang
Man Yang
XCXiaodong Chen
Xiaodong Chen
Three-dimensional (3D) architectures have qualitatively expanded the functions of materials and flexible electronics. However, current fabrication techniques for devices constrain their substrates to 2D geometries and current post-shape transformation strategies are limited to heterogenous or responsive materials and are not amenable to free-standing inert plastic films such as polyethylene terephthalate (PET) and polyimide (PI), which are vital substrates for flexible electronics. Here, we realize the shape morphing of homogeneous plastic films for various free-standing 3D frameworks from their 2D precursors by introducing a general strategy based on programming the plastic strain in films under peeling. By modulating the peeling parameters, previously inaccessible free-standing 3D geometries ranging from millimeter to micrometer were predicted theoretically and obtained experimentally. This strategy is applicable to most materials capable of plastic deformation, including polymers, metals, and composite materials, and can even enable 4D transformation with responsive plastic films. Enhanced performance of 3D circuits and piezoelectric systems demonstrates the enormous potential of peeling-induced shape morphing for 3D devices.