Albert Treytl

Albert Treytl

Auto-generated profile, based on publicly available information

Albert Treytl

University for Continuing Education Krems

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2023 in IEEE Sensors Letters
Verified
Journal Article
Open access
TSThilo Sauter
Thilo Sauter
ATAlbert Treytl
Albert Treytl
Today, IoT-based sensor devices are ubiquitous. Being cost effective and easy to deploy, they are also considered for many applications outside their original domain, which was consumer electronics. Factory and process automation, smart buildings and homes, and in general Industry 4.0 are application fields is which the use of IoT technology is gaining popularity, often in addition to existing, classical communication architectures on the operational technology (OT) level. IoT devices, however, typically have a different philosophy for communication and data exchange, which makes them easy to use, but poses security challenges by bypassing established security architectures like the classical defense-in-depth concept defined, for instance, in the IEC 62443 standard. This article highlights today's security needs and concepts in industrial environments. Furthermore, it looks at possible new attack surfaces opened by IoT-based applications and shows ways how to bridge the security gap.

2 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
SCSamir Cerimovic
Samir Cerimovic
HSHarald Steiner
Harald Steiner
FWFlorian Wenig
Florian Wenig
FKFranz Keplinger
Franz Keplinger
We present a thermal flow sensor designed for measuring air as well as water flow velocities in heating, ventilation, and air conditioning (HVAC) systems. The sensor is designed to integrate the flow along the entire diameter of the pipe also quantifying the volume flow rate of the streaming fluid where the calorimetric principle in constant temperature operation is utilized as a readout method. In the constant temperature mode, a controller keeps a specific excess temperature between sensing elements at a constant level resulting in a flow dependent heater voltage. To achieve cost-effective sensors, the fabrication of the transducer is fully based on printed circuit board technology allowing low-cost mass production with different form factors. In addition, 2D-FEM simulations were carried out in order to predict the sensor characteristic of envisaged setups. The simulation enables a fast and easy way to evaluate the sensor’s behaviour in different fluids. The results of the FEM simulations are compared to measurements in real environments, proving the credibility of the model.

21 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SCSamir Cerimovic
Samir Cerimovic
ATAlbert Treytl
Albert Treytl
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Keplinger
Franz Keplinger
TSThilo Sauter
Thilo Sauter
We investigated non-invasive flow rate measurements in heating, ventilation, and air conditioning (HVAC) systems utilizing thermal transduction instead of commonly used ultrasonic techniques. The proposed thermal flow transduction comprises two temperature sensors and a heater, all mounted non-invasively on the outer surface of metal-pipes and, therefore, not disturbing the fluid flow inside. One temperature sensor measures the heater temperature, whereas the other one, mounted upstream of the heater, follows the fluid temperature for reference. The temperature difference (i.e., the heater excess temperature) depends on the fluid flow velocity and can be used to derive the mean volume flow inside the pipe. Experimental characterizations were conducted using two sensor prototypes. Beside output characteristics, other main issues such as dynamic behavior and noise density were investigated in detail. Special attention was paid to error compensation allowing measurements within a large range of fluid temperatures. Measurement results confirm the feasibility of this approach, however with some constraints regarding response time.

7 September 2021
Verified
Conference Paper
Closed access
Henri RuotsalainenHenri Ruotsalainen
Henri Ruotsalainen
ATAlbert Treytl
Albert Treytl
TSThilo Sauter
Thilo Sauter
We present a watermarking scheme for sensor data, which accurately detects sensor voltage manipulation attacks. Due to a low complexity implementation running locally on a microcontroller, the proposed technique is well suited for home automation systems but also IoT systems where lightweight sensor nodes with restricted communication capabilities are commonly applied. The watermarking technique is based on modulating the sensor supply voltage, which embeds the watermark signal into the sensor output voltage. Hence, invasive voltage tampering attempts including ADC grounding and voltage injection attacks can be efficiently detected. According to the performed characterization results, our method is able to distinguish normal operation and an attack condition with approx. 98% accuracy for the entire ADC input voltage range. In a real-world demonstration involving a thermistor based temperature sensor all attack attempts were successfully detected.

24 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SCSamir Cerimovic
Samir Cerimovic
ATAlbert Treytl
Albert Treytl
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
FKFranz Keplinger
Franz Keplinger
TSThilo Sauter
Thilo Sauter
We present a feasibility study on non‐invasive flow rate measurements in heating, ventilation, and air conditioning (HVAC) systems utilizing thermal transduction instead of commonly used ultrasonic techniques. The investigated thermal flow transduction comprises two temperature sensors and a heater, all mounted non‐invasively on the outer pipe surface and, therefore, not disturbing the fluid flow inside. One temperature sensor measures the heater temperature, whereas the other one, mounted upstream of the heater, follows the fluid temperature for reference. The temperature difference (i.e., the heater excess temperature) depends on the fluid velocity and can be used to derive the mean volume flow inside the pipe. In order to visualize and study the temperature field, a finite element method (FEM) model of the system was implemented. Measurements conducted with the sensor prototype confirm the feasibility of this approach.

3 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
TGThomas Glatzl
Thomas Glatzl
RBRoman Beigelbeck
Roman Beigelbeck
SCSamir Cerimovic
Samir Cerimovic
HSHarald Steiner
Harald Steiner
ATAlbert Treytl
Albert Treytl
We present finite element method (FEM) simulations of a thermal flow sensor as well as a comparison to measurement results. The thermal sensor is purely based on printed circuit board (PCB) technology, designed for heating, ventilation, and air conditioning (HVAC) systems. Design and readout method of the sensor enables the possibility to measure the flow velocity in various fluids. 2D-FEM simulations were carried out in order to predict the sensor characteristic of envisaged setups. The simulations enable a fast and easy way to evaluate the sensor’s behaviour in different fluids. The results of the FEM simulations are compared to measurements in a real environment, proving the credibility of the model.