5 June 2023 in IEEE Transactions on Industry Applications
In an islanded microgrid, a grid-forming inverter (GFMI) is required to maintain a stable sinusoidal voltage at nominal frequency and amplitude with minimal distortion regardless of loading conditions. As a result, the accurate design of GFMI control schemes in an islanded microgrid requires accurate understanding of the converter dynamics and system harmonics. Electromagnetic transient (EMT) simulations based on detailed switching models give an accurate picture of the GFMI's behaviour. However, EMT simulations take a relatively long time to produce accurate results in large-scale systems. On the other hand, conventional phasor models are unsuitable for harmonic studies. To address this limitation, this article leverages the dynamic phasor (DP) method to develop a new model of a single-phase GFMI connected to single-phase nonlinear (diode-bridge rectifier) and resistive loads. The benefit of the DP method lies in its inherent feature of transforming time-domain signals into slow-varying or DC signals, thereby enabling faster simulations. In this article, the relationship between the control gains of the proposed DP model and the conventional detailed model is established for the first time through small-signal and frequency-domain-based comparative analyses. User-written codes of the proposed DP model are scripted in MATLAB, and simulations on MATLAB/Simulink show that the proposed DP model results have a high degree of correlation with the detailed switching model results. A significant savings in computation time is exhibited by the proposed DP models. The simulation results are validated against experimental results to confirm the accuracy of the proposed DP model.
14 March 2023 in IEEE Access
The dynamic phasor (DP) method is a useful tool for developing simulation-efficient models suitable for system-level analysis. In this paper, two DP models of a single-phase two-stage grid-connected photovoltaic (PV) system are proposed. In the first DP model (DP-Full), the PV array, PV capacitor, boost converter, DC-link, and MPPT (maximum power point tracking) control are modeled. In the second DP model (DP-Simp), the DC-side model is simplified by aggregating the PV capacitor- and boost inductor dynamics into a first-order function while calculating the MPP voltage and current analytically. The accuracy and execution speed of the two DP models are verified by comparing their performance with those of a detailed switching model simulated in an electromagnetic transient program. Simulation and error calculation results show that there is a good agreement between results from the proposed DP models and the switching model. Simulation studies of a two-bus power system demonstrate the computational advantage of the DP-Simp and DP-Full models over the detailed switching model in a multi-converter scenario. The proposed DP models can be used for the fast-paced transient analysis of distribution grids with high PV penetrations.
7 December 2022 in IEEE Transactions on Power Electronics
This article presents dynamic phasor (DP) models of a single-phase diode-bridge rectifier (DBR). Single-phase DBRs serve as a primary building block of consumer electronics, whether with a simple filter or coupled with additional circuitry to produce unity power factor rectification. Four DP models are proposed, two models (DP-SF and DP-AW) suitable for systems with negligible line inductance and two models (DP-Full and DP-Fund), which can be used when the line inductance causes significant commutation overlap. The proposed models are implemented in MATLAB and simulation results are compared against a detailed switching model simulation. A significant reduction in simulation time is demonstrated by the proposed DP models. The simulation results are validated against experimental data, confirming the accuracy of the proposed modeling approaches.
23 February 2026 in IEEE Access
Large artificial intelligence (AI) training data centers are emerging as significant, highly dynamic digital loads that pose numerous challenges to power system stability. Methods to study and assess their impact are still being developed and have been the focus of numerous industry interest groups. Intended to contribute to bridging this gap, this paper develops a credible impact study for data centers, presenting a dynamic data‑center model that includes an uninterruptible power supply (UPS), co‑generator, cooling system, and a grid-forming (GFM) controlled energy storage system (ESS), with explicit converter and control dynamics. Using electromagnetic transient simulations, two stress scenarios are studied: low‑voltage faults and fast load fluctuations characteristic of AI training. The results show that an adequately tuned and controlled GFM ESS can significantly improve the large load response by reducing frequency overshoot, raising the nadir, shortening settling time, and enhancing post‑fault recovery. Under fast fluctuation AI training load profiles, the ESS also damps active‑power oscillations and reduces torsional shaft‑torque oscillations in the generator train to safe levels. These findings support ESS‑based control as an effective tool for integrating large AI data centers without compromising grid stability.
14 April 2025 in IEEE Open Journal of Power Electronics
To mitigate harmonic current flow in distribution systems, single-phase diode-bridge rectifiers (DBRs) are commonly equipped with active power factor correction (PFC) controllers. Achieving high power quality and dynamic performance in PFC controller design demands a precise understanding of PFC converter behavior. While detailed electromagnetic transient (EMT) simulations provide accurate insights, they are time-consuming. To address this, the dynamic phasor (DP) method offers a more efficient modeling approach for power converters. This paper introduces and explores the DP model of a single-phase boost PFC converter, along with guidelines to integrate it with existing simulation platforms. To overcome challenges arising from differing driving frequencies (line frequency for the DBR and switching frequency for the DC-DC converter) in the DP modeling of boost PFC converters, we employ the sign function to transform the dynamic model of the single-phase DBR and boost DC-DC converter into an equivalent single-phase active rectifier model. Subsequently, we convert this equivalent model into a DP model for the single-phase boost PFC converter. Utilizing small-signal analysis, we establish a systematic design procedure for using the proposed DP model to tune and optimize PFC controller gains. Simulations conducted in MATLAB/Simulink, along with error calculations, demonstrate a strong correlation between the proposed DP model and the detailed EMT model results, while also highlighting significant numerical simulation advantages of the DP model over the detailed EMT model. Experimental results further validate the practical utility of the proposed DP model in tuning control systems for single-phase boost PFC converters.
25 October 2023 in IEEE Open Journal of Industry Applications
Single-phase grid-forming inverters are commonly used in uninterruptible power supply (UPS) systems that feed single-phase critical loads in homes, data centers, and hospitals. With the increasing use of power electronics-interfaced loads, single-phase UPS inverters are being designed to exhibit characteristics such as low total harmonic distortion (THD) in output voltage, fast dynamic response, and strong robustness against large changes in load, to ensure a seamless operation of critical loads. The Lyapunov-function-based control strategy is a popular method to provide these characteristics in UPS inverters. However, most studies and designs related to Lyapunov-function-controlled single-phase UPS inverters are conducted by using detailed switching models. While detailed switching models accurately represent the true dynamics of power converters, simulating these models with nonlinear control schemes requires small time steps to produce accurate results. To address this limitation, we propose a new model of Lyapunov-function-based single-phase grid-forming inverter using the dynamic phasor (DP) method. The DP method transforms time-domain signals into slow-varying signals, enabling the use of larger time steps in simulations, which results in shorter simulation times. In the proposed DP model, the Lyapunov energy function is constructed in the DP domain using the dominant harmonics of the inverter output voltage and output current as state variables. The high accuracy and superior computational speed of the proposed DP model are validated through comparison with results obtained from a detailed model with natural-frame-based Lyapunov-function control. Experimental test results confirm the validity and high accuracy of the proposed DP-based method of modeling Lyapunov-function-controlled single-phase grid-forming inverter.