Xue Lyu

Xue Lyu

Auto-generated profile, based on publicly available information

Xue Lyu

Pacific Northwest National Laboratory, Richland, WA, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2016 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JZJingjing Zhao
Jingjing Zhao
XLXue Lyu
Xue Lyu
YFYang Fu
Yang Fu
XHXiaoguang Hu
Xiaoguang Hu
FLFangxing Li
Fangxing Li
This paper proposes a variable coefficient combined virtual inertia and primary frequency control strategy for doubly fed induction generators (DFIG) in coordination with diesel generator to participate in wind/photovoltaic/diesel microgrid frequency regulation. The frequency response characteristic is analyzed under different wind speeds with corresponding inertia control parameters different. A 10% wind power margin is preserved through overspeed control and pitch angle control to offset the decrease of wind output power after temporary extra power surge, and provide a permanent frequency support for microgrids. The influence of droop control gain setting is also illustrated under different wind velocities. By continuously adjusting the control parameters according to wind speed variation, a variable coefficient method is realized. The method can guarantee an efficient implementation of this strategy in time-varying conditions. Finally, this coordinated control strategy is tested in a storage-independent microgrid with solar, wind, and diesel generators.

3 April 2023 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
XLXue Lyu
Xue Lyu
DGDominic Groß
Dominic Groß
Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. The results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

27 August 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
XLXue Lyu
Xue Lyu
JZJian Zhao
Jian Zhao
YJYouwei Jia
Youwei Jia
ZXZhao Xu
Zhao Xu
KWKit Po Wong
Kit Po Wong
High penetration of wind energy in the modern power system exposes the need of smoothing the fluctuating output power in an effective and conducive way. In this context, this paper proposes two novel control strategies that utilize the self-capability of permanent magnet synchronous generator based wind turbine to realize power smoothing. The first strategy pursues to offer power smoothing support via simultaneous utilization of DC-link voltage control, rotor speed control and pitch angle control. The second control strategy seeks to coordinate the three concerned individual control schemes in a hierarchical manner, where the power smoothing tasks are allocated to individual control modules or their combinations dynamically in line with WT's operation status. Both two strategies are able to provide power smoothing support by fully exploiting wind turbine's self-capability, whereas the second strategy has the merits on 1) reducing the activation frequency of pitch angle control, and 2) enhancing wind energy harvesting. Case studies of the proposed control strategies are carried out to compare and verify their effectiveness in achieving power smoothing.

12 February 2019 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
XLXue Lyu
Xue Lyu
YJYouwei Jia
Youwei Jia
ZXZhao Xu
Zhao Xu
Given the ever-increased penetration of wind power generation in today's power systems, wind farms tend to operate in a dispatchable way to a certain extent by actively fulfilling dispatch orders from system operators. This paper is focused on the challenging issue of coordinating the interactive wind turbines in a wind farm, which are influenced by non-negligible wake effect, to efficiently respond to external dispatch order. To achieve this, a novel control strategy is proposed by 1) effectively allocating power regulation task to individual wind turbines; and 2) utilizing the existing resources (i.e. rotational kinetic energy and pitching capability) of wind turbine to satisfy the dispatch order efficiently and reliably. Extensive case studies on both constant and variable wind speed conditions are carried out to demonstrate the effectiveness of the proposed control strategy. As a comparison, simulations results based on uniform load sharing strategy are also presented. It is exhibited that our proposed strategy has better control performance in terms of total energy harvesting and pitching activation frequency.

27 November 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
XLXue Lyu
Xue Lyu
ZXZhao Xu
Zhao Xu
JZJian Zhao
Jian Zhao
KWKit Po Wong
Kit Po Wong
A novel system frequency support strategy is proposed for the two‐stage three phase photovoltaic generation system, which involves simultaneously utilising a direct current (DC)‐link capacitor and deloading generation output. When frequency variation is detected, the energy stored in an inverter DC‐link capacitor is utilised to enable virtual inertia characteristic for system frequency support. At the same time, a deloading control strategy is also activated to provide system frequency support based on reserved generation beforehand. To address impacts due to the changing working conditions with respect to irradiance and ambient temperature, a variable droop scheme is designed for dynamically adjusting the frequency regulation ability based on deloading. Case studies using a microgrid system embedded with a solar and diesel generator are carried out to verify the effectiveness of the proposed control strategy.

9 January 2025 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
XLXue Lyu
Xue Lyu
WDWei Du
Wei Du
SMSheik Mohammad Mohiuddin
Sheik Mohammad Mohiuddin
YCYunzhi Cheng
Yunzhi Cheng
The critical clearing time is a crucial parameter for assessing the large-signal stability of grid-forming (GFM) inverters. Variations in current limiters can significantly impact an inverter's transient behavior during large disturbances. This letter introduces a method based on the power-angle relationship to evaluate the fault recovery of a droop-controlled GFM inverter under a three-phase bolted fault scenario, considering both the circular current limiter and the virtual impedance method. High-fidelity simulations validate the accuracy of the proposed formulas in estimating the critical clearing time of the GFM inverter