22 July 2022 in Radiological Physics and Technology
20 September 2016 in Physics in Medicine & Biology
For dedicated brain PET, we can significantly improve sensitivity for the cerebrum region by arranging detectors in a compact hemisphere. The geometrical sensitivity for the top region of the hemisphere is increased compared with conventional cylindrical PET consisting of the same number of detectors. However, the geometrical sensitivity at the center region of the hemisphere is still low because the bottom edge of the field-of-view is open, the same as for the cylindrical PET. In this paper, we proposed a helmet PET with add-on detectors for high sensitivity brain PET imaging for both center and top regions. The key point is the add-on detectors covering some portion of the spherical surface in addition to the hemisphere. As the location of the add-on detectors, we proposed three choices: a chin detector, ear detectors, and a neck detector. For example, the geometrical sensitivity for the region-of-interest at the center was increased by 200% by adding the chin detector which increased the size by 12% of the size of the hemisphere detector. The other add-on detectors gave almost the same increased sensitivity effect as the chin detector did. Compared with standard whole-body-cylindrical PET, the proposed geometries can achieve 2.6 times higher sensitivity for brain region even with less than 1/4 detectors. In addition, we conducted imaging simulations for geometries with a diameter of 250 mm and with high resolution depth-of-interaction detectors. The simulation results showed that the proposed geometries increased image quality, and all of the add-on detectors were equivalently effective. In conclusion, the proposed geometries have high potential for widespread applications in high-sensitivity, high-resolution, and low-cost brain PET imaging.
16 November 2022 in Physics in Medicine & Biology
Objective. For PET imaging systems, a smaller detector ring enables less intrinsic spatial resolution loss due to the photon non-collinearity effect as well as better balance between production cost and sensitivity, and a hemispherical detector arrangement is more appropriate for brain imaging than a conventional cylindrical arrangement. Therefore, we have developed a brain-dedicated PET system with a hemispherical detector arrangement, which has been commercialized in Japan under the product name of VRAIN TM . In this study, we evaluated imaging performance of VRAIN. Approach. The VRAIN used 54 detectors to form the main hemispherical unit and an additional half-ring behind the neck. Each detector was composed of a 12 × 12 array of lutetium fine silicate crystals (4.1 × 4.1 × 10 mm 3 ) and a 12 × 12 array of silicon photomultipliers (4 × 4 mm 2 active area) with the one-to-one coupling. We evaluated the physical performance of VRAIN according to the NEMA NU 2–2018 standards. Some measurements were modified so as to fit the hemispherical geometry. In addition, we performed 18 F-FDG imaging in a healthy volunteer. Main results. In the phantom study, the VRAIN showed high resolution for separating 2.2 mm rods, 229 ps TOF resolution and 19% scatter fraction. With the TOF gain for a 20 cm diameter object (an assumed head diameter), the peak noise-equivalent count rate was 144 kcps at 9.8 kBq ml −1 and the sensitivity was 25 kcps MBq −1 . Overall, the VRAIN provided excellent image quality in phantom and human studies. In the human FDG images, small brain nuclei and gray matter structures were clearly visualized with high contrast and low noise. Significance. We demonstrated the excellent imaging performance of VRAIN, which supported the advantages of the hemispherical detector arrangement.
19 November 2020 in Physics in Medicine & Biology
Compton imaging or Compton camera imaging has been studied well, but its advantages in nuclear medicine and molecular imaging have not been demonstrated yet. Therefore, the aim of this work was to compare Compton imaging with positron emission tomography (PET) by using the same imaging platform of whole gamma imaging (WGI). WGI is a concept that combines PET with Compton imaging by inserting a scatterer ring into a PET ring. This concept utilizes diverse types of gamma rays for 3D tomographic imaging. In this paper, we remodeled our previous WGI prototype for small animal imaging, and we developed an image reconstruction method based on a list-mode ordered subset expectation maximization algorithm incorporating detector response function modeling, random correction and normalization (sensitivity correction) for either PET and Compton imaging. To the best of our knowledge, this is the world’s first realization of a full-ring Compton imaging system. We selected 89Zr as an imaging target because a 89Zr nuclide emits a 909 keV single-gamma ray as well as a positron, and we can directly compare Compton imaging of 909 keV photons with PET, a well-established modality. We measured a cylindrical phantom and a small rod phantom filled with 89Zr solutions of 10.3 MBq and 10.2 MBq activity, respectively, for 1 h each. The uniform radioactivity distribution of the cylindrical phantom was reconstructed with normalization in both PET and Compton imaging. Coefficients of variation for region-of-interest values were 4.2% for Compton imaging and 3.3% for PET; the difference might be explained by the difference in the detected count number. The small rod phantom experiment showed that the WGI Compton imaging had spatial resolution better than 3.0 mm at the peripheral region although the center region had lower resolution. PET resolved 2.2 mm rods clearly at any location. We measured a mouse for 1 h, 1 d after injection of 9.8 MBq 89Zr oxalate. The 89Zr assimilated in the mouse bony structures was clearly depicted, and Compton imaging results agreed well with PET images, especially for the region inside the scatterer ring. In conclusion, we demonstrated the performance of WGI using the developed Compton image reconstruction method. We realized Compton imaging with a quality approaching that of PET, which is supporting a future expectation that Compton imaging outperforms PET.
1 March 2019 in Physics in Medicine & Biology
A strong demand is expected for high-sensitivity, high-resolution and low-cost brain positron emission tomography (PET) imaging for early diagnosis of dementia, as well as for general neuroscience studies. Therefore, we have proposed novel geometries of a hemisphere detector arrangement for high-sensitivity brain imaging, in which an add-on detector at the chin position or neck position helps in sensitivity uniformity improvement. In this study, we developed the first prototype system for proof-of-concept using four-layer depth-of-interaction detectors, each of which consisted of 16 × 16 × 4 Zr-doped GSO crystals with dimensions of 2.8 × 2.8 × 7.5 mm 3 and a high-sensitivity 64-channel flat-panel photomultiplier tube. We used 47 detectors to form a hemisphere detector with a hemisphere shape of 25 cm inner diameter and 50 cm outer diameter, and we used seven detectors for each of the add-on detectors. The total detector number of 54 was about one-fourth that of a typical whole-body PET scanner. The hemisphere detector for the prototype system was realized by multiple rings having different numbers of detectors and a cross-shaped top detector unit covering the top. Performance evaluation showed uniform spatial resolutions of 3–4 mm by the filtered back-projection method. Imaging tests of a hot-rod phantom done with an iterative method were able to resolve 2.2 mm rods. Peak sensitivity was measured as more than 10% at a region near the top of the head, which was achieved with the help of the top detector unit. In addition, using the prototype system, we performed the first FDG clinical test with a healthy volunteer. The results showed that the proposed geometries had high potential for realizing high-sensitivity, high-resolution, and low-cost brain PET imaging. As for the add-on detector position, it was shown that the neck position resulted in higher sensitivity and wider field of view (FOV) than the chin position because the add-on detector at the neck position can be placed continuously to the hemisphere detector and close to the FOV.
21 July 2023 in Physics in Medicine & Biology
Objective . Deep image prior (DIP) has recently attracted attention owing to its unsupervised positron emission tomography (PET) image reconstruction method, which does not require any prior training dataset. In this paper, we present the first attempt to implement an end-to-end DIP-based fully 3D PET image reconstruction method that incorporates a forward-projection model into a loss function. Approach . A practical implementation of a fully 3D PET image reconstruction could not be performed at present because of a graphics processing unit memory limitation. Consequently, we modify the DIP optimization to a block iteration and sequential learning of an ordered sequence of block sinograms. Furthermore, the relative difference penalty (RDP) term is added to the loss function to enhance the quantitative accuracy of the PET image. Main results . We evaluated our proposed method using Monte Carlo simulation with [ 18 F]FDG PET data of a human brain and a preclinical study on monkey-brain [ 18 F]FDG PET data. The proposed method was compared with the maximum-likelihood expectation maximization (EM), maximum a posteriori EM with RDP, and hybrid DIP-based PET reconstruction methods. The simulation results showed that, compared with other algorithms, the proposed method improved the PET image quality by reducing statistical noise and better preserved the contrast of brain structures and inserted tumors. In the preclinical experiment, finer structures and better contrast recovery were obtained with the proposed method. Significance. The results indicated that the proposed method could produce high-quality images without a prior training dataset. Thus, the proposed method could be a key enabling technology for the straightforward and practical implementation of end-to-end DIP-based fully 3D PET image reconstruction.