Tianyu Wu

Tianyu Wu

Auto-generated profile, based on publicly available information

Tianyu Wu

School of Design Southern University of Science and Technology 518055 Shenzhen Guangdong China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in Materials & Design
Verified
Journal Article
Open access
TWTianyu Wu
Tianyu Wu
YDYujian Dong
Yujian Dong
XLXiaobo Liu
Xiaobo Liu
XHXudong Han
Xudong Han
YXYang Xiao
Yang Xiao
CSChaoyang Song
Chaoyang Song

30 July 2025 in Soft Science
Verified
Journal Article
Open access
PDF file
CDChengxiao Dong
Chengxiao Dong
XDXuanyi Dai
Xuanyi Dai
YPYu Pan
Yu Pan
WQWanghongjie Qiu
Wanghongjie Qiu
SLSen Li
Sen Li
FWFang Wan
Fang Wan
This paper presents a novel, cost-effective sensor platform based on Vision-based Deformation Perception (VBDeformP) for community oral health education. The system integrates a 3D-printed thermoplastic polyurethane soft structure with a rigid resin frame and an ArUco marker to encode interaction information, including the contact region and six-dimensional force and torque. By transforming force estimation into a marker-based pose tracking problem, the VBDeformP sensor achieves accurate and robust force/torque inference under both quasi-static and dynamic conditions, utilizing machine learning models. An adaptive image binarization algorithm extends reliable marker detection across a wide illumination range (10-5,000 lx), ensuring consistent performance of the vision system in realistic community teaching scenarios. Experimental validation involving 10 healthy participants per-forming standardized brushing tasks demonstrated that the sensor attains measurement accuracies comparable to a commercial ATI Axia80-M20 sensor, with mean absolute errors of 0.55 N (2.19% relative error) and 0.067 N·m (2.68% relative error) for quasi-static forces and torques, and 0.16 N (4.10% relative error) and 0.023 N·m (5.75% relative error) under dynamic conditions. Moreover, the system’s real-time brushing region classification algorithm achieved an overall accuracy of 98.12%, further underscoring its potential to provide immediate and personalized guidance on oral hygiene. Its low cost, rapid initialization, portability, and scalable fabrication render it a promising solution for enhancing oral health education in community settings.