Tianpeng Wang

Tianpeng Wang

Auto-generated profile, based on publicly available information

Tianpeng Wang

Xiamen Univ, Pen Tung Sah Inst Micronano Sci & Technol, Xiamen 361102, Peoples R China

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2006 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
XLXinming Liu
Xinming Liu
CSC.C. Shaw
C.C. Shaw
MAM.C. Altunbas
M.C. Altunbas
TWTianpeng Wang
Tianpeng Wang
This paper describes and demonstrates an electronic collimation method, referred to as the alternate line erasure and readout (ALER) technique, for implementing slot-scan digital radiography technique with an amorphous silicon (a-Si) thin-film transistor (TFT) array based flat-panel detector. An amorphus selenium (a-Se) flat-panel detector was modified to implement the ALER technique for slot-scan imaging. A stepping-motor driven fore-collimator was mounted in front of an X-ray tube to generate a scanning X-ray fan beam. The scanning speed and magnification were adjusted to synchronize the fan beam motion with the image line readout rate. The image lines on the leading and trailing edges of the fan beam were tracked and alternately reset and read out, respectively. The former operation resulted in the erasure of the scatter signals accumulated in the leading edge image line prior to the arrival of the fan beam. The latter operation resulted in the acquisition of fan beam exposure data integrated in the trailing edge image line right after the fan beam passed. To demonstrate the scatter rejection capability of this technique, an anthropomorphic chest phantom was placed in PA position and scanned at a speed of 576 lines (8.0 cm)/s at 117 kVp and 32 mA. A tungsten bar is placed at the entrance side of the chest phantom to measure the scatter-to-primary ratio (SPR), scatter reduction factor (SRF), and contrast-to-noise ratio degradation factor (CNRDF) in the slot-scan images to evaluate the effectiveness of scatter rejection and the resultant improvement of image quality. SPR and CNRDF in the open-field images were also measured and used as the reference for comparison. A scatter reduction by 86.4 to 95.4% across lower lung and heart regions has been observed with slot-scan imaging. The CNRs have been found to be improved by a factor of 2 in the mediastinum areas over the open-field image as well.

14 December 2010 in Medical Physics
Verified
Journal Article
Open access
XLXinming Liu
Xinming Liu
CSChris C. Shaw
Chris C. Shaw
CLChao‐Jen Lai
Chao‐Jen Lai
TWTianpeng Wang
Tianpeng Wang
Purpose: To investigate and compare the scatter rejection properties and low‐contrast performance of the scan equalization digital radiography (SEDR) technique to the slot‐scan and conventional full‐field digital radiography techniques for chest imaging.Methods: A prototype SEDR system was designed and constructed with an a‐Se flat‐panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot‐scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24‐segment beam width modulator was developed to regulate x‐ray exposures regionally and compensate for the low x‐ray flux in heavily attenuating regions. To measure the scatter‐to‐primary ratios (SPRs), a 2 mm thick lead plate with a 2‐D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2‐D array of aluminum beads (3 mm in diameter) was used as the low‐contrast objects to measure the contrast ratios (CRs) and contrast‐to‐noise ratios (CNRs) for evaluating the low‐contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot‐scan images and full‐field images acquired with and without antiscatter grid.Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full‐field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot‐scan, and full‐field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full‐field imaging by 259%, 279%, and 145% for SEDR, slot‐scan, and full‐field with grid, respectively. The average CNR over four regions was found to improve over that for nongrid full‐field imaging by 201% for SEDR as compared to 133% for the slot‐scan technique and 14% for the antiscatter grid method.Conclusions: Both SEDR and slot‐scan techniques outperformed the antiscatter grid method used in standard full‐field radiography. For imaging with the same effective exposure, the SEDR technique offers no advantage over the slot‐scan method in terms of SPRs and CRs. However, it improves CNRs significantly, especially in heavily attenuating regions. The improvement of low‐contrast performance may help improve the detection of the lung nodules or other abnormalities and may offer SEDR the potential for dose reduction in chest radiography.

1 March 1999 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TWTianpeng Wang
Tianpeng Wang
CSC.C. Shaw
C.C. Shaw
CLChing-Chung Li
Ching-Chung Li
The computed radiography (CR) technique, also known as the storage phosphor imaging technique, has evolved to be a major candidate for large-scale implementation of digital radiography during the past decade. In order to obtain a reasonable spatial resolution, the storage phosphor plate used is generally limited in thickness. This leads to X rays being only partially absorbed by the detector. Useful information may be contained in the X rays transmitted through the detector. Multiple-plate imaging techniques may be used to capture and utilize the X rays more efficiently. In this paper, an image fusion method, based on the Rayleigh principle and the Karhunen-Loeve (K-L) transform, is presented for optimizing the signal-to-noise ratio (SNR) of the fused image on a pixel-by-pixel basis. Because the multiple-plate images contain the same structural information, the signal components of the images are highly correlated with one another. Thus, the K-L transform is applied to decompose each of the multiple-plate images into an eigen image (the estimated signal) and a residual image (the estimated noise). An average representation entropy measure is maximized for selecting the number of eigen components to be included in the signal estimation. An experimental study, using an anthropomorphic chest phantom, is presented to illustrate pixelwise fusion of multiple-plate images. Experimental results show that the SNR of the fused image was improved by 12-48%, depending upon the anatomical regions of interest in the image.

18 March 2024 in Vacuum
Verified
Journal Article
Closed access
TWTianpeng Wang
Tianpeng Wang
KZKang Zheng
Kang Zheng
DGDandan Gu
Dandan Gu
WLWenlong Lv
Wenlong Lv
LWLingyun Wang
Lingyun Wang

6 September 2024 in Vacuum
Verified
Journal Article
Closed access
KZKang Zheng
Kang Zheng
TWTianpeng Wang
Tianpeng Wang
MWMuhan Wu
Muhan Wu
DGDandan Gu
Dandan Gu
WLWenlong Lv
Wenlong Lv
LWLingyun Wang
Lingyun Wang