Daniel Wedekind

Daniel Wedekind

Auto-generated profile, based on publicly available information

Daniel Wedekind

Institute of Biomedical Engineering, TU Dresden, Fetscherstraße 29, 01307, Dresden, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ATAlexander Trumpp
Alexander Trumpp
JLJohannes Lohr
Johannes Lohr
DWDaniel Wedekind
Daniel Wedekind
MSMartin Schmidt
Martin Schmidt
MBMatthias Burghardt
Matthias Burghardt
SZSebastian Zaunseder
Sebastian Zaunseder
Camera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment. We recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity. The results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations. The proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.

1 March 2017 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
DWDaniel Wedekind
Daniel Wedekind
ATAlexander Trumpp
Alexander Trumpp
FGFrederik Gaetjen
Frederik Gaetjen
SRStefan Rasche
Stefan Rasche
KMKlaus Matschke
Klaus Matschke
SZSebastian Zaunseder
Sebastian Zaunseder
Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.

1 September 2017 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ATAlexander Trumpp
Alexander Trumpp
SRStefan Rasche
Stefan Rasche
DWDaniel Wedekind
Daniel Wedekind
MRMatthias Rudolf
Matthias Rudolf
HMHagen Malberg
Hagen Malberg
SZSebastian Zaunseder
Sebastian Zaunseder
Camera-based photoplethysmography (cbPPG) is an innovative measuring technique that enables the remote extraction of vital signs using video cameras. Most studies in the field focus on heart rate detection while other physiological quantities are often ignored. In this work, we analyzed the relation between the pulse pressure and the pulsation strengths of cbPPG signals for 70 patients after surgery. Our results show a high correlation between the two measures (r = 0.54). Furthermore, the influence of technical and medical factors was tested. The controlled impact of these factors proved to enhance the correlation by between 9 and 27 %.

26 January 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
DWDaniel Wedekind
Daniel Wedekind
DKDenis Kleyko
Denis Kleyko
EOEvgeny Osipov
Evgeny Osipov
HMHagen Malberg
Hagen Malberg
SZSebastian Zaunseder
Sebastian Zaunseder
UWUrban Wiklund
Urban Wiklund
Objective: Novel minimum-contact vital signs monitoring techniques like textile or capacitive electrocardiogram (ECG) provide new opportunities for health monitoring. These techniques are sensitive to artifacts and require handling of unstable signal quality. Spatio-temporal Blind Source Separation (BSS) is capable of processing suchlike multichannel signals. However, BSS's permutation indeterminacy requires the selection of the cardiac signal (i.e. the component resembling the electric cardiac activity) after its separation from artifacts. This study evaluates different concepts for solving permutation indeterminacy. Methods: Novel automated component selection routines based on heartbeat detections are compared with standard concepts, as using higher order moments or frequency-domain features, for solving permutation indeterminacy in spatio-temporal BSS. BSS was applied to a textile and a capacitive ECG dataset of healthy subjects performing a motion protocol, and to the MIT-BIH Arrhythmia Database. The performance of the subsequent component selection was evaluated by means of the heartbeat component. Results: The proposed heartbeat-detection-based selection routines significantly outperformed the standard selectors based on Skewness, Kurtosis and frequency-domain features, especially for datasets containing motion artifacts. For arrhythmia data, beat analysis by sparse coding outperformed simple periodicity tests of the detected heartbeats. Conclusions: Component selection routines based on heartbeat detections are capable of reliably selecting cardiac signals after spatio-temporal BSS in case of severe motion artifacts and arrhythmia. Significance: The availability of robust cardiac component selectors for solving permutation indeterminacy facilitates the usage of spatio-temporal BSS to extract cardiac signals in artifact-sensitive minimum-contact vital signs monitoring techniques.