Rad Zdero

Rad Zdero

Auto-generated profile, based on publicly available information

Rad Zdero

Martin Orthopaedic Biomechanics Laboratory, St Michael's Hospital, Toronto, Ontario, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2010 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JLJames P. Lever
James P. Lever
RZRad Zdero
Rad Zdero
MNMarkku T. Nousiainen
Markku T. Nousiainen
JWJames P. Waddell
James P. Waddell
ESEmil H. Schemitsch
Emil H. Schemitsch
Background: A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty.Methods: Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values.Results: All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05).Conclusions: Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.

1 December 2010 in Journal of Trauma: Injury, Infection & Critical Care
Verified
Journal Article
Closed access
RZRad Zdero
Rad Zdero
OKOliver Keast-Butler
Oliver Keast-Butler
ESEmil H. Schemitsch
Emil H. Schemitsch
Fixation of femoral neck fractures is often accomplished by several screws inserted along the neck axis. Alignment and number of screws remain at the discretion of the surgeon. Two fracture repair methods were compared. Sixteen large, left, adult, synthetic femurs, known as Third Generation Composite Femurs (Pacific Research Laboratories, Vashon, WA), were osteotomized with a transverse cut perpendicular to the neck axis. Fractures were reduced and repaired using method 1 (n = 8) or method 2 (n = 8) cannulated cancellous screw methods. Method 1 screws were inserted parallel in an upside-down triangle configuration and abutted against the cortical walls inferiorly, anteriorly, and posteriorly. Method 2 screws were placed adjacent to one another as often done clinically. Femoral shafts were positioned in a nonclinical vertical orientation to obtain conservative "lower bound" measurements. Specimens were tested for torsional and axial stiffness using subclinical loads followed by axial failure tests. Method 1 showed statistically higher values compared with method 2 for torsional stiffness (9.9 vs. 7.9 Nm/deg, method 1/method 2 ratio = 1.25, p = 0.018), axial stiffness (1469.0 vs. 1278.1 N/mm, method 1/method 2 ratio = 1.15, p = 0.023), and axial failure load (3493.5 vs. 2863.5 N, method 1/method 2 ratio = 1.22, p = 0.000). However, there were no statistical differences in axial failure displacement (10.9 vs. 16.9 mm, method 1/method 2 ratio = 0.64, p = 0.101) or axial failure energy (29.9 vs. 35.9 J, method 1/method 2 ratio = 0.83, p = 0.453). For both methods, femoral heads move distally while screw shafts cut through the spongy cancellous matrix of the femoral neck in knife-like fashion. Method 1 was more mechanically stable than method 2 in femoral neck fracture fixation as detected by three of five biomechanical measurements and equivalent to method 2 for two of five biomechanical measurements.

1 December 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TMTroy MacAvelia
Troy MacAvelia
MSMeisam Salahi
Meisam Salahi
MOMichael Olsen
Michael Olsen
MCMeghan Crookshank
Meghan Crookshank
ESEmil H. Schemitsch
Emil H. Schemitsch
RZRad Zdero
Rad Zdero
Few experimental studies have examined surgical drilling in human bone, and no studies have inquired into this aspect for a popular commercially-available artificial bone used in biomechanical studies. Sixteen fresh-frozen human femurs and five artificial femurs were obtained. Cortical specimens were mounted into a clamping system equipped with a thrust force and torque transducer. Using a CNC machine, unicortical holes were drilled in each specimen at 1000 rpm, 1250 rpm, and 1500 rpm with a 3.2 mm diameter surgical drill bit. Feed rate was 120 mm/min. Statistical significance was set at p < 0.05. Force at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (198.4 ± 14.2 N, 180.6 ± 14.0 N, and 176.3 ± 11.2 N) and artificial femurs (87.2 ± 19.3 N, 82.2 ± 11.2 N, and 75.7 ± 8.8 N). For human femurs, force at 1000 rpm was greater than at other speeds (p ≤ 0.018). For artificial femurs, there was no speed effect on force (p ≥ 0.991). Torque at increasing spindle speed (1000 rpm, 1250 rpm, and 1500 rpm), respectively, showed a range for human femurs (186.3 ± 16.9 N·mm, 157.8 ± 16.1 N·mm, and 140.2 ± 16.4 N·mm) and artificial femurs (67.2 ± 8.4 N·mm, 61.0 ± 2.9 N·mm, and 53.3 ± 2.9 N·mm). For human femurs, torque at 1000 rpm was greater than at other speeds (p < 0.001). For artificial femurs, there was no difference in torque for 1000 rpm versus higher speeds (p ≥ 0.228), and there was only a borderline difference between the higher speeds (p = 0.046). Concerning human versus artificial femurs, their behavior was different at every speed (force, p ≤ 0.001; torque, p < 0.001). For human specimens at 1500 rpm, force and torque were linearly correlated with standardized bone mineral density (sBMD) and the T-score used to clinically categorize bone quality (R ≥ 0.56), but there was poor correlation with age at all speeds (R ≤ 0.37). These artificial bones fail to replicate force and torque in human cortical bone during surgical drilling. To date, this is the largest series of human long bones biomechanically tested for surgical drilling.

1 December 2011 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
RWRichard M Walker
Richard M Walker
RZRad Zdero
Rad Zdero
MMMichael D MD McKee
Michael D MD McKee
JWJames P Md Waddell
James P Md Waddell
ESEmil H Md Schemitsch
Emil H Md Schemitsch
Objectives: The aim of the study was to investigate how superior entry point varies with tibial rotation and to identify landmarks that can be used to identify suitable radiographs for successful intramedullary nail insertion. Methods: The proximal tibia and knee were imaged for 12 cadaveric limbs undergoing 5° increments of internal and external rotation. Medial and lateral arthrotomies were performed, the ideal superior entry point was identified, and a 2-mm Kirschner wire inserted. A second Kirschner wire was sequentially placed at the 5-mm and then the 10-mm position, both medial and lateral to the initial Kirschner wire. Radiographs of the knee were obtained for all increments. The changing position of the ideal nail insertion point was recorded. Results: A 30° arc (range, 25°–40°) provided a suitable anteroposterior radiograph. On the neutral anteroposterior radiograph, the Kirschner wire was 54% ± 1.5% (range, 51–56%) from the medial edge of the tibial plateau. For every 5° of rotation, the Kirschner wire moved 3% of the plateau width. During external rotation, a misleading medial entry point was obtained. A fibular bisector line correlated with an entry point that was ideal or up to 5 mm lateral to this but never medial. The film that best showed the fibular bisector line was between 0° and 10° of internal rotation of the tibia. Conclusions: The fibula head bisector line can be used to avoid choosing external rotation views and, thus, avoid medial insertion points. The current results may help the surgeon prevent malalignment during intramedullary nailing in proximal tibial fractures.

1 July 2011 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
HBHabiba Bougherara
Habiba Bougherara
EREhsan Rahim
Ehsan Rahim
SSSuraj Shah
Suraj Shah
ADAnton Dubov
Anton Dubov
ESEmil H. Schemitsch
Emil H. Schemitsch
RZRad Zdero
Rad Zdero
With the resurgence of composite materials in orthopaedic applications, a rigorous assessment of stress is needed to predict any failure of bone-implant systems. For current biomechanics research, strain gage measurements are employed to experimentally validate finite element models, which then characterize stress in the bone and implant. Our preliminary study experimentally validates a relatively new nondestructive testing technique for orthopaedic implants. Lock-in infrared (IR) thermography validated with strain gage measurements was used to investigate the stress and strain patterns in a novel composite hip implant made of carbon fiber reinforced polyamide 12 (CF/PA12). The hip implant was instrumented with strain gages and mechanically tested using average axial cyclic forces of 840 N, 1500 N, and 2100 N with the implant at an adduction angle of 15 deg to simulate the single-legged stance phase of walking gait. Three-dimensional surface stress maps were also obtained using an IR thermography camera. Results showed almost perfect agreement of IR thermography versus strain gage data with a Pearson correlation of R2 = 0.96 and a slope = 1.01 for the line of best fit. IR thermography detected hip implant peak stresses on the inferior-medial side just distal to the neck region of 31.14 MPa (at 840 N), 72.16 MPa (at 1500 N), and 119.86 MPa (at 2100 N). There was strong correlation between IR thermography-measured stresses and force application level at key locations on the implant along the medial (R2 = 0.99) and lateral (R2 = 0.83 to 0.99) surface, as well as at the peak stress point (R2 = 0.81 to 0.97). This is the first study to experimentally validate and demonstrate the use of lock-in IR thermography to obtain three-dimensional stress fields of an orthopaedic device manufactured from a composite material.

1 February 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AAAhmed Al-Jahwari
Ahmed Al-Jahwari
ESEmil H. Schemitsch
Emil H. Schemitsch
JWJay S. Wunder
Jay S. Wunder
PFPeter C. Ferguson
Peter C. Ferguson
RZRad Zdero
Rad Zdero
In the presence of a tumor defect, completed humeral shaft fractures continue to be a major surgical challenge since there is no “gold standard” treatment. This is due, in part, to the fact that only one prior biomechanical study exists on the matter, but which only compared 2 repair methods. The current authors measured the humeral torsional performance of 5 fixation constructs for completed pathological fractures. In 40 artificial humeri, a 2-cm hemi-cylindrical cortical defect with a transverse fracture was created in the lateral cortex. Specimens were divided into 5 different constructs and tested in torsion. Construct A was a broad 10-hole 4.5-mm dynamic compression plate (DCP). Construct B was the same as A except that the screw holes and the tumor defect were filled with bone cement and the screws were inserted into soft cement. Construct C was the same as A except that the canal and tumor defect were filled with bone cement and the screws were inserted into dry cement. Construct D was a locked intramedullary nail inserted in the antegrade direction. Construct E was the same as D except that bone cement filled the defect. For torsional stiffness, construct C (4.45 ± 0.20 Nm/deg) was not different than B or E (p > 0.16), but was higher than A and D (p < 0.001). For failure torque, construct C achieved a higher failure torque (69.65 ± 5.35 Nm) than other groups (p < 0.001). For the failure angle, there were no differences between plating constructs A to C (p ≥ 0.11), except for B versus C (p < 0.05), or between nailing groups D versus E (p = 0.97), however, all plating groups had smaller failure angles than both nailing groups (p < 0.05). For failure energy, construct C (17.97 ± 3.59 J) had a higher value than other groups (p < 0.005), except for A (p = 0.057). Torsional failure always occurred in the bone in the classic “spiral” pattern. Construct C provided the highest torsional stability for a completed pathological humeral shaft fracture.