James P. Waddell

James P. Waddell

Auto-generated profile, based on publicly available information

James P. Waddell

St. Michael’s Hospital, University of Toronto, Toronto, Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2015 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
CSClaudia C. Sidler-Maier
Claudia C. Sidler-Maier
JWJames P. Waddell
James P. Waddell

23 July 2010 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JLJames P. Lever
James P. Lever
RZRad Zdero
Rad Zdero
MNMarkku T. Nousiainen
Markku T. Nousiainen
JWJames P. Waddell
James P. Waddell
ESEmil H. Schemitsch
Emil H. Schemitsch
Background: A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty.Methods: Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values.Results: All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05).Conclusions: Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.

18 June 2021 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
ABAndrew M Briggs
Andrew M Briggs
CSCarmen Huckel Schneider
Carmen Huckel Schneider
HSHelen Slater
Helen Slater
JJJoanne E Jordan
Joanne E Jordan
SPSarika Parambath
Sarika Parambath
LMLyn March
Lyn March
Introduction Despite the profound burden of disease, a strategic global response to optimise musculoskeletal (MSK) health and guide national-level health systems strengthening priorities remains absent. Auspiced by the Global Alliance for Musculoskeletal Health (G-MUSC), we aimed to empirically derive requisite priorities and components of a strategic response to guide global and national-level action on MSK health. Methods Design: mixed-methods, three-phase design. Phase 1: qualitative study with international key informants (KIs), including patient representatives and people with lived experience. KIs characterised the contemporary landscape for MSK health and priorities for a global strategic response. Phase 2: scoping review of national health policies to identify contemporary MSK policy trends and foci. Phase 3: informed by phases 1–2, was a global eDelphi where multisectoral panellists rated and iterated a framework of priorities and detailed components/actions. Results Phase 1: 31 KIs representing 25 organisations were sampled from 20 countries (40% low and middle income (LMIC)). Inductively derived themes were used to construct a logic model to underpin latter phases, consisting of five guiding principles, eight strategic priority areas and seven accelerators for action. Phase 2: of the 165 documents identified, 41 (24.8%) from 22 countries (88% high-income countries) and 2 regions met the inclusion criteria. Eight overarching policy themes, supported by 47 subthemes, were derived, aligning closely with the logic model. Phase 3: 674 panellists from 72 countries (46% LMICs) participated in round 1 and 439 (65%) in round 2 of the eDelphi. Fifty-nine components were retained with 10 (17%) identified as essential for health systems. 97.6% and 94.8% agreed or strongly agreed the framework was valuable and credible, respectively, for health systems strengthening. Conclusion An empirically derived framework, co-designed and strongly supported by multisectoral stakeholders, can now be used as a blueprint for global and country-level responses to improve MSK health and prioritise system strengthening initiatives.

1 June 2015 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
FWF. Webster
F. Webster
APA.V. Perruccio
A.V. Perruccio
RJR. Jenkinson
R. Jenkinson
SJS. Jaglal
S. Jaglal
ESE. Schemitsch
E. Schemitsch
ADA.M. Davis
A.M. Davis

1 September 2012 in Bone & Joint Research
Verified
Journal Article
Open access
AAA. Atrey
A. Atrey
ZMZ. Morison
Z. Morison
TTT. Tosounidis
T. Tosounidis
JTJ. Tunggal
J. Tunggal
JWJ. P. Waddell
J. P. Waddell
We systematically reviewed the published literature on the complications of closing wedge high tibial osteotomy for the treatment of unicompartmental osteoarthritis of the knee. Publications were identified using the Cochrane Library, MEDLINE, EMBASE and CINAHL databases up to February 2012. We assessed randomised (RCTs), controlled group clinical (CCTs) trials, case series in publications associated with closing wedge osteotomy of the tibia in patients with osteoarthritis of the knee and finally a Cochrane review. Many of these trials included comparative studies (opening wedge versus closing wedge) and there was heterogeneity in the studies that prevented pooling of the results.

23 December 2013 in BMC Health Services Research
Verified
Journal Article
Open access
PDF file
FWFiona Webster
Fiona Webster
APAnthony V Perruccio
Anthony V Perruccio
RJRichard Jenkinson
Richard Jenkinson
SJSusan Jaglal
Susan Jaglal
ESEmil Schemitsch
Emil Schemitsch
ADAileen M Davis
Aileen M Davis
Patient-centered care ideally considers patient preferences, values and needs. However, it is unclear if policies such as wait time strategies for hip and knee replacement surgery (TJR) are patient-centred as they focus on an isolated episode of care. This paper describes the accounts of people scheduled to undergo TJR, focusing on their experience of (OA) as a chronic disease that has considerable impact on their everyday lives.