Drift tube ion mobility spectrometers (IMS) are widely used for fast trace gas detection in air, but portable compact systems are typically very limited in their resolving power. Decreasing the initial ion packet width improves the resolution, but is generally associated with a reduced signal-to-noise-ratio (SNR) due to the lower number of ions injected into the drift region. In this paper, we present a refined theory of IMS operation which employs a combined approach for the analysis of the ion drift and the subsequent amplification to predict both the resolution and the SNR of the measured ion current peak. This theoretical analysis shows that the SNR is not a function of the initial ion packet width, meaning that compact drift tube IMS with both very high resolution and extremely low limits of detection can be designed. Based on these implications, an optimized combination of a compact drift tube with a length of just 10 cm and a transimpedance amplifier has been constructed with a resolution of 183 measured for the positive reactant ion peak (RIP+), which is sufficient to e.g. separate the RIP+ from the protonated acetone monomer, even though their drift times only differ by a factor of 1.007. Furthermore, the limits of detection (LODs) for acetone are 180 pptv within 1 s of averaging time and 580 pptv within only 100 ms.
8 April 2019 in Analytical and Bioanalytical Chemistry
Ion mobility spectrometry provides ion separation in the gas phase mainly based on differing ion-neutral collision cross sections, enabling powerful analysis of many isomers. However, the separation also has a miniscule mass dependence due to the acceleration and collision properties. In this work, we show for the first time that using a compact ultra-high-resolution ion mobility spectrometer with a resolving power of 250 and an UV ionization source enables the separation of isotopologues with ion mobility spectrometry. This is demonstrated for regular and perdeuterated acetone, benzene, and toluene as well as toluene-13C7 in nitrogen and in purified air as drift gas. The observed peak shifts in the ion mobility spectrum agree with the basic ion mobility equation when using nitrogen as drift gas and also agree with a combination of this equation with Blanc’s law when using purified air as drift gas. For benzene and toluene, a reduction in the ion-neutral collision cross section of the isotopically replaced species is observed. Furthermore, a third peak formed from regular and perdeuterated acetone is observed, which can most likely be attributed to the exchange of a methyl group.
17 May 2014 in International Journal for Ion Mobility Spectrometry