Philip Jarrett

Philip Jarrett

Auto-generated profile, based on publicly available information

Philip Jarrett

Department of Emergency Medicine, The University of Texas Southwestern Medical Center, Dallas, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2016 in Plant and Cell Physiology
Verified
Journal Article
Open access
PDF file
NPNecla Pehlivan
Necla Pehlivan
LSLi Sun
Li Sun
PJPhilip Jarrett
Philip Jarrett
XYXiaojie Yang
Xiaojie Yang
NMNeelam Mishra
Neelam Mishra
HZHong Zhang
Hong Zhang
The Arabidopsis gene AtNHX1 encodes a vacuolar membrane-bound sodium/proton (Na+/H+) antiporter that transports Na+ into the vacuole and exports H+ into the cytoplasm. The Arabidopsis gene SOS1 encodes a plasma membrane-bound Na+/H+ antiporter that exports Na+ to the extracellular space and imports H+ into the plant cell. Plants rely on these enzymes either to keep Na+ out of the cell or to sequester Na+ into vacuoles to avoid the toxic level of Na+ in the cytoplasm. Overexpression of AtNHX1 or SOS1 could improve salt tolerance in transgenic plants, but the improved salt tolerance is limited. NaCl at concentration >200 mM would kill AtNHX1-overexpressing or SOS1-overexpressing plants. Here it is shown that co-overexpressing AtNHX1 and SOS1 could further improve salt tolerance in transgenic Arabidopsis plants, making transgenic Arabidopsis able to tolerate up to 250 mM NaCl treatment. Furthermore, co-overexpression of AtNHX1 and SOS1 could significantly reduce yield loss caused by the combined stresses of heat and salt, confirming the hypothesis that stacked overexpression of two genes could substantially improve tolerance against multiple stresses. This research serves as a proof of concept for improving salt tolerance in other plants including crops.

1 September 2018 in Plant Science
Verified
Journal Article
Open access
LSLi Sun
Li Sun
NPNecla Pehlivan
Necla Pehlivan
NENardana Esmaeili
Nardana Esmaeili
WJWeijia Jiang
Weijia Jiang
XYXiaojie Yang
Xiaojie Yang
HZHong Zhang
Hong Zhang
Abiotic stresses are major threats to agricultural production. Drought and salinity as two of the major abiotic stresses cause billions of losses in agricultural productivity worldwide each year. Thus, it is imperative to make crops more tolerant. Overexpression of AVP1 or PP2A-C5 was previously shown to increase drought and salt stress tolerance, respectively, in transgenic plants. In this study, the hypothesis that co-overexpression of AVP1 and PP2A-C5 would combine their respective benefits and further improve salt tolerance was tested. The two genes were inserted into the same T-DNA region of the binary vector and then introduced into the Arabidopsis genome through Agrobacterium-mediated transformation. Transgenic Arabidopsis plants expressing both AVP1 and PP2A-C5 at relatively high levels were identified and analyzed. These plants displayed enhanced tolerance to NaCl compared to either AVP1 or PP2A-C5 overexpressing plants. They also showed tolerance to other stresses such as KNO3 and LiCl at harmful concentrations, drought, and phosphorus deficiency at comparable levels with either AVP1 or PP2A-C5 overexpressing plants. This study demonstrates that introducing multiple genes in single T-DNA region is an effective approach to create transgenic plants with enhanced tolerance to multiple stresses.

18 January 2026 in medRxiv
Verified
Preprint
Open access
PDF file
SKShinyoung Kang
Shinyoung Kang
MHMichael J. Holcomb
Michael J. Holcomb
ASAmeer H. Shakur
Ameer H. Shakur
DHDavid Hein
David Hein
HNHuong-Tra Ngo
Huong-Tra Ngo
AJAndrew R. Jamieson
Andrew R. Jamieson
Background: The assessment of physical examination skills in medical education is resource-intensive and prone to inter-rater variability. While artificial intelligence (AI) has successfully automated the grading of clinical notes and transcripts, evaluating the physical techniques themselves—what students do rather than what they say—remains an unsolved challenge. We evaluated whether a multimodal AI system could assess physical examination skills with expert-level reliability. Methods: In this retrospective ablation study, we analyzed 300 video-recorded encounters from six Objective Structured Clinical Examination (OSCE) stations (cardiovascular, respiratory, gastrointestinal, musculoskeletal, and neurological). We compared the performance of a multimodal AI model (Gemini 2.5 Pro) across single- and multi-camera configurations and isolated input modalities (video, audio-only, transcript-only, visual-only) against standard human grading. The primary outcome was agreement with a physician-adjudicated ground-truth reference standard, measured by quadratic weighted Cohen’s kappa (κ). Results: The AI system using a synchronized 3-camera native video configuration achieved significantly higher reliability (κ = 0.830; 95% CI, 0.773–0.880) than the standard human evaluators (κ = 0.732; 95% CI, 0.687–0.776). Performance followed a strict hierarchy: native video > audio-only > transcript-only > visual-only. Notably, visual-only models failed (κ ≈ 0.20) despite high detection accuracy, revealing a “visual paradox” where models could identify when an action occurred but not how well it was performed without audio cues. Conclusions: A properly configured multimodal AI system can grade physical examination skills with reliability exceeding that of trained human evaluators. Success requires native processing of synchronized audio-visual streams; transcript-based or visual-only approaches are insufficient for high-stakes assessment. These findings suggest that AI can provide scalable, objective, and valid assessment of clinical skills, overcoming the limitations of traditional human grading. Abstract Figure:

21 August 2026 in Academic Radiology
Verified
Journal Article
Closed access
PJPhilip Jarrett
Philip Jarrett
PKPaolo Eduardo de Aguiar Kuriki
Paolo Eduardo de Aguiar Kuriki
DDDeborah Diercks
Deborah Diercks
MHMichael Holcomb
Michael Holcomb
AJAndrew Jamieson
Andrew Jamieson

6 June 2025 in medRxiv
Verified
Preprint
Open access
PDF file
PJPhilip C. Jarrett
Philip C. Jarrett
JHJared Hill
Jared Hill
MHMarshall Howell
Marshall Howell
KMKristen Grabow Moore
Kristen Grabow Moore
JTJoby J. Thoppil
Joby J. Thoppil
DCDazhe Cao
Dazhe Cao
Objective: To determine the impact of the temperature parameter on GPT-4o’s diagnostic accuracy when evaluating emergency medicine cases and assess the effect on diagnostic divergence across iterations. Methods: We conducted a simulation-based diagnostic accuracy study using four challenging emergency medicine cases adapted from the Foundations of Emergency Medicine curriculum. Each case was submitted to GPT-4o 250 times at five temperature settings (0.0, 0.25, 0.50, 0.75, 1.0), both with and without physical examination findings, yielding 10,000 total outputs. Each output contained exactly three differential diagnoses with one leading diagnosis. Diagnostic accuracy was assessed by comparing outputs against predetermined gold-standard diagnoses. Results: At temperature 0.0, GPT-4o achieved 100% leading diagnosis accuracy across all cases with physical exam data. As temperature increased, accuracy declined systematically to 89.4% at temperature 1.0. Diagnostic divergence increased dramatically from an average of 4.5 unique diagnoses at temperature 0.0 to 26.25 at temperature 1.0 (583% increase). Case sensitivity varied significantly, with ascending cholangitis showing the greatest temperature sensitivity (accuracy dropping from 100% to 70.4%) while carbon monoxide poisoning maintained 100% accuracy across all settings. Discussion: Higher temperatures introduced concerning diagnostic inconsistency rather than beneficial exploration, with substantial accuracy degradation in temperature-sensitive cases. Conclusions: Lower temperature settings promote diagnostic accuracy and consistency, making them preferable for clinical applications requiring high reliability. Transparent reporting of temperature settings is essential for reproducible clinical artificial intelligence research. KEY MESSAGES: What is already known on this topic: Large language models demonstrate promising diagnostic capabilities in medical reasoning tasks, but their non-deterministic nature and sensitivity to parameter settings remain poorly understood in clinical contexts. What this study adds: The temperature parameter significantly affects both diagnostic accuracy and consistency, with higher settings causing dramatic increases in diagnostic divergence. How this study might affect research, practice or policy: These findings mandate transparent reporting of temperature settings in clinical AI research and suggest that low-temperature configurations should be prioritized for high-reliability medical applications.

3 March 2026 in Resuscitation Plus
Verified
Journal Article
Open access
PJPhilip Jarrett
Philip Jarrett
RPRithika Prakash
Rithika Prakash
BTBhaskar Thakur
Bhaskar Thakur
JTJordan Thomas
Jordan Thomas
DCDazhe Cao
Dazhe Cao
AIAhamed Idris
Ahamed Idris
To establish evidence-based peak amplitude thresholds for thoracic bioimpedance monitoring of ventilation and characterize the relationship between peak amplitude and tidal volume across two defibrillator devices used in pre-hospital care during cardiopulmonary resuscitation. Thirty healthy adults underwent mechanical ventilation while thoracic bioimpedance was monitored using LifePak12 and HeartStart MRx defibrillators at five tidal volumes (250-800 mL). Peak amplitude measurements were extracted from thoracic bioimpedance waveforms. Linear mixed-effects models accounted for repeated measurements. Sex-stratified analyses examined device-specific sensitivity differences. Breath detection thresholds were calculated at various target sensitivities. Linear relationships were observed for both devices. The LifePak 12 device showed tidal volume slopes of 0.0022 Ω/mL for females and 0.0013 Ω/mL for males. The HeartStart MRx device demonstrated slopes of 0.0030 Ω/mL for females and 0.0016 Ω/mL for males. Males showed 41-47% lower sensitivity to tidal volume changes than females across both devices. Model performance showed intraclass-correlations of 0.713-0.783 with prediction correlations exceeding 0.97. For the 250 mL breath, peak amplitude thresholds were 0.630/0.40 Ω (female/male) for LifePak12 and 0.45/0.30 Ω for HeartStart MRx at 90% detection sensitivity. This study provides preliminary sex- and device-specific peak amplitude thresholds for breath identification using thoracic bioimpedance waveforms. The observed linear relationships and provided thresholds may improve categorical breath detection in resuscitation research. These findings require validation in cardiac arrest patients to ensure generalizability for clinical application.