25 April 2023 in IEEE Sensors Journal
Water seepage of building walls is a common problem in our lives. However, the lack of early seepage detection methods often makes the problem worse. To develop effective early wall seepage detection methods, an ultra-sensitive quartz crystal microbalance (QCM) humidity sensor based on fullerenol (C 60 -OH)-assisted dispersion of Nafion/multi-walled carbon nanotubes (MWCNTs) composites is proposed. The prepared sensor shows almost 7 times higher frequency shift than pure Nafion-based sensor, which reaches -10814 Hz. This is mainly attributed to the uniform dispersion of MWCNTs in the Nafion with the assistance of C 60 -OH to form a reticular structure that generates more voids, which greatly improves the diffusion ability of water molecules in the composite materials and thus further enhances humidity sensing properties of the sensor. The high-performance QCM humidity sensor is expected to be used for early detection of water seepage in building walls by monitoring air humidity changes near the wall surface.
28 December 2023 in IEEE Transactions on Instrumentation and Measurement
Sensitivity and linearity are two crucial parameters in the context of quartz crystal microbalance (QCM) humidity sensors. Achieving a highly sensitive response in a QCM-based humidity sensor involves employing a significant mass of humidity-sensitive material. However, this approach may introduce a viscosity effect, leading to a nonlinear response from the sensor. The Sauerbrey equation suggests that a QCM device exhibits a linear mass-frequency response when a micro-mass is deposited on its surface. In this study, we present a design strategy for a QCM humidity sensor based on a small-size, high-frequency QCM transducer. A minimal mass (1 μg) of graphene oxide serves as the moisture-sensitive material and is deposited on a 16-MHz QCM device enclosed in a 5032 package, resulting in the fabrication of a QCM humidity sensor. The sensor demonstrates both high sensitivity (82.40 Hz/%RH) and high linearity (adjusted R-square: 0.9892) across a relative humidity range of 11% to 97%. Furthermore, the sensor exhibits low humidity hysteresis (2.5% RH), excellent stability, and repeatability. The methodology proposed in this paper is anticipated to contribute to the development of high-performance QCM humidity sensors.
3 February 2026 in Sensors and Actuators B: Chemical
29 April 2025 in IEEE Sensors Journal
The accurate detection of water content in ethanol is crucial for various industrial processes, such as fuel production and chemical manufacturing. However, existing methods face challenges in terms of sensitivity, stability, and repeatability. This paper presents a new method for detecting the water content in ethanol based on a resonant sensor with a quartz crystal (QC) in series with a interdigital electrode (IDE), called QC-IDE circuit. Theoretical analysis indicates that variations in the equivalent capacitance and resistance of the IDE can influence the response frequency of the QC-IDE circuit. The QC-IDE circuit features two key frequency modulation ranges: one occurs when the IDE resistance Rs > 50 kΩ and the capacitance Cs < 50 pF, the other occurs when the resistance 1 kΩ < Rs < 10 kΩ and the capacitance Cs < 20 pF. The QC-IDE resonator sensor was prepared by adjusting the characterization parameters of IDE , such as electrode spacing and linewidth, and the water content in ethanol was tested in the range of 0% to 100% volume (vol.). Through comprehensive evaluation, the optimal electrode parameter configuration for the QC-IDE circuit was determined. Experimental results demonstrate that the developed sensor achieved a response sensitivity of up to 29.36 Hz/(% vol.) and exhibited good linearity of low water content , stability, and repeatability. These findings suggest that the proposed QC-IDE sensor holds significant potential for applications in ethanol water content detection.
24 November 2025 in IEEE Transactions on Instrumentation and Measurement
Quartz crystal microbalance (QCM) sensors have garnered significant interest in humidity sensor filed due to the excellent advantages of nanogram-level theoretical mass resolution and digital frequency output, etc. However, a key limitation is the substantial energy dissipation in high humidity detection, which results in a low quality-factor (Q-factor), thereby restricting sensitivity and measurement accuracy. To address this issue, we developed a high-Q humidity sensor utilizing a liquid damping isolation strategy. In this design, the graphene oxide (GO) humidity-sensitive layer is supported and isolated by hydrophobic SiO₂ spheres, forming a SiO₂/GO bilayer structure. Experimental results demonstrate that the SiO₂/GO bilayer QCM humidity sensor achieves a high Q value of 66,084 at 97% RH, which is three times greater than that of the pure GO QCM sensor and surpasses previously reported values, demonstrating the excellent stability and the effectiveness of the proposed liquid damping isolation strategy for fabricating a high Q-factor QCM humidity sensor. In addition, the SiO2/GO bilayer structure QCM humidity sensor suggested an ultrafast recovery time (<1 s), good short-term and long-term stability. Based on the outstanding high humidity resistance, the sensor was applied for stable human breath monitoring. This work not only provides a novel idea and valuable reference for high performance QCM sensor fabrication, but also provides a reliable way for human health monitoring based on QCM humidity sensors.