10 October 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The grid voltage feed-forward can improve the dynamic performance of repetitive controller (RC), but it will seriously weaken the stability under non-ideal grid conditions. This paper focuses on the stability and dynamic characteristics of grid-tied inverter with RC and grid voltage feed-forward. The internal model filter of RC uses an infinite impulse response (IIR) filter to improve the steady-state performance. Firstly, an equivalent digital control model with RC and feed-forward is established, the parameters of RC are designed, and the system’s stability is analyzed based on the small gain theorem. Then, it is verified that the stability of RC in the presence of grid impedance can be weakened by the feed-forward term, thus a better feed-forward scheme is required. In addition, the solution for weak grid condition is proposed, and different feed-forward algorithms are compared from various perspectives, which is concluded that the improved proportional and first-order differential feed-forward scheme has a better performance. Finally, the validity of the controller is verified by the experimental prototype of a single-phase LCL-type grid-tied inverter.
21 December 2020 in IEEE Transactions on Power Electronics
In this article, the stability robustness of repetitive control (RC) in the grid-tied inverter is discussed. Due to the limited control band, high-frequency characteristics of the control plant are seriously affected by the modeling and parameter uncertainties, which can lead to RC controller instability. Then, an infinite impulse response (IIR) low-pass filter is applied inside the internal model of RC to improve the stability robustness. To alleviate the effects of the RC gain reduction induced by the phase lag of the IIR filter, an approximated simple computational method of the phase compensation is proposed. The situation of the gain attenuation and frequency deviation of RC caused by the IIR filter is analyzed, and a method that modifies the phase compensator in real time for the IIR filter is applied to resist the grid frequency variation. Parameter design is provided in details, and comparison experiments are performed in different uncertainty situations to demonstrate the effectiveness of the proposed approach.
5 May 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this article, multibandwidth repetitive control (RC) is developed and applied to a grid-tied inverter to resist grid frequency variation. In the proposed RC, each of the resonant bandwidth is set individually by the gain of the internal model filter. A design procedure for the internal model filter is proposed, which splits the filter into several zero-phase finite impulse response (FIR) filters for reducing the design difficulties. The control structure and stability analysis show that the gain of the multibandwidth RC is increased. An example design procedure for the multibandwidth RC is presented in detail. Comparison experiments with different RCs are performed under deviated grid frequencies, and the results demonstrate the effectiveness of the proposed multibandwidth RC scheme.
14 October 2022 in IEEE Transactions on Power Electronics
The uncertainty and disturbance estimator (UDE) with a time delay filter has been widely used for inverter systems due to its satisfactory harmonic rejection performance. However, the control performance may be affected when the grid frequency fluctuates. In this article, a modified UDE (FUDE) is proposed to improve the grid frequency fluctuation adaptability of the $LCL$ grid-tied inverter systems, which contains a compound filter consisting of time delay, zero-phase low-pass, and high-pass filters. Compared with the traditional time delay UDE, it can offer a wider notch bandwidth at the selected frequencies. A dual-loop controller is built in the separate-structure-type UDE-based controller, containing an outer loop PR controller and an inner loop FUDE. The sufficient conditions for the system stability are obtained by the small-gain theorem. The comparison experiments of the dual-loop controller with the proposed FUDE and the conventional time delay zero-phase low-pass UDE are performed on a 2-kW experimental platform, and the results demonstrate the effectiveness of the proposed FUDE.
20 August 2025 in International Journal of Electrical Power & Energy Systems