Jan Odstrcilik

Jan Odstrcilik

Auto-generated profile, based on publicly available information

Jan Odstrcilik

Brno University of Technology

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in IET Image Processing
Verified
Journal Article
Open access
PDF file
JOJan Odstrcilik
Jan Odstrcilik
RKRadim Kolář
Radim Kolář
ABAttila Budai
Attila Budai
JHJoachim Hornegger
Joachim Hornegger
JJJiri Jan
Jiri Jan
EAElli Angelopoulou
Elli Angelopoulou
Automatic assessment of retinal vessels plays an important role in the diagnosis of various eye, as well as systemic diseases. A public screening is highly desirable for prompt and effective treatment, since such diseases need to be diagnosed at an early stage. Automated and accurate segmentation of the retinal blood vessel tree is one of the challenging tasks in the computer‐aided analysis of fundus images today. We improve the concept of matched filtering, and propose a novel and accurate method for segmenting retinal vessels. Our goal is to be able to segment blood vessels with varying vessel diameters in high‐resolution colour fundus images. All recent authors compare their vessel segmentation results to each other using only low‐resolution retinal image databases. Consequently, we provide a new publicly available high‐resolution fundus image database of healthy and pathological retinas. Our performance evaluation shows that the proposed blood vessel segmentation approach is at least comparable with recent state‐of‐the‐art methods. It outperforms most of them with an accuracy of 95% evaluated on the new database.

1 June 2013
Verified
Conference Paper
Closed access
TKThomas Kohler
Thomas Kohler
ABAttila Budai
Attila Budai
MKMartin F. Kraus
Martin F. Kraus
JOJan Odstrcilik
Jan Odstrcilik
GMGeorg Michelson
Georg Michelson
JHJoachim Hornegger
Joachim Hornegger
Fundus imaging is the most commonly used modality to collect information about the human eye background. Objective and quantitative assessment of quality for the acquired images is essential for manual, computer-aided and fully automatic diagnosis. In this paper, we present a no-reference quality metric to quantify image noise and blur and its application to fundus image quality assessment. The proposed metric takes the vessel tree visible on the retina as guidance to determine an image quality score. In our experiments, the performance of this approach is demonstrated by correlation analysis with the established full-reference metrics peak-signal-to-noise ratio (PSNR) and structural similarity (SSIM). We found a Spearman rank correlation for PSNR and SSIM of 0.89 and 0.91. For real data, our metric correlates reasonable to a human observer, indicating high agreement to human visual perception.

1 May 2013 in The Imaging Science Journal
Verified
Journal Article
Closed access
RKRadim Kolář
Radim Kolář
VHV Harabis
V Harabis
JOJ Odstrcilik
J Odstrcilik

1 September 2014 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Open access
JOJan Odstrcilik
Jan Odstrcilik
RKRadim Kolář
Radim Kolář
RTRalf-Peter Tornow
Ralf-Peter Tornow
JJJiri Jan
Jiri Jan
ABAttila Budai
Attila Budai
MRMarina Ronzhina
Marina Ronzhina
Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning.

1 September 2012 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
JJJ. Jan
J. Jan
JOJ. Odstrcilik
J. Odstrcilik
JGJ. Gazarek
J. Gazarek
RKRadim Kolář
Radim Kolář

1 January 2009
Verified
Book Chapter
Closed access
PDF file
JOJ. Odstrčilík
J. Odstrčilík
JJJ. Jan
J. Jan
JGJ. Gazárek
J. Gazárek
RKRadim Kolář
Radim Kolář