Automatic assessment of retinal vessels plays an important role in the diagnosis of various eye, as well as systemic diseases. A public screening is highly desirable for prompt and effective treatment, since such diseases need to be diagnosed at an early stage. Automated and accurate segmentation of the retinal blood vessel tree is one of the challenging tasks in the computer‐aided analysis of fundus images today. We improve the concept of matched filtering, and propose a novel and accurate method for segmenting retinal vessels. Our goal is to be able to segment blood vessels with varying vessel diameters in high‐resolution colour fundus images. All recent authors compare their vessel segmentation results to each other using only low‐resolution retinal image databases. Consequently, we provide a new publicly available high‐resolution fundus image database of healthy and pathological retinas. Our performance evaluation shows that the proposed blood vessel segmentation approach is at least comparable with recent state‐of‐the‐art methods. It outperforms most of them with an accuracy of 95% evaluated on the new database.
Because of its non-destructive nature, label-free imaging is an important strategy for studying biological processes. However, routine microscopic techniques like phase contrast or DIC suffer from shadow-cast artifacts making automatic segmentation challenging. The aim of this study was to compare the segmentation efficacy of published steps of segmentation work-flow (image reconstruction, foreground segmentation, cell detection (seed-point extraction) and cell (instance) segmentation) on a dataset of the same cells from multiple contrast microscopic modalities. We built a collection of routines aimed at image segmentation of viable adherent cells grown on the culture dish acquired by phase contrast, differential interference contrast, Hoffman modulation contrast and quantitative phase imaging, and we performed a comprehensive comparison of available segmentation methods applicable for label-free data. We demonstrated that it is crucial to perform the image reconstruction step, enabling the use of segmentation methods originally not applicable on label-free images. Further we compared foreground segmentation methods (thresholding, feature-extraction, level-set, graph-cut, learning-based), seed-point extraction methods (Laplacian of Gaussians, radial symmetry and distance transform, iterative radial voting, maximally stable extremal region and learning-based) and single cell segmentation methods. We validated suitable set of methods for each microscopy modality and published them online. We demonstrate that image reconstruction step allows the use of segmentation methods not originally intended for label-free imaging. In addition to the comprehensive comparison of methods, raw and reconstructed annotated data and Matlab codes are provided.
10 March 2020 in IEEE Transactions on Intelligent Transportation Systems
Driver fatigue and stress significantly contribute to higher number of car accidents worldwide. Although, different detection approaches have been already commercialized and used by car producers (and third party companies), research activities in this field are still needed in order to increase the reliability of these alert systems. Also, in the context of automated driving, the driver mental state assessment will be an important part of cars in future. This paper presents state-of-the-art review of different approaches for driver fatigue and stress detection and evaluation. We describe in details various signals (biological, car and video) and derived features used for these tasks and we discuss their relevance and advantages. In order to make this review complete, we also describe different datasets, acquisition systems and experiment scenarios.
Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning.
24 January 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
A new signal model and processing method for quantitative ultrasound perfusion analysis is presented, called bolus-and-burst. The method has the potential to provide absolute values of blood flow, blood volume, and mean transit time. Furthermore, it provides an estimate of the local arterial input function which characterizes the arterial tree, allowing accurate estimation of the bolus arrival time. The method combines two approaches to ultrasound perfusion analysis: bolus-tracking and burst-replenishment. A pharmacokinetic model based on the concept of arterial input functions and tissue residue functions is used to model both the bolus and replenishment parts of the recording. The pharmacokinetic model is fitted to the data using blind deconvolution. A preliminary assessment of the new perfusion-analysis method is presented on clinical recordings.