Yingying Zhang

Yingying Zhang

Auto-generated profile, based on publicly available information

Yingying Zhang

Nursing Department, Nanmen Community Health Center, Danan Street, Lucheng District, Wenzhou, Zhejiang Province, 325000, PR China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in International Journal of Surgery
Verified
Journal Article
Closed access
LXLinzhen Xie
Linzhen Xie
CCChunhui Chen
Chunhui Chen
YZYingying Zhang
Yingying Zhang
WZWenhao Zheng
Wenhao Zheng
HCHua Chen
Hua Chen
LCLeyi Cai
Leyi Cai
The objective of this meta-analysis was to assess the influence of three dimensional printing technology on the open reduction and internal fixation (ORIF) of tibial plateau fractures from current randomized controlled trials and prospective comparative studies. The electronic literature database of Pubmed, Embase, and Cochrane library were searched in January 2018. The data operation time, intraoperative blood loss, follow-up knee function (Rasmussen score, HSS) and complications (including infection, screw loosening, knee stiffness, knee instability, posttraumatic osteoarthritis, VTE) were extracted. Stata 12.0 software was used for our meta-analysis. 11 RCTs and 6 prospective comparative studies met our inclusion criteria with 358 tibial plateau fractures patients in the 3D group and 378 patients in the routine ORIF group. The meta-analysis showed that there were significant differences in operation time, intraoperative blood loss and bony union time between the 3D group and conventional group. As for the complications and follow-up function recovery evaluated by the excellent and good rate based on HSS and Rasmussen score, no significant differences were found. The 3D group showed shorter operation time, less intraoperative blood loss and faster union time for patients with tibial plateau fractures. Therefore, compared with conventional ORIF, ORIF assisted by three-dimensional printing technology should be a more appropriate treatment of tibial plateau fractures. Further large-sample randomized controlled trials are needed in the future to confirm the superiority of three-dimensional printing assisted ORIF.

1 January 2020 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
LCLeyi Cai
Leyi Cai
YZYingying Zhang
Yingying Zhang
WZWenhao Zheng
Wenhao Zheng
JWJianshun Wang
Jianshun Wang
XGXiaoshan Guo
Xiaoshan Guo
JWJiqi Wang
Jiqi Wang
Day type II crescent fracture-dislocation is a subtype of pelvic lateral compression injury. At present, there is still a controversy on the operative approach and fixation technique. We have put forward closed reduction and percutaneous crossed screws fixation for treating type-II crescent fracture-dislocation. Finite element analysis is used to compare the biomechanical properties between percutaneous crossed screws and other internal fixations. A three-dimensional finite element model of Day type-II crescent fracture-dislocation was simulated using 5 implants, including double anterior plates (Model A), one posterior plate and one iliac screw (Model B), one sacroiliac joint screw (Model C), crossed one iliac screw and one sacroiliac joint screw (Model D), and crossed two iliac screws and one sacroiliac joint screw (Model E). 600-N stress was applied to S1 vertebral end-plate. To evaluate the biomechanical properties, the stress distribution and displacement distribution of the pelvis, stress distribution of the crescent fragment and stress distribution of plate and cannulated screw were recorded and analyzed. Under the loading of 600N, the maximum pelvic displacements in the finite element model were compared as follows: model E (0.070 ​mm), model D (0.071 ​mm), model A (0.080 ​mm), model C (0.096 ​mm), and model B (0.112 ​mm). The maximum displacements of crescent fragment were compared as follows: model E (0.018 ​mm), model B (0.022 ​mm), model D (0.023 ​mm), model A (0.030 ​mm), and model C (0.043 ​mm). The maximum stress of all implants were compared as follows: model D (90.01 ​Mpa), model E (81.60 ​Mpa), model C (69.07 ​Mpa), model A (56.51 ​Mpa), model B (18.29 ​Mpa). Model E and model D could provide better mechanical support for whole pelvic. With sufficient biomechanical stability and minimally invasive advantage, percutaneous crossed screw fixation is a recommended treatment for Day Type-II Crescent Fracture-dislocation. It is recommended to fix crescent fracture fragment and sacroiliac joint simultaneously during the operation. If it is difficult to fix the both position, the sacroiliac joint is preferentially fixed. There is a controversy on the operative approach and fixation technique of Day type-II crescent fracture-dislocation. This article proves that percutaneous crossed screw fixation is a recommended treatment for Day type-II crescent fracture-dislocation by finite element analysis.

4 October 2024 in Injury
Verified
Journal Article
Closed access
FZFeiya Zhou
Feiya Zhou
XZXian Zhang
Xian Zhang
YZYingying Zhang
Yingying Zhang
GXGuangheng Xiang
Guangheng Xiang
PLPeng Luo
Peng Luo
LCLeyi Cai
Leyi Cai

1 June 2026 in Injury
Verified
Journal Article
Closed access
FZFeiya Zhou
Feiya Zhou
HLHuachen Liu
Huachen Liu
YZYingying Zhang
Yingying Zhang
JWJinwu Wang
Jinwu Wang
HCHua Chen
Hua Chen
LCLeyi Cai
Leyi Cai