Fei Yang

Fei Yang

Auto-generated profile, based on publicly available information

Fei Yang

State Key Laboratory of Electrical Insulation and Power Equipment, School of Electric Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YWYifei Wu
Yifei Wu
YXYu Xiao
Yu Xiao
YWYi Wu
Yi Wu
MRMingzhe Rong
Mingzhe Rong
FYFei Yang
Fei Yang
The hybrid dc circuit breaker (HDCCB) is one of the most promising solutions for the dc interruption. But the power electronics-based load commutation switch (LCS) in the main current path causes the high on-state loss and cost, which inhibits the application of the HDCCB. In this paper, a novel hybrid dc circuit breaker is proposed, in which the vacuum interrupter with the external transverse magnetic field (ETMF) is designed to improve the arc voltage and thus enhance the current commutation to power electronics. The ETMF-based vacuum interrupter achieves the fast current commutation instead of the LCS, which realizes the low on-state loss and cost while preserving the short commutation and interruption time. The arc voltage characteristic with ETMF is analyzed, and the influence of the different factors on the commutation time and di/dt before current zero are investigated in detail. Based on the calculation results, a 10 kV dc breaker prototype based on the proposed topology is developed with the breaking current of 15.5 kA. Finally, the application of the proposed scheme in HVdc grids is discussed.

24 June 2020 in IEEE Access
Verified
Journal Article
Open access
Hao SunHao Sun
Hao Sun
LLLuqi Liang
Luqi Liang
CWChunlin Wang
Chunlin Wang
YWYi Wu
Yi Wu
FYFei Yang
Fei Yang
MRMingzhe Rong
Mingzhe Rong
Finding substitutes for sulfur hexafluoride (SF 6 ), a gas with extremely high global warming potential, has been a persistent effort for years in the field of high voltage power equipment, which focuses on the evaluation of the electrical strength and boiling temperature for the practical purpose. Following up the previous proposed linear regression models, this work introduces machine learning algorithms including artificial neural network (ANN) and random forest (RF) as the potential approaches to predict the electrical strength and boiling temperature. Based on a series of descriptors derived from the molecular structure of 74 molecules, the performance of three different methods: multiple linear regression, artificial neural network and random forest are compared and assessed in terms of the sensitivity to the sample size, prediction accuracy and stability, and the interpretability of predictors. Considering the available data are limited, random forest shows superior performance with higher robustness and efficiency. The same approaches were applied to the boiling temperature and random forest produced better results as well. Besides, the variable importance ranked by RF improves understanding of the correlation between the molecular properties and electrical strength. It provides important insights to analyze the properties of the SF 6 substitutes during the design and synthesis of the new eco-friendly gases in power equipment.

8 January 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XHXiangyu Han
Xiangyu Han
FYFei Yang
Fei Yang
HCHongbin Chen
Hongbin Chen
YBYuchen Bai
Yuchen Bai
ZGZhanbu Gu
Zhanbu Gu
MRMingzhe Rong
Mingzhe Rong
The rated current and short-circuit current of the large-capacity generator circuit breaker (GCB) far exceed the limit of a single vacuum circuit breaker (VCB). In this paper, a large-capacity GCB scheme based on multiple VCBs in parallel was proposed, focusing on the parallel current-sharing characteristics. Firstly, the current-sharing path and current transfer path were clarified, and a complete and specific circuit model was established. Secondly, the product variability of the vacuum interrupter (VI) and the action dispersion of the operating mechanism would cause the “current unbalance” problem. The influence rule of impedance matching, arc voltage, arcing synchronization, and other factors on the current-sharing characteristics was studied in detail, and the method that can effectively improve the static and dynamic current-sharing was proposed. In addition, the phase-to-phase electromagnetic field would cause the current of each VI in single-phase GCB to have an obvious phase difference, which greatly reduced the current-sharing effect. The electromagnetic shielding shell (ESS) installed on the GCB could effectively shield the external electromagnetic field and significantly improve the current-sharing effect. The improved ESS significantly reduced phase-to-phase magnetic leakage and avoided magnetic field pollution. Finally, the current-sharing experiment of the prototype proved that the proposed scheme could achieve a better parallel current-sharing effect, which may initially solve the problem of the insufficient current carrying capacity of the VCB.

1 August 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
QYQiang Yi
Qiang Yi
FYFei Yang
Fei Yang
YWYifei Wu
Yifei Wu
YWYi Wu
Yi Wu
CGChong Gao
Chong Gao
MRMingzhe Rong
Mingzhe Rong

24 September 2015 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
YWYi Wu
Yi Wu
ZCZhexin Chen
Zhexin Chen
FYFei Yang
Fei Yang
YCYann Cressault
Yann Cressault
AMAnthony B. Murphy
Anthony B. Murphy
HSHao Sun
Hao Sun
SF6 and Cu are widely adopted in electrical equipment as a dielectric medium and for conductive components, respectively. SF6–Cu plasmas are frequently formed, particularly in high-voltage circuit breaker arcs and fault current arcs, due to erosion of the Cu components. In this paper, calculated values of the thermodynamic and transport properties of plasmas in SF6–Cu mixtures are presented for both thermal equilibrium and non-equilibrium conditions. The composition is determined by the two-temperature Saha equation and Guldberg–Waage equation in the form derived by van de Sanden. The composition and the thermodynamic properties are evaluated through a classical statistical mechanics approach. For the transport coefficients, the simplified Chapman–Enskog method developed by Devoto, which decouples the electrons and heavy species, has been applied using the most recent collision integrals. The thermodynamic and transport properties are calculated for different electron temperatures (300–40 000 K), ratios of electron to heavy-species temperature (1–10), pressures (0.1–10 atm) and copper molar proportions (0–50%). It is found that deviations from thermal equilibrium strongly affect the thermodynamic and transport properties of the SF6–Cu plasmas. Further, the presence of copper has different effects on some of the properties for plasmas in and out of thermal equilibrium. The main reason for these changes is that dissociation reactions are delayed for non-thermal equilibrium plasmas, which in turn influences the ionization reactions that occur.

13 October 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
QYQiang Yi
Qiang Yi
YWYifei Wu
Yifei Wu
ZZZhihui Zhang
Zhihui Zhang
FYFei Yang
Fei Yang
YWYi Wu
Yi Wu
MRMingzhe Rong
Mingzhe Rong
DC circuit breaker plays an important role in the reliability of HVdc system, but the large number of expensive press-pack insulated-gate bipolar transistors (IGBTs) is used at present, which is a serious impediment to HVdc development. Thus, the low-price integrated gate commutated thyristor (IGCT) becomes a promising alternative device. This letter presents a low-cost HVdc circuit breaker with high current breaking capability based on IGCTs. The topology and principle of the proposed HVdc circuit breaker are introduced at first. Then, the parameter design is analyzed. A scaled-down test successfully demonstrates the high current breaking capability of 15 kA. In the end, the cost comparison shows that this scheme can achieve 61.8% cost reduction of the commutation branch.