1 January 2022 in SSRN Electronic Journal
Flexible capacitive pressure sensors with a simple structure and low power consumption are attracting attention owing to their wide range of applications in wearable electronic devices. However, it is difficult to manufacture pressure sensors with high sensitivity, wide detection range, and low detection limits. We developed a highly sensitive and flexible capacitive pressure sensor based on the porous Ecoflex, which has an aligned airgap structure and can be manufactured by a simply using a mold and micro-needle. The existence of precisely aligned airgap structures significantly improved the sensor sensitivity compared to other dielectric structures without airgaps. The proposed capacitive pressure sensor with an alignment airgap structure supports a wide range of working pressures (1 Pa – 100 kPa), quick response time (≈100 ms), high operational stability, and low-pressure detection limit (20 Pa). Moreover, we also studied the application of pulse wave monitoring in wearable sensors, exhibiting excellent performance in wearable devices that detect pulse waves before and after exercise. The proposed pressure sensor is applicable in electronic skin and wearable medical assistive devices owing to its excellent functional features.
7 January 2026 in Additive Manufacturing
28 August 2026 in SSRN Electronic Journal
Biogas dry reforming of methane (DRM) is a promising pathway for the simultaneous CO2 utilization and renewable hydrogen production; however, its practical application is limited by severe catalyst deactivation attributed to carbon deposition and the high heat demand of the endothermic reaction. In this study, a membrane-based CH4/CO2 composition control strategy is proposed for regulating the reforming environment, thereby enabling simultaneous coking suppression and energy self-sufficiency in DRM. A multicomponent gas-separation model for the membrane is developed and validated using pilot-scale operating data to implement this strategy, which exhibits excellent agreement with deviations below 1%. Process simulations demonstrate that the membrane-enabled control maintains a CO2/CH4 ratio above unity, which is favorable for coking suppression while producing high-purity biomethane (>90%). Unlike conventional approaches that maximize methane recovery, a portion of the separated biomethane is utilized as an internal fuel to supply the heat required for DRM, and the resulting CO2-rich flue gas is recycled to the reforming feed. This integrated strategy enables the simultaneous control of the feed composition and heat supply without external fuel input. The DRM performance over the Ni/Al2O3 catalyst is evaluated experimentally and through kinetic modeling. Methane conversion exceeds 99%, whereas the hydrogen yield ranges from ~60–65% under CO2-rich conditions. Increasing the CO2/CH4 ratio significantly reduces the carbon deposition from 5.3 wt% to negligible levels. The developed reaction–deactivation kinetic model accurately reproduces the experimental trends within 4% deviation. Consequently, the proposed integrated process provides a scalable pathway for thermally self-sustaining hydrogen production.
23 October 2026 in Sensors and Actuators A: Physical
16 April 2026 in Smart Materials and Structures
Recent advances in additive manufacturing, particularly 3D printing, have expanded its use in wearable sensor fabrication. Flexible capacitive pressure sensors can achieve enhanced sensitivity by introducing microstructured dielectric layers, and 3D printing is widely adopted because it enables precise fabrication of complex three-dimensional dielectric architectures that are difficult to realize using conventional processes. However, the inherently low dielectric constant of typical 3D-printable resins remains a key factor limiting sensor performance. In this study, we propose an SLA-based 3D-printed flexible capacitive pressure sensor that integrates both structural and material strategies. The dielectric layer was designed as a “O”-shaped arch composite structure combining semicircular arches and inverted arches. To increase the dielectric permittivity, multi-walled carbon nanotubes (MWCNTs) were incorporated into an Elastic 50A resin within a range of 0–0.5 wt% to form a composite resin. As a result, the dielectric constant increased with increasing MWCNT content, reaching its maximum at 0.5 wt% measured at 1 MHz. The fabricated sensor was capable of detecting ultralow pressures of 15–40 Pa, exhibited a fast response time of ~300 ms and stable output under over 3000 loading cycles at 20 kPa. Finally, wearable demonstrations, including biceps and calf muscle activity as well as respiration monitoring, confirmed its applicability to wearable application. This approach extends dielectric design freedom through composite-material-based 3D printing and mitigates intrinsic material limitations, thereby contributing to improved sensitivity in flexible capacitive pressure sensors