1 October 2020 in TrAC Trends in Analytical Chemistry
1 April 2019 in Sensors and Actuators B: Chemical
20 June 2020 in Electrophoresis
26 May 2016 in The Analyst
To date, the forensic community regards solid phase extraction (SPE) as the most effective methodology for the purification of DNA for use in short tandem repeat (STR) polymerase chain reaction (PCR) amplification. While a dominant methodology, SPE protocols generally necessitate the use of PCR inhibitors (guanidine, IPA) and, in addition, can demand timescales of up to 30 min due to the necessary load, wash and elution steps. The recent discovery and characterization of the EA1 protease has allowed the user to enzymatically extract (not purify) DNA, dramatically simplifying the task of producing a PCR-ready template. Despite this, this procedure has yet to make a significant impact on microfluidic technologies. Here, we describe a microfluidic device that implements the EA1 enzyme for DNA extraction by incorporating it into a hybrid microdevice comprising laminated polyester (Pe) and PMMA layers. The PMMA layer provides a macro-to-micro interface for introducing the biological sample into the microfluidic architecture, whilst also possessing the necessary dimensions to function as the swab acceptor. Pre-loaded reagents are then introduced to the swab chamber centrifugally, initiating DNA extraction at 75 °C. The extraction of DNA occurs in timescales of less than 3 min and any external hardware associated with the transportation of reagents by pneumatic pumping is eliminated. Finally, multiplexing is demonstrated with a circular device containing eight separate chambers for the simultaneous processing of eight buccal swab samples. The studies here provide DNA concentrations up to 10 ng μL−1 with a 100% success rate in less than 3 minutes. The STR profiles generated using these extracted samples demonstrate that the DNA is of PCR forensic-quality and adequate for human identification.
25 October 2017 in Lab on a Chip
Colorimetry with microfluidic devices has been proven to be an advantageous method for in situ analyses where limited resources and rapid response for untrained users are desired. Image analysis using a small camera or cell phone can be easily incorporated for an objective readout, eliminating variations from normal differences in color perception and environmental factors during analysis. The image analysis using the parameter hue, for example, has been utilized as a highly effective, objective analysis method that correlates with the psychological way color is perceived. Hue analysis, however, is best used for colorimetric reactions that result in distinct changes from one color to a markedly different color and can be inadequate to distinguish between subtle or monotonal (colorless-to-colored) color changes. We address this with three unique color manipulation (i.e., tinting) techniques that provide greater discrimination with such color changes, thus yielding improved limits of detection for various colorimetric reactions that may have previously been limited. Tinting is invoked through dyeing the reagent substrate, colored printing the device, or colored lighting during image capture, and is shown to effectively shift the background color of the reaction detection area. Hydrogen peroxide, a constituent of peroxide-based explosives, is associated with a monochromatic color change upon reaction, and this is used to demonstrate the effectiveness of the tinting methods in improving the limit of detection from an undetectable color change to 0.1 mg mL−1.
29 June 2021 in Journal of the American Society for Mass Spectrometry