An original monitoring system allowing in situ and continuous quantification of gases dissolved in an aquifer and combining Raman and infrared fiber sensors. The gas baseline was established before an experimental simulation of hydrogen injection.
This paper presents the results of an experiment to simulate a sudden and brief hydrogen leak from a potential deep geological storage site. A 5 m3 volume of groundwater was extracted, saturated with hydrogen, and then reinjected into the aquifer. Saturating the water with hydrogen caused a decrease in the oxidation-reduction potential, the dissolved gas content (especially O2 and CO2), the electrical conductivity, and the concentration of alkaline earth bicarbonate ions and a slight increase in pH. These changes are observed until 20 m downstream of the injection well, while the more distant piezometers (from 30 to 60 m) are not significantly affected. During this experiment, no indicators of the development of chemical or biochemical reactions are observed, because of the rapid transfer of the dissolved hydrogen plume through the aquifer and its significant dilution beyond 10 m downstream of the injection well. Here, hydrogen behaved as a conservative element, reacting very slightly or not at all. However, this experiment demonstrates the existence of direct and indirect impacts of the presence of hydrogen in an aquifer. This experiment also highlights the need to adapt the monitoring of future underground hydrogen storage sites.
Massive underground storage of hydrogen could be a way that excess energy is produced in the future, provided that the risks of leakage of this highly flammable gas are managed. The ROSTOCK-H research project plans to simulate a sudden hydrogen leak into an aquifer and to design suitable monitoring, by injecting dissolved hydrogen in the saturated zone of an experimental site. Prior to this, an injection test of tracers and helium-saturated water was carried out to validate the future protocol related to hydrogen. Helium exhibits a comparable physical behavior but is a non-flammable gas which is preferable for a protocol optimization test. The main questions covered the gas saturation conditions of the water, the injection protocol of 5 m3 of gas saturated water, and the monitoring protocol. Due to the low solubility of both helium and hydrogen, it appears that plume dilution will be more important further than 20 m downstream of the injection well and that monitoring must be done close to the well. In the piezometer located 5 m downstream the injection well, the plume peak is intended to arrive about 1 h after injection with a concentration around 1.5 mg·L−1. Taking these results into account should make it possible to complete the next injection of hydrogen.
1 August 2021 in Geochemistry: Exploration, Environment, Analysis
Since the development of portable X-ray fluorescence (pXRF) spectrometers, few studies have been conducted on the influence of spectral interferences between chemical elements. This study aims to improve the management of these interferences to obtain more reliable geochemical analyses. We specifically investigate Ca-related interferences on Sc analysis for the case of Ni-rich laterite samples using the Niton XL3t GOLDD + pXRF analyser. Three quantification methods were tested on 59 pelletized samples using the ‘Soil’ mode. The first, named ‘Manufacturer’, represents the elemental quantification directly provided by the device based on regions of interest and multilinear corrections of spectral interferences configured during the spectrometer design. The second, the ‘20 Cu’ method, is based on spectral fitting using the PyMCA software. The third, the ‘18 Fe’ method, combines spectral fitting with modified experimental conditions. For each, a quantification methodology was developed, establishing (i) Ca and Sc calibration lines and (ii) Ca/Sc threshold values delimiting fields of ‘reliable’, ‘to be confirmed’ and ‘unreliable’ measurements. The ‘20 Cu’ and ‘18 Fe’ methods greatly extend the ‘reliable measurements’ field concerning the Ca/Sc ratio compared to the ‘Manufacturer’ method. The ‘18 Fe’ method was also found to provide the most negligible measurement dispersion. Supplementary material: Figures A–F and Tables A and B are available at https://doi.org/10.6084/m9.figshare.c.5511838
To manage potential risks due to H 2 leaks into the near-surface geosphere from H 2 underground storages (e.g. salt caverns, aquifer), reliable monitoring methods along with a precise knowledge of the geochemical environmental impacts are necessary. Thus, the evolution of some prominent parameters in soil and aquifers can be determined: gas concentrations, redox potential, ionic balance and trace elements. As part of the ROSTOCK’H project, Ineris simulated H 2 leakage by injection of dissolved H 2 into a shallow aquifer (~20 m deep) in an experimental site within the Paris basin. This experiment aimed to testing advanced monitoring techniques and studying hydrogeochemical impacts at shallow depths. The aquifer water has calcium-bicarbonate facies and a neutral pH. Eight piezometers were aligned over 80 m according to the aquifer main flow (west-east). Hydrogeochemical monitoring devices were set up. One of the piezometers was equipped with a completion connected to a Raman probe and a specific Mid-IR cell for continuous measurement of aqueous gases. At the experiment outset, 5 m 3 of water were extracted from the aquifer to be saturated with H 2 under atmospheric conditions, before being reinjected through the injection well. About 100 L STP of dissolved H 2 (concentration of 1,8 mg/L) was injected in the aquifer. The H 2 injection was preceded by the injection of underground water containing tracers (He (aq) , uranine and LiCl) in order to warn the H 2 plume arrival in the piezometers located downstream of the injection well. The concentrations of aqueous gases (He, H 2 , N 2 , O 2 , CO 2 , H 2 S and CH 4 ) were measured in a control piezometer (20 m upstream) and in six piezometers up to 60 m downstream. Thus, the maximum H 2 contents were detected up to 20 m downstream of the injection well: 0.6 mg/L at 5 m, 0.17 mg/L at 7 m then 1.8 µg/L of H 2 at 10 and 20 m during the first week. Following the H 2(aq) addition, the aquifer physico-chemistry has been modified: low increase in pH, high decrease in redox potential and O 2(aq) . These results confirm the feasibility of detecting and monitoring H 2 in shallow aquifers in very low concentration conditions and highlight the potential impacts. This is of first importance for establishing the surveillance and security aspects related to with H 2 storage.
Storing dihydrogen (H2) underground in salt caverns is seen as a vector of the energy transition. To ensure that risks related to leakage are managed, monitoring methods are needed to detect any H2 unintended migration. Because the shallow subsurface will act as an ultimate barrier before the gas reaches surface and dwellings, there is also a need to increase knowledge on geochemical impacts of a H2 leakage on shallow environments.Geochemical monitoring methods exist and make it possible to detect H2 directly (H2 concentrations in dissolved and gaseous phases) or indirectly (e.g. CO2, O2, N2 concentrations in dissolved and gaseous phases, ionic balance and some trace elements, redox potential).Within the framework of the Rostock'H project funded by the French R&D program GEODENERGIES, a leakage in the shallow subsurface was simulated by injecting water with dissolved H2 into the aquifer (~20 m deep). Injection was done in November 2019 on a dedicated experimental site and aimed at testing monitoring techniques but also at studying geochemical impacts at very shallow depths. The site is located in the Paris sedimentary basin (Catenoy city). The unconfined aquifer is within the Senonian (Cretaceous) chalk formation. The overlying unsaturated zone includes Bracheux sands (Paleogene) and Quaternary colluvium. The average water table is 12 m deep. The underground water has calcium-bicarbonate facies and a pH close to neutral. Eight piezometers were drilled, aligned over 80 m in the direction of the aquifer main flow (West-East) and slotted between 12 and 25 m deep. Moreover, four dry boreholes were drilled above the piezometric level to monitor the unsaturated zone. Each one was in the close vicinity of a piezometer and slotted between 3 and 11 m deep. The site was equipped with geochemical monitoring tools selected or developed by Ineris and University of Lorraine. For instance, one of the monitoring wells was equipped with a gas completion and connected to a gas RAMAN probe and to a MID IR gas cell with low optical path.For the experiment purpose, 5 m3 of underground water were pumped, saturated with H2 at surface conditions and injected again in the aquifer using one of the piezometers. The H2 injection was preceded by an injection of 1 m3 of underground water saturated with selected chemically inert gas tracer (helium: He) and containing two selected hydrological tracers (uranine and lithium chloride) to anticipate the H2 arrival in the downstream piezometers used as monitoring wells. Dissolved gas concentrations (He, H2, N2, O2, CO2, H2S and CH4) were very frequently monitored in situ in the first 4 downstream piezometers (until 20 m from the input well) during the first week. Consequently, the maximum concentrations of dissolved He and H2 were respectively detected 49 hours and 71 hours after the injection started in the piezometer located 10 m downstream the injection well. Moreover, water samples were collected at several time steps to analyze, in laboratory, ionic balance and trace element concentrations in order to assess the environmental impact of a H2 leakage.