Nhu Q. Nguyen

Nhu Q. Nguyen

Auto-generated profile, based on publicly available information

Nhu Q. Nguyen

Ryerson Univ. (Canada)

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2017 in Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques
Verified
Journal Article
Closed access
PDF file
DGDaipayan Guha
Daipayan Guha
NANaif M. Alotaibi
Naif M. Alotaibi
NNNhu Nguyen
Nhu Nguyen
SGShaurya Gupta
Shaurya Gupta
CMChristopher McFaul
Christopher McFaul
VYVictor Yang
Victor Yang
Augmented reality (AR) superimposes computer-generated virtual objects onto the user’s view of the real world. Among medical disciplines, neurosurgery has long been at the forefront of image-guided surgery, and it continues to push the frontiers of AR technology in the operating room. In this systematic review, we explore the history of AR in neurosurgery and examine the literature on current neurosurgical applications of AR. Significant challenges to surgical AR exist, including compounded sources of registration error, impaired depth perception, visual and tactile temporal asynchrony, and operator inattentional blindness. Nevertheless, the ability to accurately display multiple three-dimensional datasets congruently over the area where they are most useful, coupled with future advances in imaging, registration, display technology, and robotic actuation, portend a promising role for AR in the neurosurgical operating room.

5 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RJRaphael Jakubovic
Raphael Jakubovic
DGDaipayan Guha
Daipayan Guha
SGShaurya Gupta
Shaurya Gupta
MLMichael Lu
Michael Lu
JJJamil Jivraj
Jamil Jivraj
VYVictor Yang
Victor Yang
Intraoperative image-guided surgical navigation for craniospinal procedures has significantly improved accuracy by providing an avenue for the surgeon to visualize underlying internal structures corresponding to the exposed surface anatomy. Despite the obvious benefits of surgical navigation, surgeon adoption remains relatively low due to long setup and registration times, steep learning curves, and workflow disruptions. We introduce an experimental navigation system utilizing optical topographical imaging (OTI) to acquire the 3D surface anatomy of the surgical cavity, enabling visualization of internal structures relative to exposed surface anatomy from registered preoperative images. Our OTI approach includes near instantaneous and accurate optical measurement of >250,000 surface points, computed at >52,000 points-per-second for considerably faster patient registration than commercially available benchmark systems without compromising spatial accuracy. Our experience of 171 human craniospinal surgical procedures, demonstrated significant workflow improvement (41 s vs. 258 s and 794 s, p < 0.05) relative to benchmark navigation systems without compromising surgical accuracy. Our advancements provide the cornerstone for widespread adoption of image guidance technologies for faster and safer surgeries without intraoperative CT or MRI scans. This work represents a major workflow improvement for navigated craniospinal procedures with possible extension to other image-guided applications.

1 February 2020 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
NNNhu Q. Nguyen
Nhu Q. Nguyen
JCJillian Cardinell
Jillian Cardinell
JRJoel M. Ramjist
Joel M. Ramjist
PLPhilips Lai
Philips Lai
YDYuta Dobashi
Yuta Dobashi
VYVictor Yang
Victor Yang

1 February 2020 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
NNNhu Q. Nguyen
Nhu Q. Nguyen
Stefano Maria PriolaStefano Maria Priola
Stefano Maria Priola
JRJoel M. Ramjist
Joel M. Ramjist
DGDaipayan Guha
Daipayan Guha
YDYuta Dobashi
Yuta Dobashi
VYVictor Yang
Victor Yang

3 December 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
CCChaoliang Chen
Chaoliang Chen
WSWeisong Shi
Weisong Shi
RDRyan Deorajh
Ryan Deorajh
NNNhu Nguyen
Nhu Nguyen
JRJoel Ramjist
Joel Ramjist
VYVictor Yang
Victor Yang
In this Letter, we propose a beam-shifting optical coherence tomography scheme for speckle reduction and blood flow rate calculation, where variations of the speckle pattern and Doppler angle were generated by parallel shifting of the sample beam incident on the objective lens. The resultant optical coherent tomography images could then be averaged for speckle noise reduction and simultaneously analyzed for flow rate measurement. The performance of the proposed technique was verified by both phantom and in vivo experiments.

7 February 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
JJJamil Jivraj
Jamil Jivraj
RDRyan Deorajh
Ryan Deorajh
PLPhillips Lai
Phillips Lai
CCChaoliang Chen
Chaoliang Chen
NNNhu Nguyen
Nhu Nguyen
VYVictor Yang
Victor Yang