9 August 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LWLijun Wang
Lijun Wang
ZZZhefeng Zhang
Zhefeng Zhang
JCJieli Chen
Jieli Chen
ZYZe Yang
Ze Yang
JJJing Jiang
Jing Jiang
SJShenli Jia
Shenli Jia
In the vacuum DC circuit breaker based on the artificial current zero, the change of arc luminosity delays the change of current value significantly in the fast current-zero stage. This phenomenon has impacts on the breaking capacity of the DC vacuum circuit breaker. Therefore, it is necessary to study the dynamic characteristics of the arc plasma under the above condition. In this work, a 3D transient magneto-hydro-dynamic model based on the commercial cup-type axial magnetic field (AMF) contact is established to study this phenomenon. The simulation results show that the fast current-zero stage is too short for the plasma to diffuse. The changes of the physical characteristics of the arc plasma lag the change of current value. Moreover, the magnetic field hysteresis caused by the eddy current on the electrode occurs in this stage, resulting in a continuous stronger AMF. It makes the distributions of the plasma uniform, while the diffusion of the arc plasma reduced at low currents, which is detrimental to the post-arc dielectric recovery stage. In addition, in the fast current-zero stage, the AMF near the contact slot is smaller than in other areas. This indicates that the slotting is effective in suppressing eddy currents and avoiding the negative effect of excessive AMF on plasma diffusion at this stage. The simulation results are consistent with the experimental results.

1 March 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
LWLijun Wang
Lijun Wang
JCJieli Chen
Jieli Chen
ZZZhefeng Zhang
Zhefeng Zhang
MLMing Luo
Ming Luo
YXYiduo Xie
Yiduo Xie
HWHongjian Wang
Hongjian Wang
For vacuum circuit breakers, the anode will change to active mode when the current is high enough. The vapor produced by the anode will become another important source of plasma. In this paper, a three-dimensional (3D) magnetohydrodynamic model considering anode vapor and multiple components is developed to study the vacuum circuit breakers with cup-shaped CuCr contact. The characteristics of arc under the actual magnetic field with different anode temperature distribution and different cathode utilization are simulated. Moreover, the ionization and recombination processes between different kinds of components are considered. The simulation results show that the arc current concentrates toward the center. The current value is high between electrodes slots under the actual magnetic field, which significantly affects the arc characteristics. At the same time, higher anode temperatures will produce more neutral atom vapor area (NAVA). Current is concentrated outside NAVA due to the low conductivity of NAVA. As NAVA expands, the constriction of current on the outside is more severe. The simulation results in this paper are consistent with the experimental results.

13 October 2015 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
RJRui Jia
Rui Jia
LXLei Xue
Lei Xue
HLHuagang Liang
Huagang Liang
KGKun Gao
Kun Gao
JLJian Li
Jian Li
ZZZhefeng Zhang
Zhefeng Zhang
Solitary plasmacytoma of the bone, especially of a single rib, is a rare disease. We present the case of a 44-year-old Han Chinese man who was diagnosed with a solitary plasmacytoma of the bone located in the right sixth rib. The patient presented with a 4-year history of continuous pain in the right chest area and moderate fever lasting 7 days. A chest roentgenogram showed a solitary expanding lesion in the right thorax, and chest computed tomography revealed an osteolytic tumor in the chest wall. The patient underwent complete en-bloc resection of the chest wall, including the ribs, muscle, and parietal pleura. Histologically, the resected mass was composed of abundant neoplastic plasma cells, and the diagnosis was confirmed to be a plasmacytoma of rib. The examination of marrow cells showed 9 % normal plasma cells among karyocytes without clonal disease. On postoperative day 14, the patient underwent thoracic radiotherapy with a total dose of 50 Gy. The patient remained asymptomatic during the 6-month follow-up period. Herein, we also review previous reports on solitary plasmacytomas of the rib. In summary, this report provides further insights for the diagnosis and effective treatment of this rare disease.

1 November 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
HWHongda Wang
Hongda Wang
LWLijun Wang
Lijun Wang
QMQiang Ma
Qiang Ma
ZWZhiwei Wang
Zhiwei Wang
ZZZhefeng Zhang
Zhefeng Zhang
WZWenzhe Zhang
Wenzhe Zhang
In this study, to investigate vacuum arc characteristics under different diameter-to-gap distance ratios (D/g), experiments are conducted on axial magnetic field (AMF) contacts with varying D/g. The peak current value ranges from 15 to 35 kA. The experimental results show that the ability of AMF contacts to control the arc decreases with D/g. Furthermore, the 2/3 coil contact can control the arc under long gap distances, whereas the cup-shaped contact cannot effectively control the arc under long gap distances. The arc energy and noisy period duration decrease with increasing D/g. The arc voltage of the 2/3 coil contact at the peak moment is always the lowest compared to the cup-shaped contact and the 1/2 coil contact, and the arc voltage of the 2/3 coil contact at the peak moment has an approximate power function relation with D/g. The simulation results show that the AMF distribution changes from saddle shape to bell shape with decreasing D/g. The 2/3 coil contact is more suitable for high-voltage vacuum interrupters (VIs), while the cup-shaped contact is more suitable for medium-voltage VIs.

1 August 2022 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
HWHongda Wang
Hongda Wang
LWLijun Wang
Lijun Wang
RZRunming Zhang
Runming Zhang
QMQiang Ma
Qiang Ma
CWCong Wang
Cong Wang
ZWZhiwei Wang
Zhiwei Wang
This paper aims to investigate the anode modes of vacuum arc at different opening speeds, especially at a high opening speed that exceeds 3 m/s. The butt contacts made of CuCr30 and CuCr50 with a diameter of 15 mm are used. Experiments are conducted at the current of 3.3, 4.4, 5.5, and 6.3 kA with a frequency of 50 Hz. An electromagnetic repulsion actuator provides the average opening speed from 1.7 to 3 m/s. The experimental results show that the number of droplets splashing into electrodes increases as the arc current increases, while a higher opening speed decreases the droplets. A higher opening speed will reduce the transferred charge before the anode spot type 2, and a higher Cr content increases the transferred charge before the anode spot type 2. Increasing opening speed will decrease the starting time of anode spot type 2, but it increases the gap distance when anode spot type 2 appears. Meanwhile, the increase in Cr content delays the formation of anode spot type 2.

1 June 2023 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
ZZZhefeng Zhang
Zhefeng Zhang
LWLijun Wang
Lijun Wang
JCJieli Chen
Jieli Chen
ZWZhiwei Wang
Zhiwei Wang
JQJilei Que
Jilei Que
To study the physical mechanism of the separation between heavy and light species in the vacuum arc devices with deuteride cathodes, a three-fluid model based on magnetohydrodynamic (MHD) theory is established. In the model, different kinds of species are considered to be different kinds of fluids, and their physical parameters are calculated separately. Moreover, the distribution of arc current is calculated by the generalized Ohm's law, and the ionization and recombination of species are taken into account. In the paper, the two cases where the cathode is Zr or ZrD0.67 are simulated, respectively. The results show that in the case of ZrD0.67 cathode, the separation of light and heavy species is remarkable. Because of D's lighter mass and lower mass-to-charge ratio, the distribution of it is more uniform. In addition, the differences between species also lead to large differences in other physical characteristics, such as ion velocity, ion temperature, and so on. Notably, the desorption and ionization of deuterium lead to a decrease in plasma temperature. The self-generated magnetic field of the arc has an inhibitory effect on the expansion of each species, and it is more obvious for ions with lower mass-to-charge ratio. The simulation results are consistent with the experimental results. The theoretical analysis can provide theoretical guidance for the improvement of vacuum arc devices with composite or gas-saturated cathodes.