3 June 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYuwen Wu
Yuwen Wu
CTCuihua Tian
Cuihua Tian
ZZZhexuan Zhang
Zhexuan Zhang
BCBaichao Chen
Baichao Chen
SLShaojie Liu
Shaojie Liu
YCYaojun Chen
Yaojun Chen
If current transformer (CT) is saturated in operation, it will lead to incorrect current measurements and may cause relay maloperation, which can greatly threaten the safety of power grid. This paper analyzed the basic measuring characteristics of the proposed novel current transformer based on virtual air gap. This method can successfully compensate the distorted secondary current and expand the measuring range. Based on the simplified magnetization curve model, its working state is divided into linear working state, partially saturated working state and saturated state. Furthermore, its basic measuring characteristics are deducted theoretically. The theory is verified by FEM simulation results and prototype experiments. The difference between this method and other methods is also discussed. Compared with CT, this method adopts partial-gapped magnetic core and magnetic field sensor (MFS) for current reconstruction. When it works in rated state, this method is like a normal CT. Once the primary current saturated the small section core, it will be like a virtual gap, making the whole core more difficult to saturate and allowing the measurement of leakage flux. It has the advantages of simple and compact structure and can be embedded into the electronic current transformer (ECT) system. In this sense, it can have a good application prospect. The main limitation is the requirement of high permeability material for accuracy performance.

2 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BCBaichao Chen
Baichao Chen
ZZZhexuan Zhang
Zhexuan Zhang
YWYuwen Wu
Yuwen Wu
CTCuihua Tian
Cuihua Tian
YCYaojun Chen
Yaojun Chen
The direct current will cause the electromagnetic current transformer (CT) saturation, which will lead to the measurement error of some energy meters using CT for current sensing. This paper presents a novel anti DC bias energy meter. In the proposed approach, the magnetic-valve-type current transformer (MVCT) is used as the current sensor in the meter instead of conventional CT. As a result, the distorted secondary current can be fully compensated within MVCT when the core gets saturated. The principle of the new technology is described in detail. The simulations and experiments are performed to verify the correctness and feasibility of this novel energy meter when measuring load power consumption with DC bias.