Yaojun Chen

Yaojun Chen

Auto-generated profile, based on publicly available information

Yaojun Chen

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
YWYuwen Wu
Yuwen Wu
CTCuihua Tian
Cuihua Tian
ZZZhexuan Zhang
Zhexuan Zhang
BCBaichao Chen
Baichao Chen
SLShaojie Liu
Shaojie Liu
YCYaojun Chen
Yaojun Chen
If current transformer (CT) is saturated in operation, it will lead to incorrect current measurements and may cause relay maloperation, which can greatly threaten the safety of power grid. This paper analyzed the basic measuring characteristics of the proposed novel current transformer based on virtual air gap. This method can successfully compensate the distorted secondary current and expand the measuring range. Based on the simplified magnetization curve model, its working state is divided into linear working state, partially saturated working state and saturated state. Furthermore, its basic measuring characteristics are deducted theoretically. The theory is verified by FEM simulation results and prototype experiments. The difference between this method and other methods is also discussed. Compared with CT, this method adopts partial-gapped magnetic core and magnetic field sensor (MFS) for current reconstruction. When it works in rated state, this method is like a normal CT. Once the primary current saturated the small section core, it will be like a virtual gap, making the whole core more difficult to saturate and allowing the measurement of leakage flux. It has the advantages of simple and compact structure and can be embedded into the electronic current transformer (ECT) system. In this sense, it can have a good application prospect. The main limitation is the requirement of high permeability material for accuracy performance.

1 July 2015 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
ZBZhao Bin
Zhao Bin
HLHui Li
Hui Li
MWMingyu Wang
Mingyu Wang
CYChen Yaojun
Chen Yaojun
SLShengquan Liu
Shengquan Liu
Zhe ChenZhe Chen
Zhe Chen

2 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BCBaichao Chen
Baichao Chen
ZZZhexuan Zhang
Zhexuan Zhang
YWYuwen Wu
Yuwen Wu
CTCuihua Tian
Cuihua Tian
YCYaojun Chen
Yaojun Chen
The direct current will cause the electromagnetic current transformer (CT) saturation, which will lead to the measurement error of some energy meters using CT for current sensing. This paper presents a novel anti DC bias energy meter. In the proposed approach, the magnetic-valve-type current transformer (MVCT) is used as the current sensor in the meter instead of conventional CT. As a result, the distorted secondary current can be fully compensated within MVCT when the core gets saturated. The principle of the new technology is described in detail. The simulations and experiments are performed to verify the correctness and feasibility of this novel energy meter when measuring load power consumption with DC bias.

1 October 2018
Verified
Conference Paper
Closed access
MSMeng Sun
Meng Sun
BJBo Jing
Bo Jing
XJXiaoxuan Jiao
Xiaoxuan Jiao
YCYaojun Chen
Yaojun Chen
SSShuhao Si
Shuhao Si
YWYun Wang
Yun Wang
The airborne fuel pump as a typical high-reliability, long-life electromechanical component, its life prediction has problems such as small sample size and low prediction accuracy. Firstly, the degradation testing platform for airborne fuel pump is designed to obtain degradation data and life data. Secondly, a drift wiener process degradation model based on the combination of degradation data and life data is established. Finally, the life prediction is performed. The results show that predicted life of the airborne fuel pump, by the drift wiener process degradation model based on the combination of degradation data and life data, is closer to the true value and has higher accuracy, comparing to that by drift wiener process degradation model based on degenerate data.

1 January 2012
Verified
Conference Paper
Closed access
KJK. Jafri
K. Jafri
SYSong Zhong You
Song Zhong You
YCYaojun Chen
Yaojun Chen
BCB.C. Chen
B.C. Chen

24 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
BCBaichao Chen
Baichao Chen
WGWei Gao
Wei Gao
YCYaojun Chen
Yaojun Chen
CTCuihua Tian
Cuihua Tian
YZYuxiong Zhou
Yuxiong Zhou
GXGang Xue
Gang Xue
The input part of the high-voltage test power supply is usually composed of switching devices; however, the pulse-type periodic interference caused by the switching devices makes the monitoring of the test power supply partial discharge more difficult. Therefore, this paper proposes a high-efficiency and distortion-free linear power supply based on piecewise-linearization with all N-type transistor. Under the same DC input, multiple power transistors are connected to different taps of the same transformer. By controlling the period of linear conduction of each power transistor in turn, we ensure that the power transistor works on the linear side (biased towards saturation) to reduce its conduction voltage drop and the output realizes sinusoidal piecewise linearization, so that the converter can greatly improve the system efficiency. After that, from the perspective of the lowest sum of the transistor loss, an optimization method for the design of the multi-winding transformer ratio at each stage is proposed. Finally, a power supply prototype based on four-piece linear converter with an output voltage of 220 V was built. The experimental efficiency reaches 87.03%, and, additionally, if the linear amplification is divided into more sections, the efficiency can be further improved.