Bouras Ilyas

Bouras Ilyas

Auto-generated profile, based on publicly available information

Bouras Ilyas

El-Bez

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2026 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
KFKANOUNI Fares
KANOUNI Fares
MDMosbah Daamouche
Mosbah Daamouche
AMAhmed Mehaney
Ahmed Mehaney
MRMahdi Rahmani
Mahdi Rahmani
BIBouras Ilyas
Bouras Ilyas
BDBahram Djafari-Rouhani
Bahram Djafari-Rouhani
This work proposes a novel approach for the measurement of electrical conductivity in aqueous solutions of transition metal chlorides, specifically CuCl 2 –water, FeCl 3 –water, and NiCl 2 –water using a phononic–fluidic sensor. Indeed, it establishes a direct correlation between conductivity and the frequency of a cavity mode in the phononic crystal as a function of concentration. The phononic structure consists of air holes periodically distributed in a stainless-steel matrix. Meanwhile, the designed phononic crystal structure possesses a wide phononic band gap of width of 145 kHz that could be of a distinct effect through the detection process. By introducing a transition metal chlorides as defect in the central hole of the phononic crystal, the emergence of a resonant mode is expected which in turn represents the mainstay towards the detection of metal chlorides. In this regard, our findings investigated a significant shift in the spectral position of the resonant frequency with the concentration’s changes of metal chlorides, providing a superb sensitivity with respect to the concentration of 1.88 × 10 −4 (kHz ppm −1 ) for FeCl 3 solution, 1.80 × 10 −4 (kHz ppm −1 ) for NiCl 2 and 0.83 × 10 −4 (kHz ppm −1 ) for CuCl 2 . In addition, the highest figure of merit and quality factor values are obtained for FeCl 3 , which are 767.28 × 10 −7 ppm −1 and 162.75, respectively. Moreover, the lowest detection limits of the proposed sensor are 0.024 ppm for FeCl 3 , 0.039 ppm for NiCl 2 , and 0.061 ppm for CuCl 2 . In parallel, we performed direct electrical conductivity measurements for the same concentrations. A clear and consistent correlation between the resonant frequency and the electrical conductivity was observed. Based on this correlation, a calibration curve was established, enabling the indirect estimation of electrical conductivity from resonant frequency data. The sensor sensitivity with respect to electrical conductivity was found to be 0.1889 kHz (mS −1 cm −1 ) for FeCl 3 , 0.2056 kHz (mS −1 cm −1 ) for NiCl 2 , and 0.1548 kHz (mS −1 cm −1 ) for CuCl 2 .