João Paço Vaz De Souza

João Paço Vaz De Souza

Auto-generated profile, based on publicly available information

João Paço Vaz De Souza

Departamento de Ortopedia e Traumatologia, Instituto de Ortopedia e Traumatologia (IOT), Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Coluna/Columna
Verified
Journal Article
Open access
PDF file
TAThiego Pedro Freitas Araújo
Thiego Pedro Freitas Araújo
JSJoão Paz Vaz de Souza
João Paz Vaz de Souza
DMDiego Ubrig Munhoz
Diego Ubrig Munhoz
MJMauro Costa Morais Tavares Junior
Mauro Costa Morais Tavares Junior
RMRaphael Martus Marcon
Raphael Martus Marcon
OLOlavo Letaif
Olavo Letaif
Objective: Lumbosacral fixation presents problems in its arthrodesis, mainly due to pseudoarthrosis. Iliac screws minimize this problem, however, they show problems in the operative wound. The S2-Alar-iliac (S2AI) screw presents a lower rate of these complications. The anatomical differences between the populations and the sexes analyzed in the literature justify the study of the S2AI screw technique in Brazilian women. Methods: A total of 14 adult female CT scans were analyzed by 4 evaluators. Results: The mean bone length was 131.8 mm, the largest bone diameter was 22.6 mm, and the smallest bone diameter was 22.6 mm. Conclusions: The data presented are compatible with the literature and may assist spine surgeons in choosing the best implant and surgical technique. Level of Evidence I; Diagnostic Studies — Investigating a Diagnostic Test (anatomical investigation).

1 January 2019 in Clinics
Verified
Journal Article
Open access
PDF file
MJMauro Costa Morais Tavares Junior
Mauro Costa Morais Tavares Junior
DMDiego Ubrig Munhoz
Diego Ubrig Munhoz
JSJoão Paço Vaz De Souza
João Paço Vaz De Souza
RMRaphael Martus Marcon
Raphael Martus Marcon
ACAlexandre Fogaça Cristante
Alexandre Fogaça Cristante
OLOlavo Letaif
Olavo Letaif
The halo ring can be applied in children, through skeletal traction or a halo vest device, to treat many cervical spine pathologies, including traumatic injuries and pathologies related to deformities. However, the procedure is associated with various complications, such as infection, pin loosening, and respiratory and neurological problems. Although widely studied in adults, the best pin insertion site in children and the correlations of pin insertion sites with outcomes and complications have not been completely elucidated. This study aimed to determine alternative pin placement sites based on a morphological analysis of the infant skull by computerized tomography (CT). An analytical-descriptive study was performed using 50 CT scans from children. The Wilcoxon and Friedman tests were used. A linear and directly proportional relation was found between cranial thickness and patient age. The average thicknesses of the anterior points across all ages analyzed ranged from 4.16 mm to 4.98 mm. The thicknesses of the posterior points varied from 3.94 mm to 4.27 mm. Within each age range, points 1 cm above the standard insertion sites had thicknesses similar to those of the standard sites, and points 2 cm above the standard insertion sites had thicknesses greater than those of the standard sites. The cranial thickness at all points increases linearly with age. Points 1 and 2 cm above the standard insertion sites are viable alternatives for the placement of halo pins. Preoperative CT can aid in choosing the best positioning sites for pins in the skull.